A sensitive liquid chromatography-tandem mass spectrometry method for quantitative determination of dasotraline in human plasma and its clinical application

被引:1
|
作者
Skende, Estela [1 ]
Zheng, Nancy [2 ]
Chen, Yu-Luan [1 ]
机构
[1] Sunov Pharmaceut Inc, Bioanalyt Sci, 84 Waterford Dr, Marlborough, MA 01752 USA
[2] PPD Bioanalyt Lab, 3230 Deming Way, Middleton, WI 53562 USA
关键词
Dasotraline; Method development and validation; Pharmacokinetics; Attention deficit hyperactivity disorder (ADHD); Binge eating disorder (BED); ATTENTION-DEFICIT/HYPERACTIVITY DISORDER; ACTIVE METABOLITE; SERTRALINE; PLACEBO; MS;
D O I
10.1016/j.jpba.2020.113611
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This manuscript describes a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of dasotraline in human plasma. Dasotraline and the internal standard (IS) d(4)-C-13(4)-dasotraline were extracted from the 0.500-mL plasma pre-mixed with 0.20-mL of 0.5 M sodium bicarbonate solution by a 3-mL of hexane containing 0.7 % sec-butyl alcohol. The organic extract, after dried down, was reconstituted in 150 mu L acetonitrile containing 0.1 % formic acid. Forty (40) mu L of the resulted sample was injected into LC-MS/MS for analysis. Chromatographic separation was on a Betasil Silica column. MS/MS detection was by monitoring m/z 275 -> 59 and 283 -> 60 for dasotraline and IS, respectively. Peak area ratio of analyte/IS was used for constructing calibration curve and calculating sample concentration. The retention time was similar to 3.1 min for both dasotraline and IS. The validated linear range was 5-5000 pg/mL with correlation coefficient r >= 0.999. Intra-run precision and accuracy were <= 7.3 % CV (n = 6) and 94.4-101.0 % of nominals. Inter-run precision and accuracy were <= 4.7 % CV (n = 18) and 96.1-99.8 % of nominals. Plasma sample was confirmed stable for 8 cycles of freeze/thaw, 29 h on bench-top, and up to 977 days of storage at both -20 degrees C and -70 degrees C. This method was successfully applied to analyze pharmacokinetic (PK) samples from a single ascending dose (SAD) clinical study with healthy subjects. PK results indicated that dasotraline was slowly absorbed (t(max): 10-12 h) and slowly eliminated (terminal elimination half-life, i.e. t(1/2): 47-77 h) with dose proportional C-max but slightly greater than dose proportional AUC with increase of dosed amount. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Determination of zolpidem in human plasma by liquid chromatography-tandem mass spectrometry for clinical application
    Byeon, Ji-Yeong
    Lee, Hye-In
    Lee, Yun-Jeong
    Lee, Jung-Eun
    Kim, Se-Hyung
    Kim, Young-Hoon
    Na, Han-Sung
    Jang, Choon-Gon
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 129 - 134
  • [2] Rapid and sensitive determination of vinorelbine in human plasma by liquid chromatography-tandem mass spectrometry and its pharmacokinetic application
    Qian, Jun
    Wang, Yixuan
    Chang, Jianhua
    Zhang, Jian
    Wang, Jialei
    Hu, Xichun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10): : 662 - 668
  • [3] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of scutellarin in human plasma: Application to a pharmacokinetic study
    Yulan, S
    Fang, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 1 - 5
  • [4] Validated liquid chromatography-tandem mass spectrometry method for quantitative determination of dauricine in human plasma and its application to pharmacokinetic study
    Liu, Xiaoying
    Liu, Qian
    Wang, Dongmei
    Wang, Xueya
    Zhang, Peng
    Xu, Haiyan
    Zhao, Hui
    Zhao, Huaiqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1199 - 1203
  • [5] Liquid chromatography-tandem mass spectrometry method for the determination of propranolol in human plasma and its application to a bioequivalence study
    do Carmo Borges, Ney Carter
    Rigato, Hamilton Modesto
    de Oliveira, Paulo Renato
    Nogueira, Daniele Rubert
    Moreno, Ronilson Agnaldo
    Dalmora, Sergio Luiz
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (19) : 2927 - 2941
  • [6] Determination of daptomycin in human plasma by liquid chromatography-tandem mass spectrometry. Clinical application
    Verdier, Marie-Clemence
    Bentue-Ferrer, Daniele
    Tribut, Olivier
    Collet, Nicolas
    Revest, Matthieu
    Bellissant, Eric
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (01) : 69 - 75
  • [7] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Trimetazidine in Human Plasma
    Zou, Jianjun
    Dai, Li
    Wang, Guang Ji
    Zhu, Yubing
    Fan, Hongwei
    Xiao, Da Wei
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2008, 58 (09): : 429 - 434
  • [8] Quantitative Determination of Amitriptyline and Its Metabolite in Rat Plasma by Liquid Chromatography-tandem Mass Spectrometry
    Chae, Jung-woo
    Baek, In-hwan
    An, Jung-hwa
    Kim, Eun Jung
    Kwon, Kwang-il
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (07) : 2163 - 2167
  • [9] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the determination of metoclopramide in human plasma: application to a bioequivalence study
    Inamadugu, Jaswanth Kumar
    Damaramadugu, Rajasekhar
    Mullangi, Ramesh
    Ponneri, Venkateswarlu
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 1006 - 1014
  • [10] Liquid chromatography-tandem mass spectrometry method for determination of rivaroxaban in human plasma and its application to a pharmacokinetic study
    Shaikh, Khurshid
    Mungantiwar, Ashish
    Halde, Supriya
    Pandita, Nancy
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2020, 26 (02) : 91 - 105