Comparison of the BANGkit™ and the PRESAGE™ gel dosimeters for use with a CCD-based optical CT scanner

被引:4
作者
Chang, Kyung Hwan [1 ]
Lee, Suk [1 ]
Cao, Yuan Jie [1 ]
Shim, Jang Bo [1 ]
Lee, Ji Eun [1 ]
Lee, Nam Kwon [1 ]
Lee, Jung Ae [1 ]
Yang, Dae Sik [1 ]
Park, Young Je [1 ]
Yoon, Won Sup [1 ]
Kim, Chul Yong [1 ]
Cho, Sam Ju [2 ]
Lee, Sang Hoon [3 ,4 ]
Kim, Woo Chul [5 ]
Min, Chul Kee [5 ]
Cho, Kwang Hwan [5 ]
Huh, Hyun Do [6 ]
机构
[1] Korea Univ, Dept Radiat Oncol, Coll Med, Seoul 130701, South Korea
[2] Eulji Univ, Dept Radiol Sci, Songnam 461713, South Korea
[3] Cheil Gen Hosp, Dept Radiat Oncol, Seoul 100380, South Korea
[4] Kwandong Univ, Coll Med, Womens Healthcare Ctr, Seoul 100380, South Korea
[5] Soonchunhyang Univ Hosp, Dept Radiat Oncol, Puchon 420767, South Korea
[6] Inha Univ Hosp, Dept Radiat Oncol, Inchon 400711, South Korea
关键词
BANGkit (TM) gel dosimeter; PRESAGE (TM) gel dosimeter; Spectrophotometer; Radiological properties; Optical CT scanner;
D O I
10.3938/jkps.64.740
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We compared the basic characteristics of two commercially-available scattering gel (BANGkit (TM)) and non-scattering gel (PRESAGE (TM)) dosimeters with a spectrophotometer to investigate each device's dosimetric properties. The two types of gel dosimeters were spectrophotometrically analyzed. For each gel dosimeter, the absorbance, dose linearity, reproducibility, dose rate dependency, and oxygen effect were evaluated at various wavelengths and doses. The best dose linearities of the BANGkit (TM) and the PRESAGE (TM) gel dosimeters gave R2 values of 0.97 and 0.98 at wavelengths of 485 nm and 600 nm, respectively, over the range of doses. The BANGkit (TM) gel showed no peak sensitivity within the studied range of wavelengths whereas the PRESAGE (TM) gel demonstrated peak sensitivity at a wavelength of 630 nm. The reproducibilities and the dose-rate dependences of the two gel dosimeters were within the range of +/- 2% and +/- 3%, respectively. We have shown that the peak sensitivities of the two gel dosimeters were significantly different; the BANGkit (TM) gel showed no peak sensitivity within the studied range of wavelengths whereas the PRESAGE (TM) gel demonstrated a peak sensitivity at a wavelength of 630 nm. We have confirmed that the radiochromic gel dosimeter was appropriate for use with a CCD-based optical CT scanner.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 20 条
[1]   Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation [J].
Adamovics, J. ;
Maryanski, M. J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :107-112
[2]  
Adamovics J., 2004, Journal of Physics: Conference Series, V3, P172, DOI 10.1088/1742-6596/3/1/020
[3]   Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer [J].
Ashamalla, Hani ;
Tejwani, Ajay ;
Parameritis, Ioannis ;
Swamy, Uma ;
Luo, Pei Ching ;
Guirguis, Adel ;
Lavaf, Amir .
RADIATION ONCOLOGY JOURNAL, 2013, 31 (02) :104-110
[4]   Spectrophotometric determination of the optimal wavelength for a polymer-gel dosimeter [J].
Chang, Kyung Hwan ;
Lee, Suk ;
Cao, Yuan Jie ;
Shim, Jang Bo ;
Lee, Jung Ae ;
Yang, Dae Sik ;
Park, Young Je ;
Yoon, Won Sup ;
Kim, Chul Yong ;
Cho, Sam Ju ;
Lee, Sang Hoon ;
Kim, Woo Chul ;
Min, Chul Kee ;
Cho, Kwang Hwan ;
Huh, Hyun Do .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (08) :1194-1198
[5]   Development of a novd normoxic polymer gel dosimeter (TENOMAG) [J].
Cho, Sam Ju ;
Shin, Dongho ;
Do Huh, Hyun ;
Lee, Sang Hoon ;
Lim, Sang Wook ;
Jang, Jisun ;
Cho, Kwang Hwan ;
Shin, Hun Joo ;
Kwon, Sooil ;
Yun, Hyong Geun ;
Yun, Sang Mo ;
Shin, Dong Oh ;
Yang, Dae Sik ;
Park, Young Je ;
Kim, Chul Yong ;
Lee, Suk .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (05) :1798-1804
[6]   The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels [J].
De Deene, Y ;
Vergote, K ;
Claeys, C ;
De Wagter, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03) :653-673
[7]  
De Deene Y., 2004, Journal of Physics: Conference Series, V3, P34, DOI 10.1088/1742-6596/3/1/006
[8]  
De Deene Y, 2002, PHYS MED BIOL, V47, P3441, DOI 10.1088/0031-9155/47/19/301
[9]   Characterization of a new radiochromic three-dimensional dosimeter [J].
Guo, P. Y. ;
Adamovics, J. A. ;
Oldham, M. .
MEDICAL PHYSICS, 2006, 33 (05) :1338-1345
[10]  
손기홍, 2013, [PROGRESS in MEDICAL PHYSICS, 의학물리], V24, P154, DOI 10.14316/pmp.2013.24.3.154