Application of Direct Virtual Coil to Dynamic Contrast-Enhanced MRI and MR Angiography with Data-Driven Parallel Imaging

被引:3
作者
Wang, Kang [1 ]
Beatty, Philip J. [2 ,3 ]
Nagle, Scott K. [4 ,5 ]
Reeder, Scott B. [4 ,5 ,6 ]
Holmes, James H. [1 ]
Rahimi, Mahdi S. [6 ]
Bell, Laura C. [4 ]
Korosec, Frank R. [4 ,5 ]
Brittain, Jean H. [1 ]
机构
[1] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
[2] Sunnybrook Res Inst, Toronto, ON, Canada
[3] GE Healthcare, Global Appl Sci Lab, Thornhill, ON, Canada
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
关键词
parallel imaging; magnetic resonance imaging; direct virtual coil; dynamic imaging; coil combination; channel compression; AUTO-SMASH; RECONSTRUCTION; COMPRESSION; PHASE; WATER; FAT; RESOLUTION; EFFICIENT; CHANNELS; ARRAYS;
D O I
10.1002/mrm.24686
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo demonstrate the feasibility of direct virtual coil (DVC) in the setting of 4D dynamic imaging used in multiple clinical applications. Theory and MethodsThree dynamic imaging applications were chosen: pulmonary perfusion, liver perfusion, and peripheral MR angiography (MRA), with 18, 11, and 10 subjects, respectively. After view-sharing, the k-space data were reconstructed twice: once with channel-by-channel (CBC) followed by sum-of-squares coil combination and once with DVC. Images reconstructed using CBC and DVC were compared and scored based on overall image quality by two experienced radiologists using a five-point scale. ResultsThe CBC and DVC showed similar image quality in image domain. Time course measurements also showed good agreement in the temporal domain. CBC and DVC images were scored as equivalent for all pulmonary perfusion cases, all liver perfusion cases, and four of the 10 peripheral MRA cases. For the remaining six peripheral MRA cases, DVC were scored as slightly better (not clinically significant) than the CBC images by Radiologist A and as equivalent by Radiologist B. ConclusionFor dynamic contrast-enhanced MR applications, it is clinically feasible to reduce image reconstruction time while maintaining image quality and time course measurement using the DVC technique. Magn Reson Med 71:783-789, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:783 / 789
页数:7
相关论文
共 28 条
[1]  
Beatty PJ., 2007, P 15 ANN M ISMRM
[2]  
Beatty PJ, 2009, P 17 ANN M ISMRM
[3]  
Beatty PJ, 2010, P 18 ANN M ISMRM
[4]  
Beatty PJ, 2008, P 16 ANN M ISMRM TOR
[5]   Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods [J].
Brau, Anja C. S. ;
Beatty, Philip J. ;
Skare, Stefan ;
Bammer, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :382-395
[6]   Array compression for MRI with large coil arrays [J].
Buehrer, Martin ;
Pruessmann, Klaas P. ;
Boesiger, Peter ;
Kozerke, Sebastian .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1131-1139
[7]   Contrast-Enhanced MR Angiography Using Time Resolved Interleaved Projection Sampling With Three-Dimensional Cartesian Phase and Slice Encoding (TRIPPS) [J].
Du, Jiang .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) :918-924
[8]   The SENSE ghost: Field-of-view restrictions for SENSE imaging [J].
Goldfarb, JW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) :1046-1051
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   Field-of-view limitations in parallel imaging [J].
Griswold, MA ;
Kannengiesser, S ;
Heidemann, RM ;
Wang, JM ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1118-1126