Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates

被引:169
作者
Brunet, S
Leblanc, M
Geadah, D
Parent, D
Courteau, S
Cardinal, J
机构
[1] Hop Maison Neuve Rosemont, Dept Nephrol, Intens Care Unit, Montreal, PQ H1T 2M4, Canada
[2] Hop Maison Neuve Rosemont, Dept Biochem, Intens Care Unit, Montreal, PQ H1T 2M4, Canada
[3] Univ Montreal, Montreal Heart Inst, Montreal, PQ, Canada
关键词
continuous renal replacement therapy; convection; diffusion; predilution; clearances; beta(2)-microglobulin;
D O I
10.1016/S0272-6386(99)70076-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Clearances of several solutes (urea, creatinine, phosphate, urates, beta(2)-microglobulin [beta(2)-M]) were measured during venovenous continuous renal replacement therapy (CRRT) at Various ultrafiltration (Q(UF); 0 to 2 L/h) and dialysate flow rates (Q(D); 0 to 2.5 L/h). Preset Multiflow-60 and Multiflow-100 hollow-fiber dialysers (M-60 and M-100; Hospal-Gambro, St-Leonard, Canada) were compared (five patients for each type). First, we evaluated the impact of predilution on convective clearances: a progressive decrease in patient clearances, similar for both filters, was observed, reaching a maximum of 15%, 18%, and 19% for urea, urates, and creatinine, respectively, with predilution at a Q(UF) of 2 L/h. Second, we compared convective and diffusive clearances. Because effluent to plasma ratio (E/P) remained at 1 for small solutes (urea, creatinine, phosphate, urates) during convection, clearances were equal to the effluent rate for both dialyzers. However, we observed greater diffusive clearances for small molecules with M-100 than with M-60 at a Q(D) of 1.5 to 2.5 L/h, the difference being more significant as molecular weight increased. For beta(2)-M, diffusive clearance was very low and rapidly reached a plateau of 8 and 12 mL/min for M-60 and M-100, respectively at a Q(D) greater than 1.5 L/h. Convective clearances for beta(2)-M increased nonlinearly up to 20 +/- 2 mL/min at a progressively greater Q(UP) (from 0.5 to 2 L/h) for both M-60 and M-100. This nonlinear increase was attributed to an increase of almost 40% in UP for beta(2)-M from a Q(UF) of 0.5 to 2 L/h. Third, the interaction between convection and diffusion was assessed by measuring solute clearances at a fixed Q(UF) (1 and 2 L/h) and variable Q(D) (0.5 to 2.5 L/h). For small molecules, no significant interaction between convection and diffusion was noticed with M-100, whereas only a small interaction was noticed with M-60. However, for beta(2)-M, the addition of diffusion (Q(D), 0.5 to 2.5 L/h) did not result in any significant increase in total clearances over convective clearances for M-60 and M-100. This observation suggests that the diffusive clearances for Sp-M observed with M-60 and M-100 at a Q(UF) of 0 L/h and at various Q(D) probably occurs by convective fluxes across the membrane. These results demonstrate that convection is more efficient than diffusion in removing mixed-molecular-weight solutes during CRRT. (C) 1999 by the National Kidney Foundation, Inc.
引用
收藏
页码:486 / 492
页数:7
相关论文
共 15 条
[1]  
Bellomo R, 1998, KIDNEY INT, V53, pS182
[2]  
Clark D, 1997, COMPUTER, V30, P14, DOI [10.1109/2.625291, 10.1109/2.587543]
[3]  
Clark WR, 1998, KIDNEY INT, V53, pS133
[4]   Renal replacement therapy quantification in acute renal failure [J].
Clark, WR ;
Mueller, BA ;
Kraus, MA ;
Macias, WL .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 :86-90
[5]   PLASMA-PROTEIN ADSORPTION TO HIGHLY PERMEABLE HEMODIALYSIS MEMBRANES [J].
CLARK, WR ;
MACIAS, WL ;
MOLITORIS, BA ;
WANG, NHL .
KIDNEY INTERNATIONAL, 1995, 48 (02) :481-488
[6]  
Clark WR, 1997, J AM SOC NEPHROL, V8, P804
[7]  
CLARK WR, 1997, ADV REN REPLACE T S1, V4, pS64
[8]   Urea kinetic modeling for CRRT [J].
Garred, L ;
Leblanc, M ;
Canaud, B .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (05) :S2-S9
[9]  
GOLDFARB S, 1994, J AM SOC NEPHROL, V5, P228
[10]  
Golper T A, 1994, ASAIO J, V40, P936, DOI 10.1097/00002480-199410000-00006