Measurement of neutron fluence spectra up to 150 MeV using a stacked scintillator neutron spectrometer

被引:6
|
作者
Brooks, FD [1 ]
Allie, MS
Buffler, A
Dangendorf, V
Herbert, MS
Makupula, SA
Nolte, R
Smit, FD
机构
[1] Univ Cape Town, Dept Phys, ZA-7700 Rondebosch, South Africa
[2] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[3] IThemba Lab Accelerator Based Sci, ZA-7129 Somerset W, South Africa
关键词
D O I
10.1093/rpd/nch213
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A stacked scintillator neutron spectrometer (S3N) consisting of three slabs of liquid organic scintillator is described. A pulsed beam providing a broad spectrum of neutron energies is used to determine the detection efficiency of the spectrometer as a function of incident neutron energy and to measure the pulse height response matrix of the system. Neutron spectra can then be determined for beams with any kind of time structure by unfolding pulse height spectra measured by the S3N. Examples of fluence spectrum measurements in the energy range 20-150 MeV are presented.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 50 条
  • [1] Measurement of neutron energy spectra from 15 to 150 MeV using stacked liquid scintillators
    Buffler, A
    Brooks, FD
    Allie, MS
    Binns, PJ
    Dangendorf, V
    Langen, KM
    Nolte, R
    Schuhmacher, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 181 - 185
  • [2] ABSOLUTE MEASUREMENT OF 14.57 MeV NEUTRON FLUENCE RATE USING PROTON RECOIL NEUTRON TELESCOPE
    Ghodke, Shobha
    Sathian, V.
    Singh, Yashoda
    Patel, Tarun
    Santra, S.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (03) : 307 - 319
  • [3] ORGANIC SCINTILLATOR AS A 10-30 MEV NEUTRON SPECTROMETER
    LEWIS, CW
    BLAIR, JM
    NUCLEAR INSTRUMENTS & METHODS, 1965, 35 (02): : 261 - &
  • [4] Measurement and simulation of neutron beam fluence spectra
    Herbert, M.
    Nchodu, R.
    Maleka, P.
    PROCEEDINGS OF SAIP2012: THE 57TH ANNUAL CONFERENCE OF THE SOUTH AFRICAN INSTITUTE OF PHYSICS, 2012, : 494 - 498
  • [5] Neutron fluence measurements with a liquid scintillator
    Binns, PJ
    Hough, JH
    Simpson, BRS
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 247 - 250
  • [6] Design of a Compact Neutron Spectrometer Using the CLYC Scintillator
    Wang, Qibiao
    Yang, Yigang
    Tuo, Xiguo
    Deng, Chao
    Li, Huailiang
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [7] Measurement of response functions of organic liquid scintillator for neutron energy range up to 390 MeV
    Taniguchi, S.
    Nakao, N.
    Yamakawa, H.
    Oishi, K.
    Nakamura, T.
    Tamii, A.
    Hatanaka, K.
    Saito, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02): : 954 - 957
  • [8] Measuring neutron spectra in radiotherapy using the nested neutron spectrometer
    Maglieri, Robert
    Licea, Angel
    Evans, Michael
    Seuntjens, Jan
    Kildea, John
    MEDICAL PHYSICS, 2015, 42 (11) : 6162 - 6169
  • [9] PLOTTING NEUTRON FLUENCE SPECTRA
    ROHRIG, N
    HEALTH PHYSICS, 1983, 45 (03): : 817 - 818
  • [10] Measurement of neutron spectra in the AWE workplace using a Bonner sphere spectrometer
    Danyluk, Peter
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (04) : 699 - 715