Flow-injection chemiluminescence determination of fluoroquinolones

被引:47
作者
Rao, Y
Tong, Y
Zhang, XR [1 ]
Luo, GA
Baeyens, WRG
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] State Univ Ghent, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
ofloxacin; norfloxacin; ciprofloxacin; lomefloxacin; chemiluminescence; flow-injection; cerium (IV);
D O I
10.1080/00032710008543113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-injection CL method was developed for the determination of fluoroquinolones including ofloxacin, norfloxacin, ciprofloxacin and lomefloxacin in pharmaceutical preparations, based on the chemiluminescence reaction of sulphite with cerium(IV) sensitized by these compounds. The linear ranges are 0.04 to 4.0 mu g ml(-1) for ofloxacin and 0.4 to 40.0 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The detection limits are 0.016 mu g ml(-1) for ofloxacin and 0.16 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The relative standard deviations (RSD) are 2.1 to 2.6% (n = 10) for these fluoroquinolones. The analytical procedure has been applied to the determination of the fluoroquinolones in pharmaceutical commercial formulations. The results are in agreement with those obtained by the official methods.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 50 条
[31]   Flow-injection with enhanced chemiluminescence detection of ofloxacin in human plasma [J].
Zhang, XH ;
Jin, OY ;
Zhai, S ;
Huang, GM ;
Zha, HC .
LUMINESCENCE, 2005, 20 (4-5) :362-369
[32]   Sensitive Determination of Bovine Serum Albumin by Flow-Injection Chemiluminescence [J].
Du Jun-jun ;
Wang Hui ;
Ren Shu-wei ;
Zhou Min ;
Liu Ying-ying ;
Liu Yan-ming .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (06) :1693-1696
[33]   Flow-injection chemiluminescence determination of melamine in urine and plasma [J].
Tang, Xiaoshuang ;
Shi, Xiyan ;
Tang, Yuhai ;
Yue, Zhongjin ;
He, Qiqi .
LUMINESCENCE, 2012, 27 (03) :229-233
[34]   Determination of phenol in water by flow-injection chemiluminescence analysis [J].
Gong, ZJ ;
Huang, YM ;
Zhang, ZJ .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) :1123-1125
[35]   Chemiluminescence determination of thioridazine hydrochloride by flow-injection analysis [J].
Kojlo, A ;
Michalowski, J ;
Wolyniec, E .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) :85-91
[36]   Flow-Injection Chemiluminescence Determination of Cobalt(II) with Umbelliferon [J].
Watanabe, Kunihiro ;
Onishi, Haruka ;
Shitanda, Isao ;
Itagaki, Masayuki .
BUNSEKI KAGAKU, 2009, 58 (06) :531-537
[37]   Flow-injection chemiluminescence method for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride [J].
Wang, Nan-Nan ;
Sha, Yan-Qing ;
Tang, Yu-Hai ;
Yin, He-Ping ;
Wu, Xiao-Zhong .
LUMINESCENCE, 2009, 24 (03) :178-182
[38]   Flow-injection chemiluminescence determination of urea by oxidation with N-bromosuccinimide [J].
Li, BX ;
Zhang, ZJ ;
Jin, Y .
ANALYTICAL LETTERS, 2001, 34 (12) :2141-2151
[39]   Flow-injection chemiluminescence determination of gentamicin: optimization by central composite design [J].
Iranifam, M. ;
Hasanzadeh, A. ;
Fathinia, M. ;
Khataee, A. R. ;
Mousavi, S. A. .
LUMINESCENCE, 2014, 29 (03) :230-238
[40]   Flow-injection determination of vitamin K3 by a chemiluminescence sensor [J].
Huang, YM ;
Chen, ZQ ;
Zhang, ZJ .
ANALYTICAL SCIENCES, 1999, 15 (12) :1227-1230