Movement quality of conventional prostheses and the DEKA Arm during everyday tasks

被引:28
作者
Cowley, Jeffrey [1 ]
Resnik, Linda [2 ]
Wilken, Jason [3 ]
Smurr Walters, Lisa [3 ]
Gates, Deanna [1 ]
机构
[1] Univ Michigan, 401 Washtenaw Ave, Ann Arbor, MI 48109 USA
[2] Providence VA Med Ctr, Providence, RI USA
[3] Brooke Army Med Ctr, San Antonio, TX USA
基金
美国国家卫生研究院;
关键词
Biomechanics in neuromuscular disorders; prosthetic design; testing of prosthetic and orthotic components; upper limb prosthetics; PERFORMANCE; STROKE; MOTION; USER; COORDINATION; ACCURACY; ENERGY; HAND; VA;
D O I
10.1177/0309364616631348
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Conventional prosthetic devices fail to restore the function and characteristic movement quality of the upper limb. The DEKA Arm is a new, advanced prosthesis featuring a compound, powered wrist and multiple grip configurations. Objectives: The purpose of this study was to determine if the DEKA Arm improved the movement quality of upper limb prosthesis users compared to conventional prostheses. Study design: Case series. Methods: Three people with transradial amputation completed tasks of daily life with their conventional prosthesis and with the DEKA Arm. A total of 10 healthy controls completed the same tasks. The trajectory of the wrist joint center was analyzed to determine how different prostheses affected movement duration, speed, smoothness, and curvature compared to patients' own intact limbs and controls. Results: Movement quality decreased with the DEKA Arm for two participants, and increased for the third. Prosthesis users made slower, less smooth, more curved movements with the prosthetic limb compared to the intact limb and controls, particularly when grasping and manipulating objects. Conclusion: The effects of one month of training with the DEKA Arm on movement quality varied with participants' skill and experience with conventional prostheses. Future studies should examine changes in movement quality after long-term use of advanced prostheses. Clinical relevance Movement quality with the DEKA Arm may depend on the user's previous experience with conventional prostheses. Quantitative analyses are needed to assess the efficacy of novel prosthetic devices and to better understand how to train people to use them effectively.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 35 条
[1]   Impact of impaired wrist motion on hand and upper-extremity performance [J].
Adams, BD ;
Grosland, NM ;
Murphy, DM ;
McCullough, M .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (06) :898-903
[2]   Upper-limb prosthetics - Critical factors in device abandonment [J].
Biddiss, Elaine ;
Chau, Tom .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2007, 86 (12) :977-987
[3]  
Black N, 2005, ROBOTICA, V23, P319, DOI [10.1017/S0263574704001341, 10.1017/S026357470400134]
[4]   Determining skill level in myoelectric prosthesis use with multiple outcome measures [J].
Bouwsema, Hanneke ;
Kyberd, Peter J. ;
Hill, Wendy ;
van der Sluis, Corry K. ;
Bongers, Raoul M. .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (09) :1331-1347
[5]   Movement characteristics of upper extremity prostheses during basic goal-directed tasks [J].
Bouwsema, Hanneke ;
van der Sluis, Corry K. ;
Bongers, Raoul M. .
CLINICAL BIOMECHANICS, 2010, 25 (06) :523-529
[6]   Compensatory movements of transradial prosthesis users during common tasks [J].
Carey, Stephanie L. ;
Highsmith, M. Jason ;
Maitland, Murray E. ;
Dubey, Rajiv V. .
CLINICAL BIOMECHANICS, 2008, 23 (09) :1128-1135
[7]   PERFORMANCE OF ABOVE ELBOW BODY-POWERED PROSTHESES IN VISUALLY GUIDED UNCONSTRAINED MOTION TASKS [J].
DOERINGER, JA ;
HOGAN, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) :621-631
[8]   Abnormal cognitive planning and movement smoothness control for a complex shoulder/elbow motor task in stroke survivors [J].
Fang, Yin ;
Yue, Guang H. ;
Hrovat, Kenneth ;
Sahgal, Vinod ;
Daly, Janis J. .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2007, 256 (1-2) :21-29
[9]   THE COORDINATION OF ARM MOVEMENTS - AN EXPERIMENTALLY CONFIRMED MATHEMATICAL-MODEL [J].
FLASH, T ;
HOGAN, N .
JOURNAL OF NEUROSCIENCE, 1985, 5 (07) :1688-1703
[10]  
FRASER C, 1981, PROSTHET ORTHOT INT, V5, P151