Spatial inhomogeneity of metals in particulate matter on ambient air filters determined by LA-ICP-MS and comparison with acid digestion ICP-MS

被引:16
作者
Brown, Richard J. C. [1 ]
Jarvis, Kym. E. [2 ]
Disch, Benoit A. [2 ]
Goddard, Sharon L. [1 ]
Brown, Andrew S. [1 ]
机构
[1] Natl Phys Lab, Analyt Sci Team, Teddington TW11 0LW, Middx, England
[2] Univ London Imperial Coll Sci Technol & Med, Ctr Environm Policy, Ascot SL5 7PY, Berks, England
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2009年 / 11卷 / 11期
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; AEROSOLS; CALIBRATION;
D O I
10.1039/b911441f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) has been used to examine the spatial distribution of metals in particulate matter on ambient air filters. The implications of the inhomogeneous distribution observed for the sub-sampling of such filters for multiple analyses have been discussed. It has been shown that large biases in measured values may occur unless the position and size of the sub-sample are chosen judiciously. Additionally, LA-ICP-MS has been compared against acid digestion ICP-MS as an alternative method for the determination of metals in particulate matter. It has been shown that the majority of variation in the LA-ICP-MS sensitivity accrues from small differences in the positioning of samples.
引用
收藏
页码:2022 / 2029
页数:8
相关论文
共 23 条
  • [1] [Anonymous], 2008, OFF J EUR UNION, V152, P1
  • [2] Twenty-five years of nationwide ambient metals measurement in the United Kingdom: concentration levels and trends
    Brown, Richard J. C.
    Yardley, Rachel E.
    Muhunthan, Dharsheni
    Butterfield, David M.
    Williams, Melanie
    Woods, Peter T.
    Brown, Andrew S.
    Goddard, Sharon L.
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 142 (1-3) : 127 - 140
  • [3] The Effect of Isotopic Composition on the Uncertainty of Routine Metal Mass Concentration Measurements in Ambient Air
    Brown, Richard J. C.
    Goddard, Sharon L.
    Brown, Andrew S.
    Yardley, Rachel E.
    [J]. JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2008,
  • [4] Sample matrix and critical interference effects on the recovery and accuracy of concentration measurements of arsenic in ambient particulate samples using ICP-MS
    Brown, RJC
    Yardley, RE
    Brown, AS
    Milton, MJT
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) : 703 - 705
  • [5] BROWN RJC, 2009, 34 NPL AS
  • [6] Atomic spectrometry update. Environmental analysis
    Butler, Owen T.
    Cook, Jennifer M.
    Davidson, Christine M.
    Harrington, Chris F.
    Miles, Douglas L.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (02) : 131 - 177
  • [7] BUTTERFIELD DM, 2008, 020 NPL AS RES
  • [8] Determination of soluble ions and elements in ambient air suspended particulate matter: Inter-technique comparison of XRF, IC and ICP for sample-by-sample quality control
    Canepari, S.
    Perrino, C.
    Astolfi, M. L.
    Catrambone, M.
    Perret, D.
    [J]. TALANTA, 2009, 77 (05) : 1821 - 1829
  • [9] An assessment of calibration strategies for the quantitative and semi-quantitative analysis of calcium carbonate matrices by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)
    Craig, CA
    Jarvis, KE
    Clarke, LJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) : 1001 - 1008
  • [10] Assessment of pressed calcium phosphate pellets for calibration of LA-ICP-MS
    Disch, B. A.
    Jarvis, K. E.
    Linge, K. L.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A142 - A142