Voltammetric behavior and trace determination of Pb2+ at a mercury-free screen-printed silver electrode

被引:49
作者
Zen, JM [1 ]
Yang, CC [1 ]
Kumar, AS [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
lead; screen-printed electrode; silver; underpotential deposition;
D O I
10.1016/S0003-2670(02)00472-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Screen-printed silver electrodes (AgSPEs), without chemical modification, has been investigated as disposable sensors for the measurement of trace levels of Pb2+. potential segment analysis indicates that the formation of underpotential and bulk depositions of Pb is not strongly coupled on the AgSPE. The possibility of determining Pb2+ at trace levels using the reversible underpotential deposition peak was examined by square-wave anodic stripping voltammetry without removal of oxygen. Under the optimized analytical conditions, the obtained sensitivity, linearity, and detection limit are 0.355 muA/ppb, 5-80 ppb (r = 0.9992), and 0.46 ppb (S/N = 3), respectively. The electrode is quite stable for repetitive measurements. The interference effect was thoroughly studied with various metals and no significant change in current was found in the determination of 5 ppb Pb2+. The practical applications were demonstrated to measure trace Pb2+ in natural waters. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 25 条
  • [11] MARKHOUFI L, 2000, ELECTROCHEM COMMUN, V2, P552
  • [12] ANODIC-STRIPPING VOLTAMMETRY OF LEAD WITH MICROLITER VOLUMES OF ELECTROLYTES AND SILVER-PLATED GLASSY-CARBON ELECTRODES
    MIWA, T
    NISHIMURA, Y
    MIZUIKE, A
    [J]. ANALYTICA CHIMICA ACTA, 1982, 140 (01) : 59 - 64
  • [13] UNDERPOTENTIAL DEPOSITION AND ELECTROCRYSTALLIZATION OF METALS - AN ATOMIC VIEW BY SCANNING TUNNELING MICROSCOPY
    OBRETENOV, W
    SCHMIDT, U
    LORENZ, WJ
    STAIKOV, G
    BUDEVSKI, E
    CARNAL, D
    MULLER, U
    SIEGENTHALER, H
    SCHMIDT, E
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (03) : 692 - 703
  • [14] MODELING TRANSFORMATION PROCESSES IN UNDERPOTENTIAL LEAD ADSORBATE ON AG(111)
    POPOV, A
    DIMITROV, N
    VITANOV, T
    KASHCHIEV, D
    BUDEVSKI, E
    [J]. ELECTROCHIMICA ACTA, 1995, 40 (10) : 1495 - 1499
  • [15] An embedded atom approach to underpotential deposition phenomena
    Sánchez, CG
    Del Pópolo, MG
    Leiva, EPM
    [J]. SURFACE SCIENCE, 1999, 421 (1-2) : 59 - 72
  • [16] APPLICATION OF STRIPPING ANALYSIS TO DETERMINATION OF IODIDE WITH SILVER MICROELECTRODES
    SHAIN, I
    PERONE, SP
    [J]. ANALYTICAL CHEMISTRY, 1961, 33 (03) : 325 - &
  • [17] Stripping voltammetry of copper and lead using gold electrodes modified with self-assembled monolayers
    Shen, H
    Mark, JE
    Seliskar, CJ
    Mark, HB
    Heineman, WR
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 1997, 1 (03) : 241 - 247
  • [18] Electrochemical study of the interaction between fatty acid and oxidized copper
    Su, YY
    [J]. TRIBOLOGY INTERNATIONAL, 1997, 30 (06) : 423 - 428
  • [19] FILM-FORMING INHIBITION FOR THE ANODIC-DISSOLUTION OF TIN IN A HYDROCARBON ELECTROLYTE BY SOME METALLIC CATIONS
    WAHDAN, MH
    GOMMA, GK
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 1995, 41 (02) : 92 - 97
  • [20] Flow injection analysis of hydrogen peroxide on copper-plated screen-printed carbon electrodes
    Zen, JM