Ultrasound-based logistic regression model LR2 versus magnetic resonance imaging for discriminating between benign and malignant adnexal masses: a prospective study

被引:16
|
作者
Shimada, Kanane [1 ,4 ]
Matsumoto, Koji [1 ]
Mimura, Takashi [1 ]
Ishikawa, Tetsuya [1 ]
Munechika, Jiro [2 ]
Ohgiya, Yoshimitsu [2 ]
Kushima, Miki [3 ]
Hirose, Yusuke [1 ]
Asami, Yuka [1 ]
Iitsuka, Chiaki [1 ]
Miyamoto, Shingo [1 ]
Onuki, Mamiko [1 ]
Tsunoda, Hajime [4 ]
Matsuoka, Ryu [1 ]
Ichizuka, Kiyotake [1 ]
Sekizawa, Akihiko [1 ]
机构
[1] Showa Univ, Sch Med, Dept Obstet & Gynecol, Shinagawa Ku, 1-5-8 Hatanodai, Tokyo 1428666, Japan
[2] Showa Univ, Sch Med, Dept Radiol, Shinagawa Ku, 1-5-8 Hatanodai, Tokyo 1428666, Japan
[3] Showa Univ, Sch Med, Koto Toyosu Hosp, Dept Pathol,Koto Ku, 5-1-38 Toyosu, Tokyo 1358577, Japan
[4] NTT Med Ctr Tokyo, Dept Obstet & Gynecol, Shinagawa Ku, 5-9-22 Higashi Gotanda, Tokyo 1418625, Japan
关键词
IOTA; Ultrasound; Magnetic resonance imaging (MRI); Ovarian tumor; SUBJECTIVE ASSESSMENT; INTEROBSERVER AGREEMENT; MUCINOUS CYSTADENOMA; BORDERLINE; DIAGNOSIS; RISK; MR;
D O I
10.1007/s10147-017-1222-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The diagnostic performances of the International Ovarian Tumor Analysis (IOTA) ultrasound-based logistic regression model (LR2) and magnetic resonance imaging (MRI) in discriminating between benign and malignant adnexal masses have not been directly compared in a single study. Using the IOTA LR2 model and subjective interpretation of MRI findings by experienced radiologists, 265 consecutive patients with adnexal masses were preoperatively evaluated in two hospitals between February 2014 and December 2015. Definitive histological diagnosis of excised tissues was used as a gold standard. From the 265 study subjects, 54 (20.4%) tumors were histologically diagnosed as malignant (including 11 borderline and 3 metastatic tumors). Preoperative diagnoses of malignant tumors showed 91.7% total agreement between IOTA LR2 and MRI, with a kappa value of 0.77 [95% confidence interval (CI), 0.68-0.86]. Sensitivity of IOTA LR2 (0.94, 95% CI, 0.85-0.98) for predicting malignant tumors was similar to that of MRI (0.96, 95% CI, 0.87-0.99; P = 0.99), whereas specificity of IOTA LR2 (0.98, 95% CI, 0.95-0.99) was significantly higher than that of MRI (0.91, 95% CI, 0.87-0.95; P = 0.002). Combined IOTA LR2 and MRI results gave the greatest sensitivity (1.00, 95% CI, 0.93-1.00) and had similar specificity (0.91, 95% CI, 0.86-0.94) to MRI. The IOTA LR2 model had a similar sensitivity to MRI for discriminating between benign and malignant tumors and a higher specificity compared with MRI. Our findings suggest that the IOTA LR2 model, either alone or in conjunction with MRI, should be included in preoperative evaluation of adnexal masses.
引用
收藏
页码:514 / 521
页数:8
相关论文
共 10 条
  • [1] Ultrasound-based logistic regression model LR2 versus magnetic resonance imaging for discriminating between benign and malignant adnexal masses: a prospective study
    Kanane Shimada
    Koji Matsumoto
    Takashi Mimura
    Tetsuya Ishikawa
    Jiro Munechika
    Yoshimitsu Ohgiya
    Miki Kushima
    Yusuke Hirose
    Yuka Asami
    Chiaki Iitsuka
    Shingo Miyamoto
    Mamiko Onuki
    Hajime Tsunoda
    Ryu Matsuoka
    Kiyotake Ichizuka
    Akihiko Sekizawa
    International Journal of Clinical Oncology, 2018, 23 : 514 - 521
  • [2] Comparison of IOTA three-step strategy and logistic regression model LR2 for discriminating between benign and malignant adnexal masses
    Jose Hidalgo, Juan
    Llueca, Antoni
    Zolfaroli, Irene
    Veiga, Nadia
    Ortiz, Ester
    Luis Alcazar, Juan
    MEDICAL ULTRASONOGRAPHY, 2021, 23 (02) : 168 - 175
  • [3] Comparison of ultrasound-based ADNEX model with magnetic resonance imaging for discriminating adnexal masses: a multi-center study
    Hu, Yanli
    Chen, Bo
    Dong, Hongmei
    Sheng, Bo
    Xiao, Zhibo
    Li, Jia
    Tian, Wei
    Lv, Furong
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [4] Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
    Tian, Cai
    Wen, Shu-Bin
    Zhao, Cong-Ying
    Yan, Xiao-Nan
    Du, Jie-Xian
    BMC WOMENS HEALTH, 2023, 23 (01)
  • [5] Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
    Cai Tian
    Shu-Bin Wen
    Cong-Ying Zhao
    Xiao-Nan Yan
    Jie-Xian Du
    BMC Women's Health, 23
  • [6] Diagnostic value of magnetic resonance imaging for malignant ovarian tumors mis-subclassified by the ultrasound-based ADNEX model
    Jiang, Meijiao
    Yuan, Congcong
    Lu, Siwei
    Zhu, Yunkai
    Chu, Caiting
    Li, Wenhua
    FRONTIERS IN ONCOLOGY, 2025, 15
  • [7] Ovarian cancer prediction in adnexal masses using ultrasound-based logistic regression models: a temporal and external validation study by the IOTA group
    Timmerman, D.
    Van Calster, B.
    Testa, A. C.
    Guerriero, S.
    Fischerova, D.
    Lissoni, A. A.
    Van Holsbeke, C.
    Fruscio, R.
    Czekierdowski, A.
    Jurkovic, D.
    Savelli, L.
    Vergote, I.
    Bourne, T.
    Van Huffel, S.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (02) : 226 - 234
  • [8] Ultrasound Radiomics-Based Logistic Regression Model to Differentiate Between Benign and Malignant Breast Nodules
    Shi, Shanshan
    An, Xin
    Li, Yuhong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (04) : 869 - 879
  • [9] Lesion size affects diagnostic performance of IOTA logistic regression models, IOTA simple rules and risk of malignancy index in discriminating between benign and malignant adnexal masses
    Di Legge, A.
    Testa, A. C.
    Ameye, L.
    Van Calster, B.
    Lissoni, A. A.
    Leone, F. P. G.
    Savelli, L.
    Franchi, D.
    Czekierdowski, A.
    Trio, D.
    Van Holsbeke, C.
    Ferrazzi, E.
    Scambia, G.
    Timmerman, D.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (03) : 345 - 354
  • [10] A comparison between an ultrasound based prediction model (LR2) and the Risk of Ovarian Malignancy Algorithm (ROMA) to assess the risk of malignancy in women with an adnexal mass
    Kaijser, Jeroen
    Van Gorp, Toon
    Van Hoorde, Kirsten
    Van Holsbeke, Caroline
    Sayasneh, Ahmad
    Vergote, Ignace
    Bourne, Tom
    Timmerman, Dirk
    Van Calster, Ben
    GYNECOLOGIC ONCOLOGY, 2013, 129 (02) : 377 - 383