The vacuum expandable condom mold: A simple vaginal stent for McIndoe-style vaginoplasty

被引:18
作者
Adamson, CD [1 ]
Naik, BJ [1 ]
Lynch, DJ [1 ]
机构
[1] Texas A&M Univ, Hlth Sci Ctr, Scott & White Mem Hosp & Clin,Coll Med, Div Plast Surg,Scott Sherwood & Brindley Fdn, Temple, TX 76508 USA
关键词
D O I
10.1097/01.PRS.0000101536.28904.BB
中图分类号
R61 [外科手术学];
学科分类号
摘要
A new vaginal stent for application with the McIndoe vaginal reconstruction technique (using full-thickness skin grafts, as suggested by Burian) is presented. The advantages of this stent over previously described stents are as follows: the stent is soft and comfortable and does not have the attendant risk of pressure necrosis with potential bowel or bladder damage that has been noted with rigid stents; the materials are relatively inexpensive (under $30), presterilized, and can be easily constructed from existing materials widely available in most operating rooms; the size of the stent is easily customized to the patient's characteristics; the material does not fragment as some other materials previously described; and, most importantly, the volume reduction capability of the stent during skin graft application, stent insertion into the vaginal space, and stent removal has been found to be a great advantage with this stent technique. Finally, unlike other previously described stents, this one does not require the purchase of an expensive, ready-made device from a manufacturer (approximately $750 from Polytech Silimed, Dieburg, Germany). We have reconstructed a neovagina for three patients during the past 1.5 years using this technique. Graft uptake was almost 100 percent in all cases. Washing and drainage of the cutaneous cuff were not necessary for graft uptake or wound healing. There has been no evidence of contracture formation in any patient. We are happy to report that, at 1.5 years since having the procedure, the first patient is successfully able to have sexual intercourse.
引用
收藏
页码:664 / 666
页数:3
相关论文
共 13 条
[1]   McIndoe vaginoplasty with the inflatable vaginal stent [J].
Barutcu, A ;
Akguner, M .
ANNALS OF PLASTIC SURGERY, 1998, 41 (05) :568-569
[2]  
BURIAN F, 1935, ACTIVITE SCI MED PAR, V6, P3
[3]   REFINEMENT OF MCINDOE VAGINAL RECONSTRUCTION WITH ORFIT S-VAGINAL STENT [J].
CHEN, TH .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 94 (02) :394-396
[4]  
Chudacoff RM, 1996, OBSTET GYNECOL, V87, P865
[5]   AN INTRAOPERATIVE STENT FOR MCINDOE VAGINAL CONSTRUCTION [J].
CONCANNON, MJ ;
CROLL, GH ;
PUCKETT, CL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 91 (02) :367-368
[6]   The use of a tissue expander as a vaginal stent in vaginal reconstruction [J].
Hage, JJ .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (12) :1020-1020
[7]   Vaginal reconstruction [J].
Hensle, TW ;
Chang, DT .
UROLOGIC CLINICS OF NORTH AMERICA, 1999, 26 (01) :39-+
[8]  
KHANNA S, 1982, INT SURG, V67, P345
[9]   The expanded suprapubic area as a skin donor site in the treatment of congenital absence of the vagina [J].
Lerma, J ;
Palacín, JA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 105 (07) :2631-2632
[10]   VAGINAL STENTS FOR MCINDOES VAGINAL CONSTRUCTION [J].
MARINBERTOLIN, S ;
GONZALEZMARTINEZ, R ;
AMORRORTUVELAYOS, J .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 96 (07) :1751-1752