Outcome of the pivotal study of the Aptus endovascular abdominal aortic aneurysms repair system

被引:30
|
作者
Mehta, Manish [1 ]
Henretta, John [2 ]
Glickman, Marc [3 ]
Deaton, David [4 ]
Naslund, Thomas C. [5 ]
Gray, Bruce [6 ]
McCann, Richard [7 ]
Jordan, William [8 ]
Fairman, Ronald [9 ]
机构
[1] Albany Med Coll, Dept Vasc & Endovasc Surg, Albany, NY 12208 USA
[2] Mission Hlth, Dept Vasc Surg, Asheville, NC USA
[3] Sentara Heart Hosp, Dept Vasc Surg, Norfolk, VA USA
[4] Georgetown Univ, Dept Vasc Surg, Washington, DC USA
[5] Vanderbilt Univ, Dept Vasc Surg, Nashville, TN 37235 USA
[6] Greenville Hosp Syst, Dept Vasc Surg, Greenville, SC USA
[7] Duke Univ, Dept Vasc Surg, Durham, NC 27706 USA
[8] Univ Alabama Birmingham, Dept Vasc Surg, Birmingham, AL 35487 USA
[9] Univ Penn, Dept Vasc Surg & Endovasc Therapy, Philadelphia, PA USA
关键词
MULTICENTER TRIAL; LIFELINE REGISTRY; CLINICAL-TRIAL; STENT GRAFT; COMPLICATIONS; NECKS;
D O I
10.1016/j.jvs.2014.02.017
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Endovascular treatment of abdominal aortic aneurysm (AAA) is associated with benefits over open surgery, yet limitations remain with current endovascular devices. This study was performed to assess outcomes of AAA repair with the Aptus endograft and EndoAnchors (Aptus Endosystems, Sunnyvale, Calif). Methods: This prospective, multicenter, single-arm investigational device exemption trial was conducted at 25 sites in the United States. A total of 155 patients were enrolled in the trial (mean age, 73 +/- 8 years; male, 93.5%; mean AAA diameter, 53.6 +/- 7.9 mm). The Aptus endograft is a two-component system: a multilumen, modular endograft with two docking limbs (Aptus Endograft System) and the Heli-FX Aortic Securement System comprising an electronically controlled applier (Heli-FX Applier) with helical EndoAnchors provided in a cassette and a deflectable sheath (Heli-FX Guide) designed for delivery of the applier to the target location for EndoAnchor implantation. The main eligibility criteria included proximal neck length of >= 12 mm, diameter of 19 to 29 mm, and infrarenal angulation of <= 60 degrees. The primary safety end point was freedom from major adverse events at 30 days, and the primary effectiveness end point was successful aneurysm treatment at 12 months. Thrombus-related events (TRE) were defined as limb occlusion or thromboembolism from the endograft. Subjects were observed for a median of 4.2 years, with imaging end points analyzed by a core laboratory and adverse events adjudicated by a clinical events committee. Results: Among 155 enrolled subjects, 153 (98.7%) underwent successful implantation of the Aptus endograft and a median of five EndoAnchors; two subjects were converted to open surgical repair during the initial procedure. Overall, the primary safety and effectiveness end points were met in 98.1% and 97.4% of the subjects, respectively. Aneurysm-related mortality was 0.6%, with one postdischarge cardiac death 18 days after implantation. There were noAAAruptures. There were no fractures of stents or EndoAnchors. There was one type I endoleak and one type III endoleak. Stent graft migration was noted in five subjects, none associated with sac enlargement, type I endoleak, or EndoAnchor dislocation from the endograft. AAA sac shrinkage of >= 5 mm at 1, 2, and 3 years was observed in 60.3%, 72.9%, and 81.7%, respectively. Sixty-one subjects (39.4%) experienced 113 TRE, associated with 80 reinterventions (in 58 subjects) unassociated with limb loss or death. A root cause analysis of TRE identified small, out-of-specification docking limbs with graft infolding and high local shear, resulting in thrombus formation within the endograft with subsequent distal embolization in some cases. Conclusions: Early results of the Aptus endograft trial met its safety and effectiveness end points; however, a high rate of TRE was observed because of manufacturing discrepancies. The findings confirm a low rate of type I and type III endoleaks, migration, and non-TRE reintervention with a high rate of aneurysm sac regression during midterm follow-up.
引用
收藏
页码:275 / 285
页数:11
相关论文
共 50 条
  • [21] Endovascular treatment of abdominal aortic aneurysms
    Treiman, GS
    Bernhard, VM
    ANNUAL REVIEW OF MEDICINE, 1998, 49 : 363 - 373
  • [22] Endovascular treatment of abdominal aortic aneurysms
    Faries, PL
    Morrissey, NJ
    Teodorescu, VJ
    Hollier, LH
    Marin, ML
    MOUNT SINAI JOURNAL OF MEDICINE, 2003, 70 (06): : 420 - 426
  • [23] Endovascular repair of abdominal aortic aneurysms with concomitant common iliac artery aneurysm: Outcome analysis of the EUROSTAR experience
    Hobo, Roel
    Sybrandy, Johannes E. M.
    Harris, Peter L.
    Buth, Jacob
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (01) : 12 - 22
  • [24] Long-term Outcomes Following Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms
    Gueroult, Aurelien M.
    Khan, Farhaan A.
    Stather, Philip W.
    Harrison, Seamus C.
    Boyle, Jonathan R.
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (03) : 428 - 435
  • [25] Preoperative Intrasac Thrombus Load Predicts Worse Outcome after Elective Endovascular Repair of Abdominal Aortic Aneurysms
    Sirignano, Pasqualino
    Menna, Danilo
    Capoccia, Laura
    Montelione, Nunzio
    Mansour, Wassim
    Rizzo, Anna Rita
    Sbarigia, Enrico
    Speziale, Francesco
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (10) : 1431 - 1436
  • [26] Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms
    de Niet, Arne
    Donselaar, Esme J.
    Holewijn, Suzanne
    Tielliu, Ignace F. J.
    Lardenoije, Jan Willem H. P.
    Zeebregts, Clark J.
    Reijnen, Michel M. P. J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (05) : 848 - 856
  • [27] Open and endovascular repair of abdominal aortic aneurysms - clinical picture, evidence, results
    Haertl, F.
    Reeps, C.
    Wilhelm, M.
    Ockert, S.
    Zimmermann, A.
    Eckstein, H. -H.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (24) : 1303 - 1308
  • [28] Primary Endo Anchoring in the Endovascular Repair of Abdominal Aortic Aneurysms With an Unfavorable Neck
    Perdikides, Theodosios
    Melas, Nikolaos
    Lagios, Konstantinos
    Saratzis, Athanasios
    Siafakas, Athanasios
    Bountouris, Ioannis
    Kouris, Nikolaos
    Avci, Murat
    Van den Heuvel, Danyel A. F.
    de Vries, Jean-Paul P. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (06) : 707 - 715
  • [29] Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms
    Schanzer, Andres
    Simons, Jessica P.
    Flahive, Julie
    Durgin, Jonathan
    Aiello, Francesco A.
    Doucet, Danielle
    Steppacher, Robert
    Messina, Louis M.
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (03) : 687 - 694
  • [30] Endovascular Aneurysm Repair Increases Aortic Arterial Stiffness When Compared to Open Repair of Abdominal Aortic Aneurysms
    Gray, Cleona
    Goodman, Patrick
    Badger, Stephen A.
    O'Malley, M. Kevin
    O'Donohoe, Martin K.
    McDonnell, Ciaran O.