Fixation of Periprosthetic Femoral Shaft Fractures Adjacent to a Well-Fixed Femoral Stem With Reversed Distal Femoral Locking Plate

被引:32
作者
Ebraheim, Nabil A. [1 ]
Gomez, Carlos [1 ]
Ramineni, Satheesh K. [1 ]
Liu, Jiayong [1 ]
机构
[1] Univ Toledo, Med Ctr, Dept Orthopaed Surg, Toledo, OH 43614 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2009年 / 66卷 / 04期
关键词
Periprosthetic fracture; Femur; Locking plate; FEMUR FRACTURES; KNEE ARTHROPLASTY; HIP-ARTHROPLASTY; MANAGEMENT; IMPLANT; SYSTEM; CABLE; LISS;
D O I
10.1097/TA.0b013e318182561f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Numerous fixation methods have been described for the fixation of Vancouver type B1 periprosthetic fractures, but there have been a very few reports in the literature regarding the use of locking plates and their outcomes for this fracture. The objective of this study was to analyze clinically and radiographically, the results of fixation of Vancouver type B1 periprosthetic femoral fractures with a reversed distal femoral locking plate. Methods: Thirteen consecutive patients with Vancouver type B1 periprosthetic femoral fracture were stabilized with reversed distal femoral locking plate. Patients were followed up At 2, 6, 12, 24, and 48 weeks and yearly thereafter. They were assessed clinically and radiographically for union, delayed union, malunion, hardware failure, nonunion, infection, and stability of the femoral prosthesis. Results: The average duration of follow-up was 18 months. All fractures healed at an average of 14 weeks from fixation. Complications include superficial wound infection in one and flare-up of previous infection in one with union at 20 and 28 weeks, respectively. Twelve femoral prostheses were stable and all patients were ambulatory, with or without a walking aid at final follow-up. There was no hardware failure or nonunion. Conclusions: Reversed distal femoral locking plate treatment is a feasible and effective choice for stabilization with femoral stem retention after Vancouver type B1 periprosthetic femoral fracture in an elderly patient population.
引用
收藏
页码:1152 / 1157
页数:6
相关论文
共 25 条
[1]   Percutaneous plate fixation for periprosthetic femoral fractures - a preliminary report [J].
Abhaykumar, S ;
Elliott, DS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (08) :627-630
[2]   The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty [J].
Ahuja, S ;
Chatterji, S .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01) :47-50
[3]  
Beals RK, 1996, CLIN ORTHOP RELAT R, P238
[4]  
BERLUSCONI M, 2004, J ORTHOP TRAUMA S9, V18, pS1
[5]   Management of periprosthetic fractures - The hip [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :11-13
[6]   Locking compression plate fixation of Vancouver type-b1 periprosthetic femoral fractures [J].
Buttaro, M. A. ;
Farfalli, G. ;
Nunez, M. Paredes ;
Comba, F. ;
Piccaluga, F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :1964-1969
[7]  
DUNCAN CP, 1995, INSTR COURSE LECT, V44, P293
[8]   Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant [J].
Erhardt, J. B. ;
Grob, K. ;
Roderer, G. ;
Hoffmann, A. ;
Forster, T. N. ;
Kuster, M. S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) :409-416
[9]   Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems - A biomechanical comparison of locked plating and conventional cable plates [J].
Fulkerson, E ;
Koval, K ;
Preston, CF ;
Iesaka, K ;
Kummer, FJ ;
Egol, KA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (02) :89-93
[10]   Management of periprosthetic femur fractures with a first generation locking plate [J].
Fulkerson, Eric ;
Tejwani, Nirmal ;
Stuchin, Steven ;
Egol, Kenneth .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (08) :965-972