Remote magnetic navigation versus manual control navigation for atrial fibrillation ablation: A systematic review and meta-analysis

被引:14
作者
Jia, Kangni [1 ]
Jin, Qi [1 ]
Liu, Ao [1 ]
Wu, Liqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Ruijin Hosp, Dept Cardiol, Sch Med, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Atrial fibrillation; Catheter ablation; Remote magnetic navigation; Meta-analysis; LONG-TERM OUTCOMES; CATHETER ABLATION; CONVENTIONAL ABLATION; GUIDED ABLATION; SAFETY; EFFICACY; FLUOROSCOPY; CONSENSUS;
D O I
10.1016/j.jelectrocard.2019.05.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this review was to evaluate the efficacy and safety between remote magnetic navigation (RMN) and manual control navigation (MCN) for atrial fibrillation (AF) ablation. Methods: We searched the PubMed, EMBASE and Cochrane library databases using the key words AF, ablation and magnetic navigation. Results: Eighteen studies were identified in this analysis including 4046 patients comparing RMN and MCN in AF ablation, which were all non-randomized controlled studies. No significant difference of AF recurrence rate (40% vs. 38%, OR 1.00, 95% CI 0.82-1.22, p = 0.97) and acute success rate in achieving pulmonary vein isolation (91% vs. 93%, OR 0.44, 95% CI 0.16-1.17, p = 0.10) was found between RMN and MCN. However, compared with MCN, RMN was associated with significantly lower complication rate (2% vs. 5%, OR 0.44, 95% CI 0.28-0.69,p = 0.0003) and shorter fluoroscopy time (MD -9.71 min, 95% CI -15.80 to -3.63, p = 0.002). Procedure time (MD 47.05 min, 95% CI 27.5-66.58, p < 0.00001) and ablation time (MD 15.90 min, 95% CI 9.62-22.18, p < 0.00001) of RMN guided AF ablation were significantly longer than those of MCN. Conclusion: The results of this study suggest that RMN is as effective as MCN in achieving pulmonary vein isolation and freedom from AF recurrence, and has superior safety with less complications and shorter fluoroscopy time. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:78 / 86
页数:9
相关论文
共 34 条
[11]   Contact force with magnetic-guided catheter ablation [J].
Bessiere, Francis ;
Zikry, Christopher ;
Rivard, Lena ;
Dyrda, Katia ;
Khairy, Paul .
EUROPACE, 2018, 20 :1-4
[12]   Catheter Ablation Utilizing Remote Magnetic Navigation: A Review of Applications and Outcomes [J].
Bradfield, Jason ;
Tung, Roderick ;
Mandapati, Ravi ;
Boyle, Noel G. ;
Shivkumar, Kalyanam .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (08) :1021-1034
[13]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[14]   Comparison of Magnetic Navigation System and Conventional Method in Catheter Ablation of Atrial Fibrillation: Is Magnetic Navigation System Is More Effective and Safer Than Conventional Method? [J].
Choi, Min Seok ;
Oh, Yong-Seog ;
Jang, Sung Won ;
Kim, Ji Hoon ;
Shin, Woo Seung ;
Youn, Ho-Joong ;
Jung, Wook Sung ;
Lee, Man Young ;
Seong, Ki Bae .
KOREAN CIRCULATION JOURNAL, 2011, 41 (05) :248-252
[15]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[16]   GRADE:: an emerging consensus on rating quality of evidence and strength of recommendations [J].
Guyatt, Gordon H. ;
Oxman, Andrew D. ;
Vist, Gunn E. ;
Kunz, Regina ;
Falck-Ytter, Yngve ;
Alonso-Coello, Pablo ;
Schuenemann, Holger J. .
BRITISH MEDICAL JOURNAL, 2008, 336 (7650) :924-926
[17]   Challenges in systematic reviews of therapeutic devices and procedures [J].
Hartling, L ;
McAlister, FA ;
Rowe, BH ;
Ezekowitz, J ;
Friesen, C ;
Klassen, TP .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (12) :1100-1111
[18]   Efficacy and Safety of Atrial Fibrillation Ablation Using Remote Magnetic Navigation: Experience from 1,006 Procedures [J].
Jin, Qi ;
Pehrson, Steen ;
Jacobsen, Peter Karl ;
Chen, Xu .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 :S23-S28
[19]   Feasibility and Safety of Remote-Controlled Magnetic Navigation for Ablation of Atrial Fibrillation [J].
Katsiyiannis, William T. ;
Melby, Daniel P. ;
Matelski, Jayme L. ;
Ervin, Vanessa L. ;
Laverence, Kerri L. ;
Gornick, Charles C. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (12) :1674-1676
[20]   Impact of Remote Magnetic Catheter Navigation on Ablation Fluoroscopy and Procedure Time [J].
Kim, Albert M. ;
Turakhia, Mintu ;
Lu, Jonathan ;
Badhwar, Nitish ;
Lee, Byron K. ;
Lee, Randall J. ;
Marcus, Gregory M. ;
Tseng, Zian H. ;
Scheinman, Melvin ;
Olgin, Jeffrey E. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (11) :1399-1404