Evaluation of endothelial/Descemet membrane complex of eye bank donor corneas using enhanced depth imaging optical coherence tomography

被引:2
|
作者
Syed, Zeba A. [1 ]
Gameiro, Gustavo Rosa [1 ]
Ruggeri, Marco [1 ]
Elsawy, Amr [1 ,2 ]
Sayed-Ahmed, Ibrahim [1 ]
Roongpoovapatr, Vatookarn [1 ]
Abdel-Mottaleb, Mohamed [2 ]
Abou Shousha, Mohamed [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, 900 NW 17th St, Miami, FL 33136 USA
[2] Univ Miami, Dept Elect & Comp Engn, Coll Engn, Coral Gables, FL 33124 USA
来源
CLINICAL OPHTHALMOLOGY | 2019年 / 13卷
关键词
corneal transplant; Fuchs' endothelial corneal dystrophy; corneal graft screening; microscope-integrated OCT; DIAGNOSIS;
D O I
10.2147/OPTH.S185455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo. Design: Prospective interventional study. Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs' endothelial corneal dystrophy were also evaluated for comparison. Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea. Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17 +/- 4 mu m. The difference between donor cornea En/DM thickness and that of control subjects (16 +/- 2 mu m) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs' endothelial corneal dystrophy eyes (25 +/- 5 mu m) and both donor corneas (p<0.0001) and control subjects (p<0.0001). Conclusions: We have described a new technique to measure En/DM complex thickness in eye bank donor corneas stored in a sealed sterile case. This may represent a novel adjunctive approach to screen corneal grafts for early endothelial disease.
引用
收藏
页码:789 / 794
页数:6
相关论文
共 4 条
  • [1] Effect of the use of intraoperative optical coherence tomography in descemet's membrane endothelial keratoplasty
    Cano-Ortiz, Antonio
    Sanchez-Ventosa, Alvaro
    Gonzalez, Marta Villalba
    Gonzalez-Cruces, Timoteo
    Perez, Maria Dolores Lopez
    Ramos, Jose Carlos Diaz
    Perez-Angulo, Javier Gersol
    Miranda, Elisa Palacin
    Pinero, David P.
    Villarrubia, Alberto
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [2] Three-Dimensional Assessment of Descemet Membrane Reflectivity by Optical Coherence Tomography in Fuchs Endothelial Corneal Dystrophy
    Suzuki, Takanori
    Yamaguchi, Takefumi
    Yagi-Yaguchi, Yukari
    Kasamatsu, Hirotsugu
    Tomida, Daisuke
    Fukui, Masaki
    Shimazaki, Jun
    CORNEA, 2024, 43 (02) : 207 - 213
  • [3] Depth-resolved imaging of colon tumor using optical coherence tomography and fluorescence laminar optical tomography
    Tang, Qinggong
    Wang, Jianting
    Frank, Aaron
    Lin, Jonathan
    Li, Zhifang
    Chen, Chao-Wei
    Jin, Lily
    Wu, Tongtong
    Greenwald, Bruce D.
    Mashimo, Hiroshi
    Chen, Yu
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 5218 - 5232
  • [4] Evaluation of Tear Meniscus Dynamics Using Anterior Segment Swept-Source Optical Coherence Tomography After Topical Solution Instillation for Dry Eye
    Akiyama-Fukuda, Reina
    Usui, Tomohiko
    Yoshida, Tatsuya
    Yamagami, Satoru
    CORNEA, 2016, 35 (05) : 654 - 658