Quantitative static Time-of-Flight Secondary Ion Mass Spectrometry analysis of anionic minority species in microelectronic substrates

被引:2
|
作者
Ravanel, X. [1 ,2 ]
Trouiller, C. [1 ]
Juhel, M. [1 ]
Wyon, C. [3 ]
Kwakman, L. F. Tz. [4 ]
Leonard, D. [2 ]
机构
[1] STMicroelectronics, F-38926 Crolles, France
[2] Univ Lyon 1, CNRS, UMR 5180, Sci Analyt Lab, F-69622 Villeurbanne, France
[3] CEA, LETI Minatec, F-38054 Grenoble, France
[4] NXP Semicond, F-38920 Crolles, France
关键词
Static Time-of-Flight SIMS; Quantification; Anionic species; RSF; Detection limit;
D O I
10.1016/j.apsusc.2008.06.045
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Reliability and yield of nano-electronic devices can be seriously affected by the presence of surface contamination, even at low concentration. The microelectronics industry is, thus, in need for a quantitative, highly sensitive surface analysis technique capable of detecting both elementary and molecular species present at the surface. Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) provides a submicronic lateral resolution and excellent sensitivity with high secondary ion yields on a broad mass range but, nevertheless, remains a qualitative technique. To convert normalized ion intensities into concentrations and, thus, to provide reliable quanti. cation, the so-called relative sensitivity factors (RSFs) need to be determined. In earlier studies, ToF-SIMS RSFs for trace metals were determined from the calibration of ToF-SIMS positive ion intensities against quantitative analysis techniques able to determine a surface coverage such as vapour phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) or total reflection X-ray fluorescence (TXRF) results. Here, the aim is to quantify elementary anionic minority species (S, Cl, P, Br). Deliberately contaminated samples were prepared and analyzed with ToF-SIMS and several quantitative surface analytical techniques like TXRF, liquid phase extraction ionic chromatography (LPE-IC) or VPD-ICP-MS. None of these latter techniques can by itself successfully handle all the anionic species cases and ToF-SIMS turns out to be the more versatile and precise characterization technique in this context. (C) 2008 Elsevier B. V. All rights reserved.
引用
收藏
页码:1415 / 1418
页数:4
相关论文
共 50 条
  • [21] Quantitative analysis of lipids with argon gas cluster ion beam secondary ion mass spectrometry
    Fujii, Makiko
    Nakagawa, Shunichirou
    Seki, Toshio
    Aoki, Takaaki
    Matsuo, Jiro
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (12-13) : 1129 - 1132
  • [22] Quantitative depth profiling of ultrathin high-k stacks with full spectrum time of flight-secondary ion mass spectrometry
    Py, Matthieu
    Barnes, Jean-Paul
    Boujamaa, Rachid
    Gros-Jean, Michael
    Nakajima, Kaoru
    Kimura, Kenji
    Roukoss, Charbel
    Pelissier, Bernard
    Gambacorti, Narciso
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2011, 29 (03):
  • [23] Simultaneous Qualitative and Quantitative Analysis of Multiple Chemical Constituents in YiQiFuMai Injection by Ultra-Fast Liquid Chromatography Coupled with Ion Trap Time-of-Flight Mass Spectrometry
    Liu, Chunhua
    Ju, Aichun
    Zhou, Dazheng
    Li, Dekun
    Kou, Junping
    Yu, Boyang
    Qi, Jin
    MOLECULES, 2016, 21 (05):
  • [24] Application of electrospray ionization ion trap/time-of-flight mass spectrometry for chemically-synthesized small RNAs
    Izumi, Yoshihiro
    Takimura, Shin
    Yamaguchi, Shinichi
    Iida, Junko
    Bamba, Takeshi
    Fukusaki, Eiichiro
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2012, 113 (03) : 412 - 419
  • [25] Quantitative aspects in electrospray ionization ion trap and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of malto-oligosaccharides
    Unterieser, Inga
    Cuers, Julia
    Voiges, Kristin
    Enebro, Jonas
    Mischnick, Petra
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (15) : 2201 - 2208
  • [26] Rapid screening of abused drugs by direct analysis in real time (DART) coupled to time-of-flight mass spectrometry (TOF-MS) combined with ion mobility spectrometry (IMS)
    Lian, Ru
    Wu, Zhongping
    Lv, Xiaobao
    Rao, Yulan
    Li, Haiyang
    Li, Jinghua
    Wang, Rong
    Ni, Chunfang
    Zhang, Yurong
    FORENSIC SCIENCE INTERNATIONAL, 2017, 279 : 268 - 280
  • [27] Untargeted screening of secondary metabolites in fungal cultures and samples from mouldy indoor environments by time-of-flight mass spectrometry
    Malysheva, S. V.
    Polizzi, V.
    Moretti, A.
    Van Peteghem, C.
    De Kimpe, N.
    Van Bocxlaer, J.
    Di Mavungu, J. Diana
    De Saeger, S.
    WORLD MYCOTOXIN JOURNAL, 2014, 7 (01) : 35 - 44
  • [28] Liquid chromatography/time-of-flight mass spectrometry analysis of postmortem blood samples for targeted toxicological screening
    Roman, Markus
    Strom, Lena
    Tell, Helena
    Josefsson, Martin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4107 - 4125
  • [29] Multi-Residue Analysis of Pesticides in Agricultural Products by Liquid Chromatography Time-of-Flight Mass Spectrometry
    Saito, Shizuka
    Nemoto, Satoru
    Matsuda, Rieko
    FOOD HYGIENE AND SAFETY SCIENCE, 2012, 53 (06): : 255 - 263
  • [30] Analysis of Inorganic Nanoparticles by Single-particle Inductively Coupled Plasma Time-of-Flight Mass Spectrometry
    Hendriks, Lyndsey
    Gundlach-Graham, Alexander
    Guenther, Detlef
    CHIMIA, 2018, 72 (04) : 221 - 226