Standardization and harmonization in hematology: Instrument alignment, quality control materials, and commutability issue

被引:1
作者
Vidali, Matteo [1 ]
Carobene, Anna [2 ]
Apassiti Esposito, Sara [3 ]
Napolitano, Gavino [3 ]
Caracciolo, Alessandra [3 ]
Seghezzi, Michela [3 ]
Previtali, Giulia [3 ]
Lippi, Giuseppe [4 ]
Buoro, Sabrina [3 ]
机构
[1] Maggiore Carita Hosp, Clin Chem Unit, Novara, Italy
[2] Osped San Raffaele, Lab Med, Milan, Italy
[3] Hosp Papa Giovanni XXIII, Clin Chem Lab, Bergamo, Italy
[4] Univ Verona, Sect Clin Biochem, Verona, Italy
关键词
alignment; analytical quality; commutability; control material; hematologic analyzers; WORKING GROUP RECOMMENDATIONS; BLOOD-CELL COUNTS; BIOLOGICAL VARIATION; PARAMETERS; PERFORMANCE; HAEMIGLOBINCYANIDE; SPECIFICATIONS; VERIFICATION; LEUKOCYTES; PROTOCOL;
D O I
10.1111/ijih.13379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction In the hub and spoke laboratory network, the number of hematology analyzers (HAs) within each core center has increased, and the control of HAs alignment is becoming necessary requirement to ensure analytical quality. In this scenario, HA alignment can be assessed by analyzing the same control material used for internal quality control on multiple HAs, assuming its commutability. The aim of the study was to verify the applicability of a protocol for the alignment of HAs based on control material rather than on fresh whole-blood samples. Methods The alignment of five HAs was evaluated for red (RBC, Hb, MCV, RET), white (WBC, NE, LY, MO, EO, BA, IG), and platelet (PLT) series parameters, following a protocol by SIBioC, using human sample (HS) and quality control material (QC), after the verification of commutability, according to the IFCC protocol. Maximum bias was derived from biological variation data. Results A complete alignment between instruments was confirmed for the majority of the parameters investigated both for HS and QC material. Partial misalignments or inconcludent results were instead evident for MCV, MO, EO, BA, and IG. Interestingly, QC material was found to be not commutable for LY, MO, and BA. Conclusion The alignment of hematologic analyzers for main cell population parameters may be verified with both QC and HS, displaying consistent results and interpretation. The evaluation for some white series parameters (EO, BA, and IG) is critical, and particular attention must be paid to the values of the material used for the alignment.
引用
收藏
页数:8
相关论文
共 40 条
  • [1] [Anonymous], 151892013 ISO
  • [2] [Anonymous], 2000, H15A3 CLSI
  • [3] Performance evaluation of the Sysmex haematology XN modular system
    Briggs, Carol
    Longair, Ian
    Kumar, Punamar
    Singh, Deepak
    Machin, Samuel J.
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2012, 65 (11) : 1024 - 1030
  • [4] Commutability of a Whole-Blood External Quality Assessment Material for Point-of-Care C-Reactive Protein, Glucose, and Hemoglobin Testing
    Bukve, Tone
    Sandberg, Sverre
    Vie, Wenche S.
    Solvik, Una
    Christensen, Nina G.
    Stavelin, Anne
    [J]. CLINICAL CHEMISTRY, 2019, 65 (06) : 791 - 797
  • [5] Short- and medium-term biological variation estimates of red blood cell and reticulocyte parameters in healthy subjects
    Buoro, Sabrina
    Carobene, Anna
    Seghezzi, Michela
    Manenti, Barbara
    Dominoni, Paola
    Pacioni, Aurelio
    Ceriotti, Ferruccio
    Ottomano, Cosimo
    Lippi, Giuseppe
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (06) : 954 - 963
  • [6] Short- and medium-term biological variation estimates of leukocytes extended to differential count and morphology-structural parameters (cell population data) in blood samples obtained from healthy people
    Buoro, Sabrina
    Carobene, Anna
    Seghezzi, Michela
    Manenti, Barbara
    Pacioni, Aurelio
    Ceriotti, Ferruccio
    Ottomano, Cosimo
    Lippi, Giuseppe
    [J]. CLINICA CHIMICA ACTA, 2017, 473 : 147 - 156
  • [7] Biological variation of platelet parameters determined by the Sysmex XN hematology analyzer
    Buoro, Sabrina
    Seghezzi, Michela
    Manenti, Barbara
    Pacioni, Aurelio
    Carobene, Anna
    Ceriotti, Ferruccio
    Ottomano, Cosimo
    Lippi, Giuseppe
    [J]. CLINICA CHIMICA ACTA, 2017, 470 : 125 - 132
  • [8] Quality specification in haematology: the automated blood cell count
    Buttarello, M
    [J]. CLINICA CHIMICA ACTA, 2004, 346 (01) : 45 - 54
  • [9] Automated blood cell counts - State of the art
    Buttarello, Mauro
    Plebani, Mario
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (01) : 104 - 116
  • [10] A very uncommon haemoglobin value resulting from a severe acute malnutrition in a 16-month-old child in Ethiopia
    Carobene, Anna
    Kiarie, Annette Gathoni
    Tsegaye, Mizan
    Seghezzi, Michela
    Buoro, Sabrina
    Mburugu, Ritah Wanja
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) : E103 - E105