Future of active catheters

被引:67
作者
Lim, G
Park, K
Sugihara, M
Minami, K
Esashi, M
机构
[1] Faculty of Engineering, Tohoku University, Sendai
关键词
active catheters; shape memory alloy;
D O I
10.1016/0924-4247(96)01279-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A prototype of a catheter that can move like a snake, incorporating distributed shape memory alloy (SMA) actuators, a related device (built-in circuit) and techniques (laser CVD) are described. The outer diameter of the active catheter is 2.8 mm and it has many links fabricated using three-dimensional silicon micromachining. A silicon batch process is used for the fabrication of a link to minimize the assembly work. Problems that may occur in the fabrication of active catheters in the future are discussed and possible solutions are suggested. To minimize the number of lead wires in an active catheter that has many distributed SMA actuators, a packaged signal-processing IC for communication and control purposes has been developed. A new heating method (indirect heating), which is necessary for mounting IC chips on a link, has been developed. A micro assembly process that uses polymer as adhesive, deposited by laser CVD, has been studied to develop the future generation of smaller active catheters.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 12 条
[1]   TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION [J].
DOTTER, CT ;
JUDKINS, MP .
CIRCULATION, 1964, 30 (05) :654-&
[2]  
Esashi M., 1992, Proceedings. IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots(Cat. No.92CH3093-2), P43, DOI 10.1109/MEMSYS.1992.187688
[3]  
Haga Y., 1994, 12 SENS S, P135
[4]  
Kaneko S., 1995, P INT S MICR INT MAT, P87
[5]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
LEVY, RI ;
MOCK, MB ;
WILLMAN, VL ;
FROMMER, PL .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (02) :101-103
[6]  
LIM G, 1994, 12 SENS S JAP 2 3 JU, P78
[7]  
LIM G, 1995, P IEEE MEMS WORKSH, P116
[8]   Active endoscope with SMA (shape memory alloy) coil springs [J].
Maeda, S ;
Abe, K ;
Yamamoto, K ;
Tohyama, O ;
Ito, H .
NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, :290-295
[9]  
PARK KT, 1995, 6 C SENS TECHN KOR 1, P510
[10]   A NEW CATHETER SYSTEM FOR CORONARY ANGIOPLASTY [J].
SIMPSON, JB ;
BAIM, DS ;
ROBERT, EW ;
HARRISON, DC .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (05) :1216-1222