Stitching 3D Ultrasound Head Images of Neonates to Monitor Changes in Ventricular Volume

被引:0
作者
Chamain, H. G. L. D. [1 ]
Fenster, Aaron [2 ]
Nanayakkara, Nuwan D. [1 ]
机构
[1] Univ Moratuwa, Dept Elect & Telecommun Engn, Moratuwa, Sri Lanka
[2] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
来源
2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES) | 2016年
关键词
parameter tuning; rigid registration; stitching; ultrasound; NONRIGID REGISTRATION; MUTUAL INFORMATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) images are taken in 3-dimensional (3D) space to monitor the changes in the ventricular volume of neonates. Due to the small field of view of US imaging, the head image is taken as two parts. To properly monitor and analyze the images, the two parts need to be stitched together in 3D space. In this paper, we propose a technique based on rigid registration for this purpose. User provided corresponding landmarks of the two images are used for coarse alignment. Then mutual information based rigid transformation is performed for fine alignment of moving image on to the fixed image. Finally, the fixed and moving images are stitched together to produce the final output. Furthermore, we have analyzed the optimal parameter settings for the registration procedure to minimize the registration error. We achieved a mean registration accuracy of 2.71mm for four data sets of neonatal 3D US head images using the proposed method.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 14 条
  • [1] Andronache A, 2005, LECT NOTES COMPUT SC, V3750, P976, DOI 10.1007/11566489_120
  • [2] Multi-modal non-rigid registration of medical images based on mutual information maximization
    Ardizzone, Edoardo
    Gambino, Orazio
    La Cascia, Marco
    Lo Presti, Liliana
    Pirrone, Roberto
    [J]. 14TH INTERNATIONAL CONFERENCE ON IMAGE ANALYSIS AND PROCESSING, PROCEEDINGS, 2007, : 743 - +
  • [3] Chan R., 2006, P SPIE
  • [4] Lange T., 2008, INT J COMPUT ASSIST, V4
  • [5] Nonrigid Image Registration Using Conditional Mutual Information
    Loeckx, Dirk
    Slagmolen, Pieter
    Maes, Frederik
    Vandermeulen, Dirk
    Suetens, Paul
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 19 - 29
  • [6] Maintz J.B., 1998, Medical image analysis, V2
  • [7] A "Twisting and Bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Samarabandu, Jagath
    Fenster, Aaron
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (10) : 1378 - 1388
  • [8] Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Samarabandu, Jagath
    Parraga, Grace
    Fenster, Aaron
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 373 - 385
  • [9] Pennec X., 2000, HDB MED IMAGING PROC, V31, P542
  • [10] USER-GUIDED SEGMENTATION OF PRETERM NEONATE VENTRICULAR SYSTEM FROM 3-D ULTRASOUND IMAGES USING CONVEX OPTIMIZATION
    Qiu, Wu
    Yuan, Jing
    Kishimoto, Jessica
    McLeod, Jonathan
    Chen, Yimin
    de Ribaupierre, Sandrine
    Fenster, Aaron
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (02) : 542 - 556