Chromatography-tandem mass spectrometry method for the simultaneous quantitation of metoprolol succinate and simvastatin in human plasma

被引:19
作者
Selvan, P. Senthamil [1 ]
Pal, T. K. [1 ]
机构
[1] Jadavpur Univ, Dept Pharmaceut Technol, Bioequivalence Study Ctr, Kolkata 700 032, India
关键词
Metoprolol succinate; Simvastatin; Propranolol hydrochloride; LC-MS/MS; Pharmacokinetics; LIQUID-CHROMATOGRAPHY; RELEASE METOPROLOL; DOSAGE FORM; PHARMACOKINETICS; BIOEQUIVALENCE; PROPRANOLOL; ATENOLOL;
D O I
10.1016/j.jpba.2008.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The liquid chromatographic-tandem mass spectrometry method was developed for the accurate quantitation of metoprolol succinate (MET) and simvastatin (SIM) in human plasma which were obtained from the pharmacokinetic (PK) study. The sample purification and pre-concentration was performed by protein precipitation technique using propranolol hydrochloride as working internal standard (WIS). The chromatographic separation was achieved using an isocratic mobile phase consisting of a mixture of acetonitrile and 0.5% formic acid (90: 10 (v/v), pH 3.5) flowing through C18 column at a flow rate of 0.2 ml/min. Electro spray ionization (ESI) with multiple reaction monitoring (MRM) was used to acquire mass spectra. Ions were monitored in positive mode and the mass transitions measured were m/z 268.1 -> m/z 103.2, m/z 441.3 -> m/z 325.1 and m/z 260.0 -> m/z 129.5 for MET, SIM and WIS, respectively. An extensive pre-study method validation was carried out in accordance with USFDA guidelines. The linearity for the calibration curve in the concentration range of 1.0-500.0 and 0.1-20 ng/ml for MET and SIM, respectively and the lower limits of quantitations (LLOQ) were 1.0 and 0.1 ng/ml for MET and SIM, respectively. The method was successfully applied to a PK study on fixed dose combination (FDC) tablet containing MET and SIM in healthy human subjects. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[2]  
Bakhtiar R, 2000, RAPID COMMUN MASS SP, V14, P1128, DOI 10.1002/1097-0231(20000715)14:13<1128::AID-RCM1>3.0.CO
[3]  
2-5
[4]   Validated HPLC-MS/MS method for simultaneous determination of simvastatin and simvastatin hydroxy acid in human plasma [J].
Barrett, B. ;
Huclova, J. ;
Borek-Dohalsky, V. ;
Nemec, B. ;
Jelinek, I. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) :517-526
[5]   Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry - An application for bioequivalence study [J].
Borges, NCD ;
Mendes, GD ;
Barrientos-Astigarraga, RE ;
Galvinas, P ;
Oliveira, CH ;
De Nucci, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02) :165-172
[6]   Quantitation of atenolol, metoprolol, and propranolol in postmortem human fluid and tissue specimens via LC/APCI-MS [J].
Johnson, RD ;
Lewis, RJ .
FORENSIC SCIENCE INTERNATIONAL, 2006, 156 (2-3) :106-117
[7]   Simultaneous determination of 6 beta-blockers, 3 calcium-channel antagonists, 4 angiotensin-II antagonists and 1 antiarrhytmic drug in post-mortem whole blood by automated solid phase extraction and liquid chromatography mass spectrometry - Method development and robustness testing by experimental design [J].
Kristoffersen, Lena ;
Oiestad, Elisabeth Leere ;
Opdal, Mimi Stokke ;
Krogh, Mette ;
Lundanes, Elsa ;
Christophersen, Asbjorg Solberg .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :147-160
[8]   Pharmacokinetics of an immediate release, a controlled release and a two pulse dosage form in dogs [J].
Löbenberg, R ;
Kim, JS ;
Amidon, GL .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2005, 60 (01) :17-23
[9]   A sensitive assay of metoprolol and its major metabolite α-hydroxy metoprolol in human plasma and determination of dextromethorphan and its metabolite dextrorphan in urine with high performance liquid chromatography and fluorometric detection [J].
Mistry, B ;
Leslie, J ;
Eddington, NE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (06) :1041-1049
[10]   Error structure for the HPLC analysis for atenolol, metoprolol and propranolol: a useful weighting method in parameter estimation [J].
Modamio, P ;
Lastra, CF ;
Marino, EL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) :507-513