Partial volume-aware assessment of multiple sclerosis lesions

被引:14
作者
Fartaria, Mario Joao [1 ,2 ,3 ,4 ]
Todea, Alexandra [5 ]
Kober, Tobias [1 ,2 ,3 ,4 ]
O'brien, Kieran [6 ,7 ]
Krueger, Gunnar [8 ]
Meuli, Reto [2 ,3 ]
Granziera, Cristina [9 ,10 ,11 ,12 ,13 ]
Roche, Alexis [1 ,2 ,3 ,4 ]
Cuadra, Meritxell Bach [2 ,3 ,4 ,14 ]
机构
[1] Siemens Healthcare AG, Adv Clin Imaging Technol HC CMEA SUI DI PI, Lausanne, Switzerland
[2] Lausanne Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[3] Univ Lausanne UNIL, Lausanne, Switzerland
[4] Ecole Polytech Fed Lausanne, Signal Proc Lab LTS 5, Lausanne, Switzerland
[5] Pourtales Hosp, Dept Radiol, Neuchatel, Switzerland
[6] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld, Australia
[7] Siemens Healthcare Pty Ltd, Brisbane, Qld, Australia
[8] Siemens Healthcare Ltd, Zurich, Switzerland
[9] Univ Hosp Basel, Neurol Clin & Policlin, Dept Med, Basel, Switzerland
[10] Univ Hosp Basel, Neurol Clin & Policlin, Dept Clin Res, Basel, Switzerland
[11] Univ Hosp Basel, Neurol Clin & Policlin, Dept Biomed Engn, Basel, Switzerland
[12] Univ Basel, Basel, Switzerland
[13] Univ Hosp Basel, Dept Med & Biomed Engn, Translat Imaging Neurol ThINK Basel, Basel, Switzerland
[14] CIBM, MIAL, Lausanne, Switzerland
关键词
Partial volume; Multiple sclerosis; MRI; Lesion segmentation; WHITE-MATTER LESIONS; AUTOMATIC SEGMENTATION; TISSUE CLASSIFICATION; MRI; CRITERIA; IMAGES;
D O I
10.1016/j.nicl.2018.01.011
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
White-matter lesion count and volume estimation are key to the diagnosis and monitoring of multiple sclerosis (MS). Automated MS lesion segmentation methods that have been proposed in the past 20 years reach their limits when applied to patients in early disease stages characterized by low lesion load and small lesions. We propose an algorithm to automatically assess MS lesion load (number and volume) while taking into account the mixing of healthy and lesional tissue in the image voxels due to partial volume effects. The proposed method works on 3D MPRAGE and 3D FLAIR images as obtained from current routine MS clinical protocols. The method was evaluated and compared with manual segmentation on a cohort of 39 early-stage MS patients with low disability, and showed higher Dice similarity coefficients (median DSC=0.55) and higher detection rate (median DR=61%) than two widely used methods (median DSC=0.50, median DR < 45%) for automated MS lesion segmentation. We argue that this is due to the higher performance in segmentation of small lesions, which are inherently prone to partial volume effects.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 49 条
  • [21] elastix: A Toolbox for Intensity-Based Medical Image Registration
    Klein, Stefan
    Staring, Marius
    Murphy, Keelin
    Viergever, Max A.
    Pluim, Josien P. W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 196 - 205
  • [22] MP2RAGE Multiple Sclerosis Magnetic Resonance Imaging at 3 T
    Kober, Tobias
    Granziera, Cristina
    Ribes, Delphine
    Browaeys, Patrick
    Schluep, Myriam
    Meuli, Reto
    Frackowiak, Richard
    Gruetter, Rolf
    Krueger, Gunnar
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (06) : 346 - 352
  • [23] SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging
    Larsson, EG
    Erdogmus, D
    Yan, R
    Principe, JC
    Fitzsimmons, JR
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2003, 163 (01) : 121 - 123
  • [24] Automated detection of multiple sclerosis lesions in serial brain MRI
    Llado, Xavier
    Ganiler, Onur
    Oliver, Arnau
    Marti, Robert
    Freixenet, Jordi
    Valls, Laia
    Vilanova, Joan C.
    Ramio-Torrenta, Lluis
    Rovira, Alex
    [J]. NEURORADIOLOGY, 2012, 54 (08) : 787 - 807
  • [25] Segmentation of multiple sclerosis lesions in brain MRI: A review of automated approaches
    Llado, Xavier
    Oliver, Arnau
    Cabezas, Mariano
    Freixenet, Jordi
    Vilanova, Joan C.
    Quiles, Ana
    Valls, Laia
    Ramio-Torrenta, Lluis
    Rovira, Alex
    [J]. INFORMATION SCIENCES, 2012, 186 (01) : 164 - 185
  • [26] Morra J., 2008, Multiple Sclerosis Lesion Segmentation Challenge, P1
  • [27] Nocedal J, 2006, SPRINGER SER OPER RE, P1, DOI 10.1007/978-0-387-40065-5
  • [28] Medical progress: Multiple sclerosis.
    Noseworthy, JH
    Lucchinetti, C
    Rodriguez, M
    Weinshenker, BG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (13) : 938 - 952
  • [29] New variants of a method of MRI scale standardization
    Nyúl, LG
    Udupa, JK
    Zhang, X
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) : 143 - 150
  • [30] Pham Dzung L., 2000, MATH METH BIOM IM AN