Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses

被引:7
作者
Walther, Hendrik [1 ]
Subbaraman, Lakshman N. [1 ]
Jones, Lyndon [1 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, CORE, Waterloo, ON, Canada
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2019年 / 45卷 / 02期
关键词
Lipid deposition; Silicone hydrogel; Contact lenses; Cholesterol; Cleaning; Multipurpose solution; TEAR FILM COMPONENTS; IN-VITRO; PROTEIN DEPOSITION; LIPID DEPOSITION; LYSOZYME DEPOSITION; BACTERIAL ADHESION; IMPACT; QUANTIFICATION; SURFACE; RUB;
D O I
10.1097/ICL.0000000000000547
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model. Materials and Methods: Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37 degrees C in an artificial tear solution containing C-14 radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform: methanol, analyzed in a beta counter, and mu g/lens of cholesterol was determined. Results: Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93 +/- 0.02 mu g/lens; 0.95 +/- 0.01 mu g/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37 +/- 0.03 mu g/lens; 0.47 +/- 0.12 mu g/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05). Conclusion: Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 77 条
[1]   GIANT PAPILLARY CONJUNCTIVITIS IN CONTACT-LENS WEARERS [J].
ALLANSMITH, MR ;
KORB, DR ;
GREINER, JV ;
HENRIQUEZ, AS ;
SIMON, MA ;
FINNEMORE, VM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 83 (05) :697-708
[2]   Oxygen permeability of a new type of high Dk soft contact lens material [J].
Alvord, L ;
Court, J ;
Davis, T ;
Morgan, CF ;
Schindhelm, K ;
Vogt, J ;
Winterton, L .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (01) :30-36
[3]  
ASWAD MI, 1990, OPHTHALMOLOGY, V97, P296
[4]  
Bontempo Andrew R., 2001, CLAO Journal, V27, P75
[5]   Protein-lipid interaction on the surface of a hydrophilic contact lens in vitro [J].
Bontempo, AR ;
Rapp, J .
CURRENT EYE RESEARCH, 1997, 16 (08) :776-781
[6]  
Butcko V, 2007, EYE CONTACT LENS, V33, P4
[7]  
Butcko Victoria, 2007, Eye Contact Lens, V33, P421, DOI 10.1097/ICL.0b013e318157f3df
[8]   The adsorption of major tear film lipids in vitro to various silicone hydrogels over time [J].
Carney, Fiona P. ;
Nash, Walter L. ;
Sentell, Karen B. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (01) :120-124
[9]   Soft contact lens cleaning: rub or no-rub? [J].
Cho, Pauline ;
Cheng, Suk Yi ;
Chan, Wai Yip ;
Yip, Wing Kin .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (01) :49-57
[10]  
Christensen B., 1998, Int Contact Lens Clin, V25, P50