Smart watch accelerometry for analysis and diagnosis of tremor

被引:115
作者
Wile, Daryl J. [1 ]
Ranawaya, Ranjit [1 ]
Kiss, Zelma H. T. [1 ]
机构
[1] Univ Calgary, Dept Clin Neurosci, Hotchkiss Brain Inst, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Tremor; Parkinson's disease; Essential tremor; Accelerometry; PARKINSONS-DISEASE;
D O I
10.1016/j.jneumeth.2014.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Distinguishing the postural re-emergent tremor of Parkinson disease from essential tremor can be difficult clinically. Use of accelerometry to aid diagnosis is limited to laboratory settings. We sought to record and differentiate these tremors using a smart watch device in an outpatient clinic. New method: 41 patients were enrolled. Recordings were made with a smart watch device on the predominantly affected hand (all patients), and simultaneously with an analog accelerometer (10 patients) with hands at rest and outstretched. Tremor peak frequency, peak power, and power of the first four harmonics was calculated and compared between the two devices. Mean power at the first four harmonics was calculated and used to classify tremor as parkinsonian or essential. Test characteristics were calculated to compare the device and clinical diagnoses. Results: Mean harmonic peak power was both highly sensitive and specific for distinction of Parkinson disease postural tremor from essential tremor with an optimal threshold for our sample (sensitivity 90.9%, 95% CI 58.7-99.8%; specificity 100%, 95% CI 76.8-100%; Cohen's kappa = 0.91, SE = 0.08). Comparison with existing methods: The smart watch and analog devices had nearly perfect concordance of peak frequency and proportional harmonic power. The smart watch recordings in clinic took 3-6 min. Conclusions: A smart watch device can provide accurate and diagnostically relevant information about postural tremor. Its portability and ease of use could help translate such techniques into routine clinic use or to the community. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 13 条
[1]   The contribution of tremor studies to diagnosis of Parkinsonian and essential tremor: a statistical evaluation [J].
Burne, JA ;
Hayes, MW ;
Fung, VSC ;
Yiannikas, C ;
Boljevac, D .
JOURNAL OF CLINICAL NEUROSCIENCE, 2002, 9 (03) :237-242
[2]   Long duration asymmetrical postural tremor is likely to predict development of Parkinson's disease and not essential tremor: clinical follow up study of 13 cases [J].
Chaudhuri, KR ;
Buxton-Thomas, M ;
Dhawan, V ;
Peng, R ;
Meilak, C ;
Brooks, DJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2005, 76 (01) :115-117
[3]   Rest tremor in patients with essential tremor - Prevalence, clinical correlates, and electrophysiologic characteristics [J].
Cohen, O ;
Pullman, S ;
Jurewicz, E ;
Watner, D ;
Louis, ED .
ARCHIVES OF NEUROLOGY, 2003, 60 (03) :405-410
[4]   Using a smart phone as a standalone platform for detection and monitoring of pathological tremors [J].
Daneault, Jean-Francois ;
Carignan, Benoit ;
Codere, Carl Eric ;
Sadikot, Abbas F. ;
Duval, Christian .
FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 6 :1-31
[5]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[6]   SAMPLE-SIZE DETERMINATIONS FOR THE 2 RATER-KAPPA STATISTIC [J].
FLACK, VF ;
AFIFI, AA ;
LACHENBRUCH, PA ;
SCHOUTEN, HJA .
PSYCHOMETRIKA, 1988, 53 (03) :321-325
[7]   Are We Making Progress in the Understanding of Tremor in Parkinson's Disease? [J].
Hallett, Mark ;
Deuschl, Guenther .
ANNALS OF NEUROLOGY, 2010, 68 (06) :780-781
[8]   Common misdiagnosis of a common neurological disorder - How are we misdiagnosing essential tremor? [J].
Jain, Samay ;
Lo, Steven E. ;
Louis, Elan D. .
ARCHIVES OF NEUROLOGY, 2006, 63 (08) :1100-1104
[9]   Rapid tremor frequency assessment with the iPhone accelerometer [J].
Joundi, Raed A. ;
Brittain, John-Stuart ;
Jenkinson, Ned ;
Green, Alexander L. ;
Aziz, Tipu .
PARKINSONISM & RELATED DISORDERS, 2011, 17 (04) :288-290
[10]   ASSAY VALIDATION USING THE CONCORDANCE CORRELATION-COEFFICIENT [J].
LIN, LIK .
BIOMETRICS, 1992, 48 (02) :599-604