Sensitive detection of Pb(II) at gold nanoparticle/polyaniline/graphene modified electrode using differential pulse anodic stripping voltammetry

被引:50
作者
Dong, YongPing [1 ]
Zhou, Ying [1 ]
Ding, Yong [1 ]
Chu, XiangFeng [1 ]
Wang, ChengMing [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243002, Peoples R China
[2] Univ Sci & Technol China, Hefei Natl Lab Phys Sci Microscale, Hefei 230026, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
WALLED CARBON NANOTUBES; FILM ELECTRODE; HYBRID SYSTEMS; GRAPHENE OXIDE; THIN-FILMS; METAL-IONS; POLYANILINE; COMPOSITES; NANOPARTICLES; POLYPYRROLE;
D O I
10.1039/c4ay01908c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a gold nanoparticle/polyaniline/graphene ternary nanocomposite modified glassy carbon electrode (GNP/PANI/GR/GCE) was prepared and characterized by scanning electron microscopy, spectroscopic techniques, and electrochemical techniques. It was found that the GNP/PANI/GR nanocomposite exhibited a good synergetic effect on the electrochemical signal from Pb2+, which is more efficient than that of electrodes modified with the individual materials. The modified electrode could be applied in the sensitive detection of Pb2+ by differential pulse anodic stripping voltammetry (DPASV). Several experimental parameters, such as the ratio of aniline/graphene, the amount of suspension modified on the electrode, the pH, the diameter of gold nanoparticles, the deposition time, and the potential of Pb2+ were optimized. Under the optimal conditions, a good linear relationship between the stripping peak currents and the concentration of Pb2+ was obtained in the range of 0.5 to 10 nM with a correlation coefficient of 0.9995 and a detection limit of 0.1 nM. The proposed method is applicable in the determination of trace Pb2+ in real water samples with a relative standard deviation less than 3.5% and recovery rates of similar to 99%.
引用
收藏
页码:9367 / 9374
页数:8
相关论文
共 41 条
[11]   Composites of intrinsically conducting polymers as sensing nanomaterials [J].
Hatchett, David W. ;
Josowicz, Mira .
CHEMICAL REVIEWS, 2008, 108 (02) :746-769
[12]   PREPARATION OF GRAPHITIC OXIDE [J].
HUMMERS, WS ;
OFFEMAN, RE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1958, 80 (06) :1339-1339
[13]   Heavy metal poisoning: the effects of cadmium on the kidney [J].
Johri, Nikhil ;
Jacquillet, Gregory ;
Unwin, Robert .
BIOMETALS, 2010, 23 (05) :783-792
[14]   Determination by AAS of some trace heavy metal ions in some natural and biological samples after their preconcentration using newly chemically modified chloromethylated polystyrene-PAN ion-exchanger [J].
Kenawy, IMM ;
Hafez, MAH ;
Akl, MA ;
Lashein, RR .
ANALYTICAL SCIENCES, 2000, 16 (05) :493-500
[15]   Graphene modified gold electrode via π-π stacking interaction for analysis of Cu2+ and Pb2+ [J].
Kong, Na ;
Liu, Jingquan ;
Kong, Qingshan ;
Wang, Rui ;
Barrow, Colin J. ;
Yang, Wenrong .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 :426-433
[16]   Processable aqueous dispersions of graphene nanosheets [J].
Li, Dan ;
Mueller, Marc B. ;
Gilje, Scott ;
Kaner, Richard B. ;
Wallace, Gordon G. .
NATURE NANOTECHNOLOGY, 2008, 3 (02) :101-105
[17]   Electrochemical behavior of acetaminophen and its detection on the PANI-MWCNTs composite modified electrode [J].
Li, Mingqi ;
Jing, Linhai .
ELECTROCHIMICA ACTA, 2007, 52 (09) :3250-3257
[18]   Polyaniline and poly(flavin adenine dinucleotide) doped multi-walled carbon nanotubes for p-acetamidophenol sensor [J].
Li, Ying ;
Umasankar, Yogeswaran ;
Chen, Shen-Ming .
TALANTA, 2009, 79 (02) :486-492
[19]  
Oliveira M.F., 2004, ANAL BIOANAL CHEM, V380, P135
[20]   Gold nanoparticle-based electrochemical biosensors [J].
Pingarron, Jose M. ;
Yanez-Sedeno, Paloma ;
Gonzalez-Cortes, Araceli .
ELECTROCHIMICA ACTA, 2008, 53 (19) :5848-5866