Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors

被引:49
作者
Perez-Guaita, David [1 ]
Kokoric, Vjekoslav [2 ]
Wilk, Andreas [2 ]
Garrigues, Salvador [1 ]
Mizaikoff, Boris [2 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
[2] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
关键词
hollow waveguide; substrate-integrated hollow waveguide; iHWG; mid-infrared; MIR; isoprene; breath analysis; EXHALED MOUSE BREATH; GAS SENSORS; BIOMARKERS; OZONE; BLOOD;
D O I
10.1088/1752-7155/8/2/026003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 mu m) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath was coupled to an iHWG serving simultaneously as highly miniaturized gas cell and light conduit in combination with a compact Fourier transform infrared spectrometer. A gas mixing system enabled extensive system calibration using isoprene standards. After system optimization, a calibration function obtaining a limit of quantification of 106 ppb was achieved. According to the literature, the obtained sensitivity is sufficient for quantifying middle to high isoprene concentrations occurring in exhaled breath. Finally, a volunteer breath sample was analysed proving comparable values of isoprene in a real-world scenario. Despite its fundamental utility, the proposed methodology contains some limitations in terms of sensitivity and temporal resolution in comparison with the readily available measurement techniques that should be addressed during future optimization of the system. Nonetheless, this study presents the first determination of endogenous VOCs in breath via advanced hollow waveguide MIR sensor technology, clearly demonstrating its potential for the analysis of volatile biomarkers in exhaled breath.
引用
收藏
页数:8
相关论文
共 36 条
  • [1] MEMS-Based Selective Preconcentration of Trace Level Breath Analytes
    Alfeeli, Bassam
    Agah, Masoud
    [J]. IEEE SENSORS JOURNAL, 2009, 9 (09) : 1068 - 1075
  • [2] The versatile use of exhaled volatile organic compounds in human health and disease
    Boots, Agnes W.
    van Berkel, Joep J. B. N.
    Dallinga, Jan W.
    Smolinska, Agnieszka
    Wouters, Emile F.
    van Schooten, Frederik J.
    [J]. JOURNAL OF BREATH RESEARCH, 2012, 6 (02)
  • [3] Investigation of lung cancer biomarkers by hyphenated separation techniques and chemometrics
    Buszewski, Boguslaw
    Ulanowska, Agnieszka
    Kowalkowski, Tomasz
    Cieslinski, Krzysztof
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (03) : 573 - 581
  • [4] BLOOD ISOPRENE CONCENTRATIONS IN HUMANS AND IN SOME ANIMAL SPECIES
    CAILLEUX, A
    COGNY, M
    ALLAIN, P
    [J]. BIOCHEMICAL MEDICINE AND METABOLIC BIOLOGY, 1992, 47 (02): : 157 - 160
  • [5] Laser spectroscopy on volatile sulfur compounds: possibilities for breath analysis
    Ciaffoni, L.
    Peverall, R.
    Ritchie, G. A. D.
    [J]. JOURNAL OF BREATH RESEARCH, 2011, 5 (02)
  • [6] Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time
    da Silveira Petruci, Joao Flavio
    Fortes, Paula Regina
    Kokoric, Vjekoslav
    Wilk, Andreas
    Raimundo, Ivo Milton, Jr.
    Cardoso, Arnaldo Alves
    Mizaikoff, Boris
    [J]. ANALYST, 2014, 139 (01) : 198 - 203
  • [7] Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
    da Silveira Petruci, Joao Flavio
    Fortes, Paula Regina
    Kokoric, Vjekoslav
    Wilk, Andreas
    Raimundo, Ivo Milton, Jr.
    Cardoso, Arnaldo Alves
    Mizaikoff, Boris
    [J]. SCIENTIFIC REPORTS, 2013, 3
  • [8] Breath biomarkers of liver cirrhosis
    Dadamio, Jesica
    Van den Velde, Sandra
    Laleman, Wim
    Van Hee, Paul
    Coucke, Wim
    Nevens, Frederik
    Quirynen, Marc
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 905 : 17 - 22
  • [9] Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy
    Dahnke, H
    Kleine, D
    Hering, P
    Mürtz, M
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (08): : 971 - 975
  • [10] Human breath emissions of VOCs
    Fenske, JD
    Paulson, SE
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (05) : 594 - 598