Instantaneous responses to high-frequency chest wall oscillation in patients with acute pneumonic respiratory failure receiving mechanical ventilation A randomized controlled study

被引:10
|
作者
Chuang, Ming-Lung [1 ,2 ,3 ]
Chou, Yi-Ling [2 ,4 ]
Lee, Chai-Yuan [4 ]
Huang, Shih-Feng [1 ,2 ,3 ]
机构
[1] Chung Shan Med Univ Hosp, Div Pulm Med, Taichung 40201, Taiwan
[2] Chung Shan Med Univ Hosp, Dept Crit Care Med, Taichung 40201, Taiwan
[3] Chung Shan Med Univ Hosp, Sch Med, Taichung 40201, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Nursing, Taichung 40201, Taiwan
关键词
acute respiratory failure; chest physiotherapy; high-frequency chest wall oscillation; mechanical ventilatory support; AIRWAY CLEARANCE; COMPRESSIONS; THERAPY; DISEASE;
D O I
10.1097/MD.0000000000005912
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Endotracheal intubation and prolonged immobilization of patients receiving mechanical ventilation may reduce expectoration function. High-frequency chest wall oscillation (HFCWO) may ameliorate airway secretion movement; however, the instantaneous changes in patients' cardiopulmonary responses are unknown. Moreover, HFCWO may influence ventilator settings by the vigorous oscillation. The aim of this study was to investigate these issues. Methods: Seventy-three patients (52 men) aged 71.5 +/- 13.4 years who were intubated with mechanical ventilation for pneumonic respiratory failure were recruited and randomly classified into 2 groups (HFCWO group, n=36; and control group who received conventional chest physical therapy (CCPT, n=37). HFCWO was applied with a fixed protocol, whereas CCPT was conducted using standard protocols. Both groups received sputum suction after the procedure. Changes in ventilator settings and the subjects' responses were measured at preset intervals and compared within groups and between groups. Results: Oscillation did not affect the ventilator settings (all P>0.05). The mean airway pressure, breathing frequency, and rapid shallow breathing index increased, and the tidal volume and SpO(2) decreased (all P<0.05). After sputum suction, the peak airway pressure (P-peak) and minute ventilation decreased (all P<0.05). The HFCWO group had a lower tidal volume and SpO2 at the end of oscillation, and lower Ppeak and tidal volume after sputum suction than the CCPT group. Conclusions: HFCWO affects breathing pattern and SpO2 but not ventilator settings, whereas CCPT maintains a steadier condition. After sputum suction, HFCWO slightly improved Ppeak compared to CCPT, suggesting that the study extends the indications of HFCWO for these patients in intensive care unit. (ClinicalTrials.gov number NCT02758106, retrospectively registered.)
引用
收藏
页数:8
相关论文
共 50 条
  • [1] High-frequency chest wall oscillation in prolonged mechanical ventilation patients: a randomized controlled trial
    Huang, Wei-Chang
    Wu, Pi-Chu
    Chen, Chao-Jung
    Cheng, Ya-Hua
    Shih, Sou-Jen
    Chen, Hui-Chen
    Wu, Chieh-Liang
    CLINICAL RESPIRATORY JOURNAL, 2016, 10 (03): : 272 - 281
  • [2] Effectiveness of treatment with high-frequency chest wall oscillation in patients with bronchiectasis
    Nicolini, Antonello
    Cardini, Federica
    Landucci, Norma
    Lanata, Sergio
    Ferrari-Bravo, Maura
    Barlascini, Cornelius
    BMC PULMONARY MEDICINE, 2013, 13
  • [3] High-frequency percussive ventilation improves oxygenation and ventilation in pediatric patients with acute respiratory failure
    Rizkalla, Nicole A.
    Dominick, Cheryl L.
    Fitzgerald, Julie C.
    Thomas, Neal J.
    Yehya, Nadir
    JOURNAL OF CRITICAL CARE, 2014, 29 (02) : 314.e1 - 314.e7
  • [4] Effectiveness of treatment with high-frequency chest wall oscillation in patients with bronchiectasis
    Antonello Nicolini
    Federica Cardini
    Norma Landucci
    Sergio Lanata
    Maura Ferrari-Bravo
    Cornelius Barlascini
    BMC Pulmonary Medicine, 13
  • [5] High-frequency percussive ventilation in acute respiratory failure
    Bruni, Andrea
    Neri, Giuseppe
    Cammarota, Gianmaria
    Bosco, Vincenzo
    Biamonte, Eugenio
    Troisi, Letizia
    Boscolo, Annalisa
    Navalesi, Paolo
    Longhini, Federico
    Garofalo, Eugenio
    ERJ OPEN RESEARCH, 2024, 10 (06)
  • [6] Safety and effectiveness of the high-frequency chest wall oscillation vs intrapulmonary percussive ventilation in patients with severe COPD
    Nicolini, Antonello
    Grecchi, Bruna
    Ferrari-Bravo, Maura
    Barlascini, Cornelius
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 617 - 625
  • [7] High-Frequency Percussive Ventilation in Cystic Fibrosis Patients With Acute Respiratory Failure: A Case Series
    Jandali, Badr
    Mermis, Joel D.
    Crosser, Michael S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (07)
  • [8] Safety, Tolerability, and Efficacy of High-Frequency Chest Wall Oscillation in Pediatric Patients With Cerebral Palsy and Neuromuscular Diseases: An Exploratory Randomized Controlled Trial
    Yuan, Nanci
    Kane, Peter
    Shelton, Kristen
    Matel, Julie
    Becker, Brian C.
    Moss, Richard B.
    JOURNAL OF CHILD NEUROLOGY, 2010, 25 (07) : 815 - 821
  • [9] High-Frequency Chest Wall Oscillation in Patients with COVID-19: A Pilot Feasibility Study
    Celik, Mine
    Yayik, Ahmet Murat
    Kerget, Bugra
    Kerget, Ferhan
    Doymus, Omer
    Aksakal, Alperen
    Ozmen, Sevilay
    Aslan, Mehtap Hulya
    Uzun, Yakup
    EURASIAN JOURNAL OF MEDICINE, 2022, 54 (02): : 150 - 156
  • [10] High-frequency oscillatory ventilation with partial liquid ventilation in a model of acute respiratory failure
    Baden, HP
    Mellema, JD
    Bratton, SL
    ORourke, PP
    Jackson, JC
    CRITICAL CARE MEDICINE, 1997, 25 (02) : 299 - 302