Open-Circuit Fault-Tolerant Control for Outer Switches of Three-Level Rectifiers in Wind Turbine Systems

被引:57
作者
Lee, June-Seok [1 ]
Lee, Kyo-Beum [1 ]
机构
[1] Ajou Univ, Dept Elect & Comp Engn, Suwon 443749, South Korea
基金
新加坡国家研究基金会;
关键词
Neutral-point-clamped rectifier; open-circuit fault; open-switch fault; reliability; three-level topology; tolerant control; T-type rectifier; NEUTRAL-POINT VOLTAGE; CONVERTER; RELIABILITY; PERFORMANCE; IMPROVEMENT; MODULATION; GENERATION; INVERTER; BALANCE;
D O I
10.1109/TPEL.2015.2464803
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A three-level converter is used as the power converters of wind turbine systems because of their advantages such as low-current total harmonic distortion, high efficiency, and low collector-emitter voltage. Interior permanent magnet synchronous generators (IPMSGs) have been chosen as the generator in wind turbine systems owing to their advantages of size and efficiency. In wind turbine systems consisting of the three-level converter and the IPMSG, fault-tolerant controls for an open-circuit fault of switches should be implemented to improve reliability. This paper focuses on the open-circuit fault of outer switches (S-x1 and S-x4) in three-level rectifiers (both neutral-point clamped and T-type) that are connected to the IPMSG. In addition, the effects of S-x1 and S-x4 open-circuit faults are analyzed, and based on this analysis, a tolerant control is proposed. The proposed tolerant control maintains normal operation with sinusoidal currents under the open-circuit fault of outer switches by adding a compensation value to the reference voltages. The effectiveness and performance of the proposed tolerant control are verified by simulation and experiment.
引用
收藏
页码:3806 / 3815
页数:10
相关论文
共 23 条
[1]   Performance Evaluation of Fault-Tolerant Neutral-Point-Clamped Converters [J].
Ceballos, Salvador ;
Pou, Josep ;
Robles, Eider ;
Zaragoza, Jordi ;
Luis Martin, Jose .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) :2709-2718
[2]   Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2660-2673
[3]   New Modulation Strategy to Balance the Neutral-Point Voltage for Three-Level Neutral-Clamped Inverter Systems [J].
Choi, Ui-Min ;
Lee, June-Seok ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (01) :91-100
[4]   Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System [J].
Choi, Ui-Min ;
Jeong, Hae-Gwang ;
Lee, Kyo-Beum ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) :2726-2739
[5]   Thermal Loading and Reliability of 10-MW Multilevel Wind Power Converter at Different Wind Roughness Classes [J].
Isidori, Andrea ;
Rossi, Fabio Mario ;
Blaabjerg, Frede ;
Ma, Ke .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (01) :484-494
[6]   Performance Improvement of LCL-Filter-Based Grid-Connected Inverters Using PQR Power Transformation [J].
Jeong, Hea-Gwang ;
Lee, Kyo-Beum ;
Choi, Sewan ;
Choi, Woojin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (05) :1320-1330
[7]   Space Vector Modulation for Three-Level NPC Converter With Neutral Point Voltage Balance and Switching Loss Reduction [J].
Jiao, Yang ;
Lee, Fred C. ;
Lu, Sizhao .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) :5579-5591
[8]  
Ku HK, 2012, IEEE ENER CONV, P4519, DOI 10.1109/ECCE.2012.6342206
[9]   Comparison of Tolerance Controls for Open-Switch Fault in a Grid-Connected T-Type Rectifier [J].
Lee, June-Seok ;
Choi, Ui-Min ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (10) :5810-5820
[10]   Open-Switch Fault Tolerance Control for a Three-Level NPC/T-Type Rectifier in Wind Turbine Systems [J].
Lee, June-Seok ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (02) :1012-1021