Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation

被引:21
|
作者
Lee, Joonnyong [1 ]
Sohn, JangJay [1 ]
Park, Jonghyun [1 ]
Yang, SeungMan [1 ]
Lee, Saram [2 ]
Kim, Hee Chan [3 ,4 ]
机构
[1] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Bioengn, Suite 321,Bldg 8,101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ Hosp, Biomed Res Inst, Suite 1203-1,71 Daehak Ro, Seoul 03082, South Korea
[3] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Suite 11315,101 Daehak Ro, Seoul 03080, South Korea
[4] Seoul Natl Univ, Inst Med & Biol Engn, Med Res Ctr, Suite 11315,101 Daehak Ro, Seoul 03080, South Korea
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
基金
新加坡国家研究基金会;
关键词
Blood pressure; Pulse pressure; Stroke volume; Pre-ejection period; Pulse transit time; Ubiquitous healthcare; TOTAL ARTERIAL COMPLIANCE; CORONARY-HEART-DISEASE; CARDIOVASCULAR RISK; ARRIVAL-TIME; HYPERTENSION; BALLISTOCARDIOGRAM; VARIABILITY; RATIO; ABNORMALITIES; POPULATION;
D O I
10.1186/s12938-018-0510-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension, but not enough attention has been given to non-invasive continuous monitoring of pulse pressure. Although accurate pulse pressure estimation can be of direct value to hypertension management and indirectly to the estimation of systolic blood pressure, as it is the sum of pulse pressure and diastolic blood pressure, only a few inadequate methods of pulse pressure estimation have been proposed. Methods: We present a novel, non-invasive blood pressure and pulse pressure estimation method based on pulse transit time and pre-ejection period. Pre-ejection period and pulse transit time were measured non-invasively using electrocardiogram, seismocardiogram, and photoplethysmogram measured from the torso. The proposed method used the 2-element Windkessel model to model pulse pressure with the ratio of stroke volume, approximated by pre-ejection period, and arterial compliance, estimated by pulse transit time. Diastolic blood pressure was estimated using pulse transit time, and systolic blood pressure was estimated as the sum of the two estimates. The estimation method was verified in 11 subjects in two separate conditions with induced cardiovascular response and the results were compared against a reference measurement and values obtained from a previously proposed method. Results: The proposed method yielded high agreement with the reference (pulse pressure correlation with reference R >= 0.927, diastolic blood pressure correlation with reference R >= 0.854, systolic blood pressure correlation with reference R >= 0.914) and high estimation accuracy in pulse pressure (mean root-mean-squared error <= 3.46 mmHg) and blood pressure (mean root-mean-squared error <= 6.31 mmHg for diastolic blood pressure and <= 8.41 mmHg for systolic blood pressure) over a wide range of hemodynamic changes. Conclusion: The proposed pulse pressure estimation method provides accurate estimates in situations with and without significant changes in stroke volume. The proposed method improves upon the currently available systolic blood pressure estimation methods by providing accurate pulse pressure estimates.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [42] Blood pressure monitoring during exercise: Comparison of pulse transit time and volume clamp methods
    Wibmer, Thomas
    Denner, Coy
    Fischer, Christoph
    Schildge, Benedikt
    Ruediger, Stefan
    Kropf-Sanchen, Cornelia
    Rottbauer, Wolfgang
    Schumann, Christian
    BLOOD PRESSURE, 2015, 24 (06) : 353 - 360
  • [43] Development of a Continuous Blood Pressure Monitoring System based on Pulse Transit Time and Hemodynamic Covariates
    Zhang, Yiming
    Zhou, Congcong
    Huang, Zhongyi
    Ye, Xuesong
    BIODEVICES: PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 1: BIODEVICES, 2020, 2020, : 33 - 39
  • [44] Continuous Cuffless Blood Pressure Estimation Based on Pulse Transit Time: A New Evaluation with Invasive BP Reference
    Tang, Zunyi
    Chen, Ying
    Liu, Shing-Hong
    Kobayashi, Toshio
    Chen, Wenxi
    2019 IEEE 10TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST 2019), 2019, : 516 - 520
  • [45] The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects
    Wong, Mico Yee-Man
    Pickwell-MacPherson, Emma
    Zhang, Yuan-Ting
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (02) : 169 - 175
  • [46] Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
    Ding, Xiao-Rong
    Zhang, Yuan-Ting
    Liu, Jing
    Dai, Wen-Xuan
    Tsang, Hon Ki
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) : 964 - 972
  • [47] Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar
    Buxi, Dilpreet
    Redout, Jean-Michel
    Yuce, Mehmet Rasit
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) : 917 - 927
  • [48] Comparative evaluation of stroke volume variation measured by pulse wave transit time and arterial pressure wave
    Ochiai, Ryoichi
    Terada, Takashi
    Sakamoto, Noriaki
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (02) : 651 - 662
  • [49] Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates
    Jingjie Feng
    Zhongyi Huang
    Congcong Zhou
    Xuesong Ye
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 403 - 413
  • [50] Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors
    Dias, Alair, Jr.
    Murali, Srinivasan
    Rincon, Francisco
    Atienza, David
    MICROPROCESSORS AND MICROSYSTEMS, 2016, 46 : 84 - 95