A comparison of 2D and 3D digital image correlation for a membrane under inflation

被引:27
作者
Murienne, Barbara J. [1 ]
Nguyen, Thao D. [1 ]
机构
[1] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
关键词
Digital image correlation; 3D full-field measurements; 2D profile measurements; Mechanical testing; Inflation; BULGE TEST; THIN-FILMS; SINGLE CAMERA; BIOMECHANICS; SCLERA; MICROSCOPE; TISSUES; VISION; MOTION;
D O I
10.1016/j.optlaseng.2015.07.013
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Three-dimensional (3D) digital image correlation (DIC) is becoming widely used to characterize the behavior of structures undergoing 3D deformations. However, the use of 3D-DIC can be challenging under certain conditions, such as high magnification, and therefore small depth of field, or a highly controlled environment with limited access for two-angled cameras. The purpose of this study is to compare 2D-DIC and 3D-DIC for the same inflation experiment and evaluate whether 2D-DIC can be used when conditions discourage the use of a stereo-vision system. A latex membrane was inflated vertically to 5.41 kPa (reference pressure), then to 7.87 kPa (deformed pressure). A two-camera stereo-vision system acquired top-down images of the membrane, while a single camera system simultaneously recorded images of the membrane in profile. 2D-DEC and 3D-DIC were used to calculate horizontal (in the membrane plane) and vertical (out of the membrane plane) displacements, and meridional strain. Under static conditions, the baseline uncertainty in horizontal displacement and strain were smaller for 3D-DIC than 2D-DIC. However, the opposite was observed for the vertical displacement, for which 2D-DIC had a smaller baseline uncertainty. The baseline absolute error in vertical displacement and strain were similar for both DIC methods, but it was larger for 2D-DIC than 3D-DIC for the horizontal displacement. Under inflation, the variability in the measurements were larger than under static conditions for both DIC methods. 2D-DIC showed a smaller variability in displacements than 3D-DIC, especially for the vertical displacement, but a similar strain uncertainty. The absolute difference in the average displacements and strain between 3D-DIC and 2D-DIC were in the range of the 3D-DIC variability. Those findings suggest that 2D-DIC might be used as an alternative to 3D-DIC to study the inflation response of materials under certain conditions. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 39 条
[1]   Error estimations of 3D digital image correlation measurements [J].
Becker, Thomas ;
Splitthof, Karsten ;
Siebert, Thorsten ;
Kletting, Peter .
SPECKLE06: SPECKLES, FROM GRAINS TO FLOWERS, 2006, 6341
[2]   Mechanical assessment of suspended ALD thin films by bulge and shaft-loading techniques [J].
Berdova, Maria ;
Ylitalo, Tuomo ;
Kassamakov, Ivan ;
Heino, Jouni ;
Torma, Pekka T. ;
Kilpi, Lauri ;
Ronkainen, Helena ;
Koskinen, Jari ;
Haeggstrom, Edward ;
Franssila, Sami .
ACTA MATERIALIA, 2014, 66 :370-377
[3]   Cancelling bias induced by correlation coefficient interpolation for sub-pixel image registration [J].
Cheng, Peng ;
Menq, Chia-Hsiang .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (03)
[4]   Biomechanics of the Human Posterior Sclera: Age- and Glaucoma-Related Changes Measured Using Inflation Testing [J].
Coudrillier, Baptiste ;
Tian, Jing ;
Alexander, Stephen ;
Myers, Kristin M. ;
Quigley, Harry A. ;
Nguyen, Thao D. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) :1714-1728
[5]   Stereo-Digital Image Correlation (DIC) measurements with a single camera using a biprism [J].
Genovese, K. ;
Casaletto, L. ;
Rayas, J. A. ;
Flores, V. ;
Martinez, Amalia .
OPTICS AND LASERS IN ENGINEERING, 2013, 51 (03) :278-285
[6]   Scleral Biomechanics in the Aging Monkey Eye [J].
Girard, Michael J. A. ;
Suh, J. -K. Francis ;
Bottlang, Michael ;
Burgoyne, Claude F. ;
Downs, J. Crawford .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (11) :5226-5237
[7]   Use of rigid-body motion for the investigation and estimation of the measurement errors related to digital image correlation technique [J].
Haddadi, H. ;
Belhabib, S. .
OPTICS AND LASERS IN ENGINEERING, 2008, 46 (02) :185-196
[8]   Fluorescent stereo microscopy for 3D surface profilometry and deformation mapping [J].
Hu, Zhenxing ;
Luo, Huiyang ;
Du, Yingjie ;
Lu, Hongbing .
OPTICS EXPRESS, 2013, 21 (10) :11808-11818
[9]   Error evaluation technique for three-dimensional digital image correlation [J].
Hu, Zhenxing ;
Xie, Huimin ;
Lu, Jian ;
Wang, Huaixi ;
Zhu, Jianguo .
APPLIED OPTICS, 2011, 50 (33) :6239-6247
[10]   Mechanical properties of polymer thin film measured by the bulge test [J].
Huang, C. K. ;
Lou, W. M. ;
Tsai, C. J. ;
Tung-Chuan, Wu B. ;
Lin, Hung-Yi .
THIN SOLID FILMS, 2007, 515 (18) :7222-7226