Contrast agent recognition in small animal CT using the Medipix2 detector

被引:53
作者
Firsching, Markus [1 ]
Butler, Anthony P. [2 ,3 ]
Scott, Nicola [3 ]
Anderson, Nigel G. [3 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Phys, D-8520 Erlangen, Germany
[2] Univ Canterbury, Dept Elect & Comp Engn, Christchurch 1, New Zealand
[3] Univ Otago, Sch Med, Christchurch, New Zealand
关键词
X-ray imaging; Computed tomography; Bio-imaging; Medipix; Photon counting; Pixel detector; Material decomposition; Material reconstruction; K-edge; PIXEL DETECTORS;
D O I
10.1016/j.nima.2009.03.141
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Energy resolving capabilities of X-ray detectors like the Medipix2 and the upcoming Medipix3 offer access to spectral information which is a new domain of information in medical imaging. In conventional CT of a composite object only the cumulative contribution of all involved materials to the attenuation is measurable, but not how much each material component contributes to this attenuation is measured. Therefore, contrast agent cannot be distinguished from bone or calcifications. The method of material reconstruction exploits the energy information to determine the partial densities of the involved materials using a maximum likelihood approach, i.e. it allows the separation of contrast agent from tissue, bones and calcifications. We have employed the Medipix All Resolution System (MARS) scanner equipped with a Medipix2 MXR and performed a CT scan of a mouse with iodine contrast agent in stomach and bowel. The method allows to separate the iodine contrast agent from all the other absorbing structures. In the iodine image, only the iodine concentration is visible, while the non-iodine (water) image shows all the other tissue structures and bones. The method of material reconstruction was applied to real CT data of a biological sample for the first time. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 5 条
[1]  
[Anonymous], IEEE NUCL SCI S MED
[2]   Bio-medical X-ray imaging with spectroscopic pixel detectors [J].
Butler, A. P. H. ;
Anderson, N. G. ;
Tipples, R. ;
Cook, N. ;
Watts, R. ;
Meyer, J. ;
Bell, A. J. ;
Melzer, T. R. ;
Butler, P. H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) :141-146
[3]   Material resolving X-ray imaging using spectrum reconstruction with Medipix2 [J].
Firsching, Markus ;
Talla, Patrick Takoukam ;
Michel, Thilo ;
Anton, Gisela .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) :19-23
[4]   Investigation of charge carrier transport and charge sharing in X-ray semiconductor pixel detectors such as Medipix2 [J].
Korn, Alexander ;
Firsching, Markus ;
Anton, Gisela ;
Hoheisel, Martin ;
Michel, Thilo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) :239-242
[5]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283