STIR-Net: Deep Spatial-Temporal Image Restoration Net for Radiation Reduction in CT Perfusion

被引:21
作者
Xiao, Yao [1 ]
Liu, Peng [1 ]
Liang, Yun [1 ]
Stolte, Skylar [1 ]
Sanelli, Pina [2 ,3 ,4 ,5 ]
Gupta, Ajay [2 ]
Ivanidze, Jana [2 ]
Fang, Ruogu [1 ]
机构
[1] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[3] Northwell Hlth, Dept Radiol, Imaging Clin Effectiveness & Outcomes Res, Manhasset, NY USA
[4] Donald & Barbara Zucker Sch Med Hofstra Northwell, Hempstead, NY USA
[5] Feinstein Inst Med Res, Ctr Hlth Innovat & Outcomes Res, Manhasset, NY USA
基金
美国国家科学基金会;
关键词
CT perfusion image; radiation reduction; image restoration; deep learning; brain hemodynamics; PROJECTED CANCER-RISKS; HIGH-RESOLUTION IMAGE; X-RAY CT; SUPERRESOLUTION IMAGE; DOSE REDUCTION; ITERATIVE RECONSTRUCTION; UNITED-STATES; BRAIN; QUALITY; SPARSE;
D O I
10.3389/fneur.2019.00647
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Computed Tomography Perfusion (CTP) imaging is a cost-effective and fast approach to provide diagnostic images for acute stroke treatment. Its cine scanning mode allows the visualization of anatomic brain structures and blood flow; however, it requires contrast agent injection and continuous CT scanning over an extended time. In fact, the accumulative radiation dose to patients will increase health risks such as skin irritation, hair loss, cataract formation, and even cancer. Solutions for reducing radiation exposure include reducing the tube current and/or shortening the X-ray radiation exposure time. However, images scanned at lower tube currents are usually accompanied by higher levels of noise and artifacts. On the other hand, shorter X-ray radiation exposure time with longer scanning intervals will lead to image information that is insufficient to capture the blood flow dynamics between frames. Thus, it is critical for us to seek a solution that can preserve the image quality when the tube current and the temporal frequency are both low. We propose STIR-Net in this paper, an end-to-end spatial-temporal convolutional neural network structure, which exploits multi-directional automatic feature extraction and image reconstruction schema to recover high-quality CT slices effectively. With the inputs of low-dose and low-resolution patches at different cross-sections of the spatio-temporal data, STIR-Net blends the features from both spatial and temporal domains to reconstruct high-quality CT volumes. In this study, we finalize extensive experiments to appraise the image restoration performance at different levels of tube current and spatial and temporal resolution scales.The results demonstrate the capability of our STIR-Net to restore high-quality scans at as low as 11% of absorbed radiation dose of the current imaging protocol, yielding an average of 10% improvement for perfusion maps compared to the patch-based log likelihood method.
引用
收藏
页数:16
相关论文
共 60 条
[1]   CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Villablanca, J. P. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1632-1639
[2]  
AIZAWA K, 1991, P SOC PHOTO-OPT INS, V1605, P318, DOI 10.1117/12.50221
[3]  
Ali M, 2014, 2014 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (ICSPCC), P184, DOI 10.1109/ICSPCC.2014.6986179
[4]  
[Anonymous], 2012, Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
[5]   Flow Fields: Dense Correspondence Fields for Highly Accurate Large Displacement Optical Flow Estimation [J].
Bailer, Christian ;
Taetz, Bertram ;
Stricker, Didier .
2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, :4015-4023
[6]  
Baxes G. A., 1994, DIGITAL IMAGE PROCES
[7]  
Benjamin EJ, 2017, CIRCULATION, V135, pE146, DOI [10.1161/CIR.0000000000000485, 10.1161/CIR.0000000000000558, 10.1161/CIR.0000000000000530]
[8]   Addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain [J].
Britten, AJ ;
Crotty, M ;
Kiremidjian, H ;
Grundy, A ;
Adam, EJ .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) :323-328
[9]   External Patch Prior Guided Internal Clustering for Image Denoising [J].
Chen, Fei ;
Zhang, Lei ;
Yu, Huimin .
2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, :603-611
[10]   Proposing a Simple Radiation Scale for the Public: Radiation Index [J].
Cho, Gyuseong ;
Kim, Jong Hyun ;
Park, Tae Soon ;
Cho, Kunwoo .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (03) :598-608