Comparison of four methods for computing positive-sequence reactances of three-phase core-type transformers

被引:3
|
作者
Sorrentino, Elmer [1 ,2 ]
Alvarado, Sofia [1 ]
Silva, Pedro [1 ]
Carlos Burgos, Juan
机构
[1] Univ Simon Bolivar, Dept Convers & Transporte Energia, Caracas, Venezuela
[2] Univ Carlos III Madrid, Dept Ingn Elect, Madrid 28911, Spain
关键词
OPTIMIZATION; ASYMMETRY; DESIGN;
D O I
10.1049/iet-gtd.2013.0834
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study compares four methods for computing the positive-sequence reactances of three-phase core-type transformers: traditional basic formulae (TBF); two-dimensional (2D) finite difference method (FDM); and 2D and 3D finite element methods (FEM). A computer program was coded for the FDM, and a commercial software was applied for the FEM. The four applied methods are magnetostatic, and they were applied for computing the three positive-sequence short-circuit reactances of a three-winding transformer. The results of these methods were compared among themselves and with the measured values. In comparison with the measured values: (a) the TBF are relatively accurate, although they are based on an approximate representation of a simple 2D cross-section for the transformer window; (b) the results with different 2D cross-sections are also relatively accurate; (c) the results with the 3D modelling are more accurate than the TBF. These facts confirm that the space between the windings determines the value of the transformer positive-sequence reactance. Therefore the tank-winding distance and the tank magnetic permeability have little effect on the results. A weighted average of the results of different 2D cross-sections was computed with the FDM and with the FEM, and the obtained values are very close to the result with the 3D modelling. Although the results are relatively accurate, the main simplifications related to the performed magnetostatic analysis are highlighted.
引用
收藏
页码:1221 / 1227
页数:7
相关论文
共 34 条
  • [21] Application of 2D linear modeling for computing zero-sequence short-circuit impedances of 3-phase core-type YNynd transformers
    Sorrentino, Elmer
    Carlos Burgos, Juan
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 122 : 1 - 9
  • [22] Practical Experience in Using a Topological Model of a Core-Type Three-Phase Transformer-No-Load and Inrush Conditions
    Zirka, Sergey E.
    Moroz, Yuriy I.
    Hoidalen, Hans Kristian
    Lotfi, Abbas
    Chiesa, Nicola
    Arturi, Cesare M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 2081 - 2090
  • [23] A comparison between different methods of modeling hysteresis loop in three-phase three-legged transformers
    Mosayyebi, S. R.
    Jalilian, A.
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 287 - 291
  • [24] Influence of Magnetization Characteristics of Materials on the Iron Loss of Wound-Core-Type Three-Phase Transformers
    Shinya, Kunihiro
    Saito, Koichi
    ELECTRICAL ENGINEERING IN JAPAN, 2009, 169 (02) : 48 - 55
  • [25] Detection methods of unbalance factor and phase angle difference of positive and negative sequence componet of three-phase voltage
    Ma Wenchuan
    Zhang Shuo
    Shi Nan
    Wang Shuwen
    Baiyu
    Li Shumin
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [26] A Study on the Comparison of Two Harmonics Detection Methods of Three-phase Four-wire System
    Zhang, Yong
    Cheng, Xingong
    Zhang, Fengjun
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 8531 - 8535
  • [27] Currents and magnetic fluxes of the three-phase core-type delta-wye and wye-delta connected trasformer on no-load operation
    Simkevicius, Tedoras
    Lape, Romanas Jonas
    ECT 2007: ELECTRICAL AND CONTROL TECHNOLOGIES, PROCEEDINGS, 2007, : 194 - +
  • [28] Measurement of magnetic fields within a 3-phase core-type transformer during the positive-and zero-sequence impedance tests
    Sorrentino, Elmer
    De Gouveia, Arnaldo
    Carlos Burgos, Juan
    Hormazabal, Patricio
    Marquez, Johnny
    2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [29] Harmonies of the currents and magnetic fluxes of the three-phase core-type delta-wye and wye-delta connected transformer on no-load operation
    Simkevicius, Teodoras
    Lape, Romanas Jonas
    PROCEEDINGS OF THE XVII INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DISTURBANCES, EMD 2007, 2007, : 260 - 265
  • [30] A Modified Control Strategy for Three-Phase Four-Switch Active Power Filters Based on Fundamental Positive Sequence Extraction
    Xiao, Chun
    Ren, Yulu
    Cao, Qiong
    Wang, Lei
    Yin, Jingyu
    PROCESSES, 2024, 12 (11)