The Relationship Between Hemihamate Graft Size and Proximal Interphalangeal Joint Flexion for Reconstruction of Fracture-Dislocations: A Biomechanical Study

被引:3
|
作者
Elliott, River M. [1 ]
Nayar, Suresh K. [1 ]
Giladi, Aviram M. [1 ]
Forthman, Christopher L. [1 ]
Parks, Brent G. [1 ]
Means, Kenneth R., Jr. [1 ]
机构
[1] MedStar Union Mem Hosp, Curtis Natl Hand Ctr, Baltimore, MD USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2019年 / 44卷 / 08期
关键词
Hemihamate; PIP fracture dislocation; HEMI-HAMATE AUTOGRAFT; VOLAR PLATE ARTHROPLASTY; REPLACEMENT ARTHROPLASTY; FIXATION;
D O I
10.1016/j.jhsa.2018.09.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to determine the relationship between hemihamate graft size and proximal interphalangeal (PIP) joint flexion in a biomechanical fracture-dislocation model. Methods We simulated middle finger PIP fracture-dislocations in 5 cadaver hands by resecting 50% of the palmar articular surface of the middle phalanx (P2) base. Fluoroscopy was used to confirm dorsal subluxation of the middle phalanx base after resection. A 10-mm osteochondral hamate graft was contoured to reconstruct the volar lip of the middle phalanx and was progressively downsized by 2-mm increments for each trial. A computer-controlled articulator and jig simulated active flexion and extension of the fingers. Maximum PIP flexion was measured at each graft size using fluoroscopy and digital imaging software. Clinically significant flexion block was defined as PIP flexion less than 90 degrees. Results The actual mean size of the volar defect created was 52% (3.5 mm) of the middle phalanx articular surface, which created instability and dorsal subluxation in all tested fingers. After hemihamate reconstruction, all specimens were stable throughout flexion and extension for all graft sizes. A flexion block of 90 degrees occurred at a mean graft size of 191% of the defect (6.5 mm). With regard to the volar lip of the P2, grafts that projected an average 0.8 mm past the native volar lip position had 98 degrees (range, 84 degrees-107 degrees) maximum PIP flexion. Grafts that projected an average of 3.1 mm past the native volar lip position had 90 degrees (range, 69 degrees-100 degrees) maximum PIP flexion. Linear regression modeling incorporating all of the results predicted flexion block to occur at a graft size as small as166% of the 50% volar P2 defect. In this model, for every 50% (1.7-mm) increase in graft size relative to the defect, PIP flexion decreased by approximately 6 degrees. Conclusions Nonanatomical hemihamate grafts produce a PIP flexion block at extreme sizes, predicted to occur at greater than 166% of a 50% P2 base articular defect in our model. This suggests that relatively large grafts can be used for reconstruction of PIP fracture-dislocations without substantial biomechanical block to PIP flexion. We suggest sizing no larger than 3 mm past the native P2 volar lip position to avoid an important mechanical block to PIP flexion. Clinical relevance The information from this study helps surgeons understand how large a hemihamate graft can be used for P2 volar base reconstruction before having a negative impact on PIP flexion. Copyright (C) 2019 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:696.e1 / 696.e6
页数:6
相关论文
共 11 条
  • [1] Modified Hemihamate Arthroplasty Technique for Treatment of Acute Proximal Interphalangeal Joint Fracture-Dislocations
    Yang, Dae Suk
    Lee, Sang Ki
    Kim, Kap Jung
    Choy, Won Sik
    ANNALS OF PLASTIC SURGERY, 2014, 72 (04) : 411 - 416
  • [2] Proximal interphalangeal joint dislocations and fracture-dislocations
    Kolovich, Gregory P.
    Heifner, John J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (2_SUPPL) : 27S - 34S
  • [3] Fracture-dislocations of the Proximal Interphalangeal Joint
    Elfar, John
    Mann, Tobias
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2013, 21 (02) : 88 - 98
  • [4] Variable Adjustment Methods for Hemihamate Autograft Arthroplasty in Proximal Interphalangeal Joint Fracture/Dislocations
    Heo, Jae-Woo
    Whang, Jong Ick
    Park, Hyun Sik
    ANNALS OF PLASTIC SURGERY, 2023, 91 (06) : 720 - 725
  • [5] Stability of Acute Dorsal Fracture Dislocations of the Proximal Interphalangeal Joint: A Biomechanical Study
    Tyser, Andrew R.
    Tsai, Michael A.
    Parks, Brent G.
    Means, Kenneth R., Jr.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (01): : 13 - 18
  • [6] Treatment for Acute Proximal Interphalangeal Joint Fractures and Fracture-Dislocations: A Systematic Review of the Literature
    Gianakos, Arianna
    Yingling, John
    Athens, Christian M.
    Barra, Andrew E.
    Capo, John T.
    JOURNAL OF HAND AND MICROSURGERY, 2020, 12 : S9 - S15
  • [7] Volar Buttress Plating for Unstable Dorsal Fracture-Dislocations of the Proximal Interphalangeal Joint
    Singh, Talvinder
    Jayawardhana, Roshenka
    Craigen, Michael
    Rajaratnam, Vaikunthan
    JOURNAL OF HAND AND MICROSURGERY, 2019, 11 (02) : 106 - 110
  • [8] A Percutaneous Technique to Treat Unstable Dorsal Fracture-Dislocations of the Proximal Interphalangeal Joint
    Vitale, Mark A.
    White, Neil J.
    Strauch, Robert J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (09): : 1453 - 1459
  • [9] Long-term outcomes after extension block pinning for fracture-dislocations of the proximal interphalangeal joint
    Nordback, Panu H.
    Westman, Marjut
    Waris, Eero
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (09) : 927 - 934
  • [10] Hemi-Hamate Arthroplasty Provides Functional Reconstruction of Acute and Chronic Proximal Interphalangeal Fracture-Dislocations
    Calfee, R. P.
    Kiefhaber, T. R.
    Sommerkamp, T. G.
    Stern, P. J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (07): : 1232 - 1241