Modification of carbon paste with congo red supported on multi-walled carbon nanotube for voltammetric determination of uric acid in the presence of ascorbic acid

被引:25
作者
Shahrokhian, Saeed [1 ,2 ]
Zare-Mehrjardi, Hamid Reza [1 ]
Khajehsharifi, Habibollah [3 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[2] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
[3] Univ Yasuj, Fac Sci, Dept Chem, Yasuj 75914353, Iran
关键词
Carbon-paste electrode; Chemically modified electrode; Congo red; Multi-walled carbon nanotube; Uric acid; Ascorbic acid; ELECTROCHEMICAL SENSORS; MODIFIED ELECTRODE; CYTOCHROME-C; FUNCTIONALIZATION; BIOSENSORS; DOPAMINE; FILM; PURIFICATION; PEROXIDASE; ADSORPTION;
D O I
10.1007/s10008-008-0733-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A chemically modified carbon-paste electrode (CPE) is prepared by incorporating congo red (CR) immobilized on multi-walled carbon nanotube (MWCNT). The results show that CR is effectively immobilized on the surface of MWCNT under the ultrasonic agitation in aqueous solution and further incorporating the nafion. The prepared electrode, due to the electrostatic repulsions between the CR and ascorbate anion, is capable to mask the response of the ascorbic acid (AA) completely and provide an effective method for the detection of minor amounts of uric acid (UA) in the presence of high concentrations of AA. On the other hand, an increase in the microscopic area of the electrode by addition of MWCNT together with the electrocatalytic activity caused to a significant enhancement in the voltammetric response to UA. Optimization of the amounts of composite modifier in the matrix of CPE is performed by cyclic and differential pulse voltammetric measurements. The modified electrode shows a linear response to UA in the range of 1.0 x 10(-7)-1.0 x 10(-4) M with a detection limit of 1.0 x 10(-8) M. The electrode exhibits excellent accuracies for the determination of UA in the presence of high concentrations of AA (a recovery of 97.6%). The response of the electrode toward sulfhydryl compounds such as cysteine, penicillamine, and glutathione is not considerable. This reveals a good selectivity for the voltammetric response toward UA. The effective electrocatalytic property, ability for masking the voltammetric responses of the other biologically reducing agents, ease of preparation, and surface regeneration by simple polishing together with high reproducibility and stability of the responses make the modified electrode suitable for the selective and sensitive voltammetric detection of sub-micromolar amounts of UA in clinical and pharmaceutical preparations.
引用
收藏
页码:1567 / 1575
页数:9
相关论文
共 50 条
  • [31] Simultaneous voltammetric determination of uric acid and ascorbic acid using carbon paste/cobalt Schiff base composite electrode
    Mandana Amiri
    Abolfazl Bezaatpour
    Zohreh Pakdel
    Khadijeh Nekoueian
    Journal of Solid State Electrochemistry, 2012, 16 : 2187 - 2195
  • [32] Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode
    Beitollahi, Hadi
    Sheikhshoaie, Iran
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (02) : 336 - 342
  • [33] Carbon paste electrode incorporating multi-walled carbon nanotube/cobalt salophen for sensitive voltammetric determination of tryptophan
    Shahrokhian, Saeed
    Fotouhi, Leila
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02) : 942 - 949
  • [34] Electrochemical determination of tyrosine in the presence of uric acid at a carbon paste electrode modified with multi-walled carbon nanotubes enhanced by sodium dodecyl sulfate
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Delshad, Mona
    Khoobi, Asma
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (06): : 1824 - 1829
  • [35] Selective electrochemical determination of uric acid in the presence of ascorbic acid using a carbon paste electrode modified with β-cyclodextrin
    Ramirez-Berriozabal, Minerva
    Galicia, Laura
    Gutierrez-Granados, Silvia
    Cortes, Jose Sandoval
    Herrasti, Pilar
    ELECTROANALYSIS, 2008, 20 (15) : 1678 - 1683
  • [36] Electrochemical determination of levodopa in the presence of ascorbic acid by polyglycine/ZnO nanoparticles/multi-walled carbon nanotubes-modified carbon paste electrode
    Abbas Afkhami
    Fatemeh Kafrashi
    Tayyebeh Madrakian
    Ionics, 2015, 21 : 2937 - 2947
  • [37] Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Motghare, Ramani V.
    Tadi, Kiran Kumar
    Dhawale, Payal
    Deotare, Samiksha
    Kawadkar, Aruna K.
    Chillawar, Rakesh
    Khan, Shirinaz
    ELECTROANALYSIS, 2015, 27 (03) : 825 - 832
  • [38] Simultaneous detection of ascorbic acid, dopamine, uric acid and tryptophan with Azure A-interlinked multi-walled carbon nanotube/gold nanoparticles composite modified electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 (03) : 471 - 480
  • [39] Selective response of dopamine in the presence of ascorbic acid at multi-walled carbon nanotube modified gold electrode
    Zhang, P
    Wu, FH
    Zhao, GC
    Wei, XW
    BIOELECTROCHEMISTRY, 2005, 67 (01) : 109 - 114
  • [40] Voltammetric determination of silver with a new multi-walled carbon nanotube modified paste electrode
    Somayye Cheraghi
    Mohammad Ali Taher
    Hamid Fazelirad
    Russian Journal of Electrochemistry, 2015, 51 : 271 - 277