Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis

被引:15
|
作者
Ahamed, Shadir Bughari Basheer [1 ]
Vanajassun, Purushothaman Pranav [1 ]
Rajkumar, Kothandaraman [1 ]
Mahalaxmi, Sekar [1 ]
机构
[1] SRM Dent Coll, Dept Conservat Dent & Endodont, Madras 600089, Tamil Nadu, India
关键词
Bending stress; cross-sectional design; finite element analysis; nickel-titanium rotary; BENDING PROPERTIES; INSTRUMENTS; MODELS; RESISTANCE; FRACTURE;
D O I
10.1016/j.joen.2017.12.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. Methods: A 3-dimensional model of the simulated root canal with 45 curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 A). Results: The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. Conclusions: The CTU designed instruments showed the least bending stress on a 45 degrees angulated simulated root canal when compared with all the other tested designs.
引用
收藏
页码:654 / 658
页数:5
相关论文
共 50 条
  • [21] A Comparative Computational Analysis of the Mechanical Behavior of Two Nickel-Titanium Rotary Endodontic Instruments
    Necchi, Silvia
    Petrini, Lorenza
    Taschieri, Silvio
    Migliavacca, Francesco
    JOURNAL OF ENDODONTICS, 2010, 36 (08) : 1380 - 1384
  • [22] Comparative analysis of mechanical properties of differently tapered nickel-titanium endodontic rotary instruments
    Fukumori, Yohei
    Nishijyo, Miki
    Tokita, Daisuke
    Miyara, Kana
    Ebihara, Arata
    Okiji, Takashi
    DENTAL MATERIALS JOURNAL, 2018, 37 (04) : 667 - 674
  • [23] Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis
    Kim, Hyeon-Cheol
    Shun-Pan, Gary
    Lee, Chan-Joo
    Kim, Byung-Min
    Park, Jeong-Kil
    Kang, Soon-Il
    JOURNAL OF ENDODONTICS, 2008, 34 (06) : 743 - 747
  • [24] Effect of root canal treatment procedures with a novel rotary nickel titanium instrument (TRUShape) on stress in mandibular molars: a comparative finite element analysis
    Noemi Bonessio
    Ana Arias
    Guiseppe Lomiento
    Ove A. Peters
    Odontology, 2017, 105 : 54 - 61
  • [25] Comparative Analysis of Three Nickel-Titanium Rotary Files in Severely Curved L-Shaped Root Canals: Preparation Time, Aberrations, and Fracture Rates
    Almnea, Raid Abdullah
    Albeaji, Sadun Mohammad Al Ageel
    Alelyani, Ahmed Ali
    AlHarith, Dalia
    Alshahrani, Abdulmajeed Saeed
    Al Malwi, Ahmed Abdullah
    Alobaid, Mohammed A.
    Al Moaleem, Mohammed M.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2024, 16 : 1 - 9
  • [26] Comparative evaluation of shaping ability of two nickel-titanium rotary systems using cone beam computed tomography
    Celikten, Berkan
    Uzuntas, Ceren Feriha
    Kursun, Sebnem
    Orhan, Ayse Isil
    Tufenkci, Pelin
    Orhan, Kaan
    Demiralp, Kemal Ozgur
    BMC ORAL HEALTH, 2015, 15
  • [27] Finite element analysis of bending and torsional loading of two different endodontic rotary files with different off-center geometric sections
    Eskibaglar, Mehmet
    Erdem, Serkan
    Kaman, Mete Onur
    Ocak, Mevlut Sinan
    MATERIALS TESTING, 2023, 65 (11) : 1707 - 1712
  • [28] Experimental and 2-Step Finite Element Analysis of Cyclic Fatigue Resistance of Conventional and Heat-Treated Rotary Endodontic Nickel-Titanium Instruments
    Chien, Philip Yuan-Ho
    Wan, Boyang
    Walsh, Laurence James
    Peters, Ove Andreas
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [29] Finite Element Analysis of Stress Distribution in Root Canals When Using a Variety of Post Systems Instrumented with Different Rotary Systems
    Yusufoglu, Selen Ince
    Saricam, Esma
    Ozdogan, Mahmut Sertac
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (07) : 1436 - 1448
  • [30] Micro-computed tomographic evaluation of the effect of the final apical size prepared by rotary nickel-titanium files on the removal efficacy of hard-tissue debris
    Xu, Ke
    Wang, Juan
    Wang, Ke
    Gen, Nan
    Li, Jin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2219 - 2229