A calibration method that simplifies and improves accurate determination of peptide molecular masses by MALDI-TOF MS

被引:75
作者
Gobom, J
Mueller, M
Egelhofer, V
Theiss, D
Lehrach, H
Nordhoff, E
机构
[1] Max Planck Inst Mol Genet, D-14195 Berlin, Germany
[2] Scienion AG, D-12489 Berlin, Germany
关键词
D O I
10.1021/ac011203o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of delayed ion extraction in MALDI time-of-flight mass spectrometry distorts the linear relationship between m/z and the square of the ion flight time (t(2)) With the consequence that, if a mass accuracy of 10 ppm or better is to be obtained, the calibrant signals have to fall close to the analyte signals. If this is not possible, systematic errors arise. To eliminate these, a higher-order calibration function and thus several calibrant signals are required. For internal calibration, however, this approach is limited by signal suppression effects and the increasing chance of the calibrant signals overlapping with analyte signals. If instead the calibrants are prepared separately, this problem is replaced by an other; i.e., the ion flight times are dependent on the sample plate position. For this reason, even if the calibrants are placed close to the sample, the mass accuracy is not improved when a higher-order calibration function is applied. We have studied this phenomenon and found that the relative errors, which result when moving from one sample to. the next, are directly proportional to m/z. Based on this observation, we developed a two-step calibration method,, that overcomes said limitations. The first step is an external calibration with a high-order polynomial function used for the determination,of the relation between m/z and t(2), and the second step is a first-order internal correction, for samples position-dependent errors. Applying this, method, sample position-dependent for instance, to a mass spectrum of a mixture of, 18 peptides from a tryptic digest of a recombinant protein resulted in an average mass error of 1.0 ppm with a standard deviation of 3.5 ppm When, instead using a conventional two-point internal calibration, the average relative error was 2.2 ppm,with a. standard deviation of 15 ppm. The new method is described and its performance is demonstrated with examples relevant to proteome research.
引用
收藏
页码:3915 / 3923
页数:9
相关论文
共 19 条
[1]   MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
BROWN, RS ;
LENNON, JJ .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1998-2003
[2]   IMPROVING THE RESOLUTION OF MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY BY EXPLOITING THE CORRELATION BETWEEN ION POSITION AND VELOCITY [J].
COLBY, SM ;
KING, TB ;
REILLY, JP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (11) :865-868
[3]   Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass measurement accuracy by using delayed extraction [J].
Edmondson, RD ;
Russell, DH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (10) :995-1001
[4]   Protein identification by MALDI-TOF-MS peptide mapping: A new strategy [J].
Egelhofer, V ;
Gobom, J ;
Seitz, H ;
Giavalisco, P ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1760-1771
[5]   Improvements in protein identification by MALDI-TOF-MS peptide mapping [J].
Egelhofer, V ;
Büssow, K ;
Luebbert, C ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2741-2750
[6]   α-cyano-4-hydroxycinnamic acid affinity sample preparation.: A protocol for MALDI-MS peptide analysis in proteomics [J].
Gobom, J ;
Schuerenberg, M ;
Mueller, M ;
Theiss, D ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :434-438
[7]   IDENTIFYING PROTEINS FROM 2-DIMENSIONAL GELS BY MOLECULAR MASS SEARCHING OF PEPTIDE-FRAGMENTS IN PROTEIN-SEQUENCE DATABASES [J].
HENZEL, WJ ;
BILLECI, TM ;
STULTS, JT ;
WONG, SC ;
GRIMLEY, C ;
WATANABE, C .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (11) :5011-5015
[8]   PROTEIN IDENTIFICATION BY MASS PROFILE FINGERPRINTING [J].
JAMES, P ;
QUADRONI, M ;
CARAFOLI, E ;
GONNET, G .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1993, 195 (01) :58-64
[9]   On the initial velocity of ions generated by matrix-assisted laser desorption ionization and its effect on the calibration of delayed extraction time-of-flight mass spectra [J].
Juhasz, P ;
Vestal, ML ;
Martin, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (03) :209-217
[10]   Applications of delayed extraction matrix-assisted laser desorption ionization time-of-flight mass spectrometry to oligonucleotide analysis [J].
Juhasz, P ;
Roskey, MT ;
Smirnov, IP ;
Haff, LA ;
Vestal, ML ;
Martin, SA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :941-946