Conditions to minimize soft single biomolecule imaging with atomic force microscopy

被引:12
|
作者
Godon, Christian [1 ]
Teulon, Jean-Marie [2 ,3 ,4 ]
Odorico, Michael [5 ]
Basset, Christian [6 ]
Meillan, Matthieu [7 ,8 ]
Vellutini, Luc [7 ,8 ]
Chen, Shu-wen W. [9 ]
Pellequer, Jean-Luc [2 ,3 ,4 ]
机构
[1] CEA, BIAM, F-13108 St Paul Les Durance, France
[2] Univ Grenoble Alpes, IBS, F-38044 Grenoble, France
[3] CNRS, IBS, F-38044 Grenoble, France
[4] CEA, IBS, F-38044 Grenoble, France
[5] CEA CNRS UM2 ENSCM, ICSM UMR5257, F-30207 Bagnols Sur Ceze, France
[6] CEA, BIG, F-38054 Grenoble, France
[7] Univ Bordeaux, ISM, UMR 5255, F-33400 Talence, France
[8] CNRS, ISM, UMR 5255, F-33400 Talence, France
[9] 478 Rue Cyprien Jullin, F-38470 Vinay, France
关键词
AFM topography; Single molecule deformation; Mica; Self-assembled monolayers; Peakforce tapping; Tobacco mosaic virus; TOBACCO-MOSAIC-VIRUS; RAY FIBER DIFFRACTION; HIGH-RESOLUTION; AFM TOPOGRAPHS; SURFACE; RECONSTRUCTION; PROTEINS; MOLECULE; MICA; MACROMOLECULES;
D O I
10.1016/j.jsb.2016.12.011
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A recurrent interrogation when imaging soft biomolecules using atomic force microscopy (AFM) is the putative deformation of molecules leading to a bias in recording true topographical surfaces. Deformation of biomolecules comes from three sources: sample instability, adsorption to the imaging substrate, and crushing under tip pressure. To disentangle these causes, we measured the maximum height of a well-known biomolecule, the tobacco mosaic virus (TMV), under eight different experimental conditions positing that the maximum height value is a specific indicator of sample deformations. Six basic AFM experimental factors were tested: imaging in air (AIR) versus in liquid (LIQ), imaging with flat minerals (MICA) versus flat organic surfaces (self-assembled monolayers, SAM), and imaging forces with oscillating tapping mode (TAP) versus PeakForce tapping (PFT). The results show that the most critical parameter in accurately measuring the height of TMV in air is the substrate. In a liquid environment, regardless of the substrate, the most critical parameter is the imaging mode. Most importantly, the expected TMV height values were obtained with both imaging with the PeakForce tapping mode either in liquid or in air at the condition of using self-assembled monolayers as substrate. This study unambiguously explains previous poor results of imaging biomolecules on mica in air and suggests alternative methodologies for depositing soft biomolecules on well organized self-assembled monolayers. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 50 条
  • [21] Atomic Force Microscopy Imaging of Crystalline Sucrose in Alcohols
    Teduka, Yuya
    Sasahara, Akira
    Onishi, Hiroshi
    ACS OMEGA, 2020, 5 (06): : 2569 - 2574
  • [22] Atomic force microscopy in mechanical measurements of single nanowires
    Pruchnik, Bartosz C.
    Fidelus, Janusz D.
    Gacka, Ewelina
    Mika, Krystyna
    Zaraska, Leszek
    Sulka, Grzegorz D.
    Gotszalk, Teodor P.
    ULTRAMICROSCOPY, 2024, 263
  • [23] Atomic Force Microscopy (AFM) study of redox conditions in sandstones: Impact on wettability modification and mineral morphology
    Yesufu-Rufai, Sherifat
    Marcelis, Fons
    Georgiadis, Apostolos
    Berg, Steffen
    Rucker, Maja
    van Wunnik, Johannes
    Luckham, Paul
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2020, 597
  • [24] Imaging DNA molecules on mica surface by atomic force microscopy in air and in liquid
    Liu, ZG
    Li, Z
    Zhou, HL
    Wei, G
    Song, YH
    Wang, L
    MICROSCOPY RESEARCH AND TECHNIQUE, 2005, 66 (04) : 179 - 185
  • [25] Theoretical simulation of noncontact atomic force microscopy in liquids
    Tsukada, M.
    Watanabe, N.
    Harada, M.
    Tagami, K.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (03):
  • [26] Visualizing water molecule distribution by atomic force microscopy
    Kimura, Kenjiro
    Ido, Shinichiro
    Oyabu, Noriaki
    Kobayashi, Kei
    Hirata, Yoshiki
    Imai, Takashi
    Yamada, Hirofumi
    JOURNAL OF CHEMICAL PHYSICS, 2010, 132 (19)
  • [27] Imaging of Xenopus laevis Oocyte Plasma Membrane in Physiological-Like Conditions by Atomic Force Microscopy
    Santacroce, Massimo
    Daniele, Federica
    Cremona, Andrea
    Scaccabarozzi, Diletta
    Castagna, Michela
    Orsini, Francesco
    MICROSCOPY AND MICROANALYSIS, 2013, 19 (05) : 1358 - 1363
  • [28] Soft-contact imaging in liquid with frequency-modulation torsion resonance mode atomic force microscopy
    Yang, Chih-Wen
    Hwang, Ing-Shouh
    NANOTECHNOLOGY, 2010, 21 (06)
  • [29] Simultaneous Atomic Imaging of Atomic Force Microscopy and Scanning Tunneling Microscopy Using Metal Coated Cantilevers
    Sawada, Daisuke
    Hirai, Akira
    Sugimoto, Yoshiaki
    Abe, Masayuki
    Morita, Seizo
    MATERIALS TRANSACTIONS, 2009, 50 (05) : 940 - 942
  • [30] Comparison of Scanning Ion Conductance Microscopy with Atomic Force Microscopy for Cell Imaging
    Rheinlaender, Johannes
    Geisse, Nicholas A.
    Proksch, Roger
    Schaeffer, Tilman E.
    LANGMUIR, 2011, 27 (02) : 697 - 704