Comparative Methods for Metal Artifact Reduction in x-ray CT

被引:0
作者
Abdoli, Mehrsima [1 ]
Mehranian, Abolfazl [2 ]
Ailianou, Angeliki [2 ]
Becker, Minerva [2 ]
Zaidi, Habib [2 ,3 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
来源
2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2014年
基金
瑞士国家科学基金会;
关键词
ATTENUATION CORRECTION; COMPUTED-TOMOGRAPHY; ALGORITHM; IMPLANTS; INTERPOLATION; SINOGRAMS;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To assess the performance of five metal artefact reduction (MAR) techniques for the assessment of computed tomography (CT) images of patients with hip prostheses. Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projections in the sinogram, two-dimensional interpolation (2D), a normalized metal artefact reduction (NMAR) technique, a metal deletion technique (MDT), and a 3D prior image constrained projection completion approach (MAPC). The algorithms were applied to 10 simulated datasets as well as30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded, experienced radiologists, who ranked overall artefact severity, as well as pelvic organ recognition for each algorithm, respectively. The simulated studies revealed that 2D, NMAR and MAPC techniques performed almost equally well in regions with dark streaking artefacts. However, in regions with bright streaking artefacts, LI outperformed the other techniques (p < 0.05). Visual assessment of clinical datasets confirmed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Overall, all methods performed equally well in artefact-free regions. However, NMAR and MAPC outperformed the other techniques in regions affected by artefacts.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
    Abdoli, Mehrsima
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3343 - 3360
  • [2] Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid
    Abdoli, Mehrsima
    de Jong, Johan R.
    Pruim, Jan
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (12) : 2257 - 2268
  • [3] Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2010, 37 (12) : 6166 - 6177
  • [4] Correction of CT artifacts and its influence on Monte Carlo dose calculations
    Bazalova, Magdalena
    Beaulieu, Luc
    Palefsky, Steven
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2119 - 2132
  • [5] Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
    Boas, F. Edward
    Fleischmann, Dominik
    [J]. RADIOLOGY, 2011, 259 (03) : 894 - 902
  • [6] Clough R.W., 1965, P C MATR METH STRUCT, P515
  • [7] Delaunay P., 1934, VESTN AN SSSR+, V6, P793
  • [8] AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS
    GLOVER, GH
    PELC, NJ
    [J]. MEDICAL PHYSICS, 1981, 8 (06) : 799 - 807
  • [9] COMPUTED TOMOGRAPHY RECONSTRUCTION FROM HOLLOW PROJECTIONS - APPLICATION TO INVIVO EVALUATION OF ARTIFICIAL HIP JOINTS
    HINDERLING, T
    RUEGSEGGER, P
    ANLIKER, M
    DIETSCHI, C
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) : 52 - 57
  • [10] REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS
    KALENDER, WA
    HEBEL, R
    EBERSBERGER, J