Self-Assembling, Low-Cost, and Modular mm-Scale Force Sensor

被引:19
作者
Gafford, Joshua B. [1 ]
Wood, Robert J. [1 ,2 ]
Walsh, Conor J. [1 ,2 ]
机构
[1] Harvard Univ, John A Paulson Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[2] Wyss Inst Biol Inspired Engn, Boston, MA 02115 USA
关键词
Force sensor; surgical robotics; haptics; light intensity modulation; SURGERY; TOOL;
D O I
10.1109/JSEN.2015.2476368
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The innovation in surgical robotics has seen a shift toward flexible systems that can access remote locations inside the body. However, a general reliance on the conventional fabrication techniques ultimately limits the complexity and the sophistication of the distal implementations of such systems, and poses a barrier to further innovation and widespread adoption. In this paper, we present a novel, self-assembling force sensor manufactured using a composite lamination fabrication process, wherein linkages pre-machined in the laminate provide the required degrees-of-freedom and fold patterns to facilitate self-assembly. Using the purely 2-D fabrication techniques, the energy contained within a planar elastic biasing element directly integrated into the laminate is released post-fabrication, allowing the sensor to self-assemble into its final 3-D shape. The sensors are batch-fabricated, further driving down the production costs. The transduction mechanism relies on the principle of light intensity modulation, which allows the sensor to detect axial forces with millinewton-level resolution. The geometry of the sensor was selected based on the size constraints inherent in minimally invasive surgery, as well as with a specific focus on optimizing the sensor's linearity. The sensor is unique from the fiber-based force sensors in that the emitter and the detector are encapsulated within the sensor itself. The bare sensor operates over a force range of 0-200 mN, with a sensitivity of 5 V/N and a resolution of 0.8 mN. The experimental results show that the sensor's stiffness can be tuned using a thicker material for the spring layer and/or encapsulation/integration with soft materials. The empirical validation shows that the sensor has the sensitivity and the resolution necessary to discern the biologically relevant forces in a simulated cannulation task.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 18 条
[1]   Complications of ERCP [J].
Anderson, Michelle A. ;
Fisher, Laurel ;
Jain, Rajeev ;
Evans, John A. ;
Appalaneni, Vasundhara ;
Ben-Menachem, Tamir ;
Cash, Brooks D. ;
Decker, G. Anton ;
Early, Dayna S. ;
Fanelli, Robert D. ;
Fisher, Deborah A. ;
Fukami, Norio ;
Hwang, Joo Ha ;
Ikenberry, Steven O. ;
Jue, Terry L. ;
Khan, Khalid M. ;
Krinsky, Mary Lee ;
Malpas, Phyllis M. ;
Maple, John T. ;
Sharaf, Ravi N. ;
Shergill, Amandeep K. ;
Dominitz, Jason A. .
GASTROINTESTINAL ENDOSCOPY, 2012, 75 (03) :467-473
[2]   Flexible Robotics [J].
Aron, Monish ;
Desai, Mihir M. .
UROLOGIC CLINICS OF NORTH AMERICA, 2009, 36 (02) :157-+
[3]  
Bajo A, 2013, IEEE INT CONF ROBOT, P232, DOI 10.1109/ICRA.2013.6630581
[4]   Design and Control of Concentric-Tube Robots [J].
Dupont, Pierre E. ;
Lock, Jesse ;
Itkowitz, Brandon ;
Butler, Evan .
IEEE TRANSACTIONS ON ROBOTICS, 2010, 26 (02) :209-225
[5]  
Gafford J. B., 2013, P ASME IDETC ROB MEC
[6]  
Gafford JB, 2014, IEEE INT CONF ROBOT, P1419, DOI 10.1109/ICRA.2014.6907038
[7]   A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery [J].
Iordachita, Iulian ;
Sun, Zhenglong ;
Balicki, Marcin ;
Kang, Jin U. ;
Phee, Soo Jay ;
Handa, James ;
Gehlbach, Peter ;
Taylor, Russell .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (04) :383-390
[8]  
Moreno I., 2008, P SPIE 8 INT C SOL S, V7058
[9]   MRI-Compatible Fiber-Optic Force Sensors for Catheterization Procedures [J].
Polygerinos, Panagiotis ;
Zbyszewski, Dinusha ;
Schaeffter, Tobias ;
Razavi, Reza ;
Seneviratne, Lakmal D. ;
Althoefer, Kaspar .
IEEE SENSORS JOURNAL, 2010, 10 (10) :1598-1608
[10]   Miniature 3-Axis Distal Force Sensor for Minimally Invasive Surgical Palpation [J].
Puangmali, Pinyo ;
Liu, Hongbin ;
Seneviratne, Lakmal D. ;
Dasgupta, Prokar ;
Althoefer, Kaspar .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2012, 17 (04) :646-656