Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation

被引:21
|
作者
Lee, Joonnyong [1 ]
Sohn, JangJay [1 ]
Park, Jonghyun [1 ]
Yang, SeungMan [1 ]
Lee, Saram [2 ]
Kim, Hee Chan [3 ,4 ]
机构
[1] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Bioengn, Suite 321,Bldg 8,101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ Hosp, Biomed Res Inst, Suite 1203-1,71 Daehak Ro, Seoul 03082, South Korea
[3] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Suite 11315,101 Daehak Ro, Seoul 03080, South Korea
[4] Seoul Natl Univ, Inst Med & Biol Engn, Med Res Ctr, Suite 11315,101 Daehak Ro, Seoul 03080, South Korea
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
基金
新加坡国家研究基金会;
关键词
Blood pressure; Pulse pressure; Stroke volume; Pre-ejection period; Pulse transit time; Ubiquitous healthcare; TOTAL ARTERIAL COMPLIANCE; CORONARY-HEART-DISEASE; CARDIOVASCULAR RISK; ARRIVAL-TIME; HYPERTENSION; BALLISTOCARDIOGRAM; VARIABILITY; RATIO; ABNORMALITIES; POPULATION;
D O I
10.1186/s12938-018-0510-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension, but not enough attention has been given to non-invasive continuous monitoring of pulse pressure. Although accurate pulse pressure estimation can be of direct value to hypertension management and indirectly to the estimation of systolic blood pressure, as it is the sum of pulse pressure and diastolic blood pressure, only a few inadequate methods of pulse pressure estimation have been proposed. Methods: We present a novel, non-invasive blood pressure and pulse pressure estimation method based on pulse transit time and pre-ejection period. Pre-ejection period and pulse transit time were measured non-invasively using electrocardiogram, seismocardiogram, and photoplethysmogram measured from the torso. The proposed method used the 2-element Windkessel model to model pulse pressure with the ratio of stroke volume, approximated by pre-ejection period, and arterial compliance, estimated by pulse transit time. Diastolic blood pressure was estimated using pulse transit time, and systolic blood pressure was estimated as the sum of the two estimates. The estimation method was verified in 11 subjects in two separate conditions with induced cardiovascular response and the results were compared against a reference measurement and values obtained from a previously proposed method. Results: The proposed method yielded high agreement with the reference (pulse pressure correlation with reference R >= 0.927, diastolic blood pressure correlation with reference R >= 0.854, systolic blood pressure correlation with reference R >= 0.914) and high estimation accuracy in pulse pressure (mean root-mean-squared error <= 3.46 mmHg) and blood pressure (mean root-mean-squared error <= 6.31 mmHg for diastolic blood pressure and <= 8.41 mmHg for systolic blood pressure) over a wide range of hemodynamic changes. Conclusion: The proposed pulse pressure estimation method provides accurate estimates in situations with and without significant changes in stroke volume. The proposed method improves upon the currently available systolic blood pressure estimation methods by providing accurate pulse pressure estimates.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Evaluation of the Correlation Between Blood Pressure and Pulse Transit Time
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 17 - 20
  • [32] A Camera-Based Pulse Transit Time Estimation Approach Towards Non-Intrusive Blood Pressure Monitoring
    Patil, Omkar R.
    Wang, Wei
    Gao, Yang
    Jin, Zhanpeng
    2019 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI), 2019, : 257 - 266
  • [33] An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects
    Wong, Mico Yee-Man
    Poon, Carmen Chung-Yan
    Zhang, Yuan-Ting
    CARDIOVASCULAR ENGINEERING, 2009, 9 (01) : 32 - 38
  • [34] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [35] A novel Blood Pressure estimation method combing Pulse Wave Transit Time model and neural network model
    Xu, Jun
    Jiang, Jiehui
    Zhou, Hucheng
    Yan, Zhuangzhi
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2130 - 2133
  • [36] Contribution of stroke volume to the change in pulse pressure pattern with age
    Alfie, J
    Waisman, GD
    Galarza, CR
    Cámera, MI
    HYPERTENSION, 1999, 34 (04) : 808 - 812
  • [37] PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE AND MYOCARDIAL PERFORMANCE
    OBRIST, PA
    LIGHT, KC
    MCCUBBIN, JA
    HUTCHESON, JS
    HOFFER, JL
    PSYCHOPHYSIOLOGY, 1979, 16 (03) : 292 - 301
  • [38] Towards Ubiquitous Blood Pressure Monitoring in an Armband using Pulse Transit Time
    Toreyin, Hakan
    Javaid, Abdul Q.
    Ashouri, Hazar
    Ode, Oludotun
    Inan, Omer T.
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 560 - 563
  • [39] Adaptive Algorithm for Continuous Monitoring of Blood Pressure Using a Pulse Transit Time
    Jadooei, Ali
    Zaderykhin, O.
    Shulgin, V. I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 297 - 301
  • [40] Implantable Reflectance Pulse Transit Time Blood Pressure Sensor with Oximetry Capability
    Fiala, J.
    Gehrke, R.
    Theodor, M.
    Bingger, P.
    Frster, K.
    Heilmann, C.
    Beyersdorf, F.
    Zappe, H.
    Seifert, A.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715