Flow-injection chemiluminescence determination of fluoroquinolones

被引:47
|
作者
Rao, Y
Tong, Y
Zhang, XR [1 ]
Luo, GA
Baeyens, WRG
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] State Univ Ghent, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
ofloxacin; norfloxacin; ciprofloxacin; lomefloxacin; chemiluminescence; flow-injection; cerium (IV);
D O I
10.1080/00032710008543113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-injection CL method was developed for the determination of fluoroquinolones including ofloxacin, norfloxacin, ciprofloxacin and lomefloxacin in pharmaceutical preparations, based on the chemiluminescence reaction of sulphite with cerium(IV) sensitized by these compounds. The linear ranges are 0.04 to 4.0 mu g ml(-1) for ofloxacin and 0.4 to 40.0 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The detection limits are 0.016 mu g ml(-1) for ofloxacin and 0.16 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The relative standard deviations (RSD) are 2.1 to 2.6% (n = 10) for these fluoroquinolones. The analytical procedure has been applied to the determination of the fluoroquinolones in pharmaceutical commercial formulations. The results are in agreement with those obtained by the official methods.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 50 条
  • [11] DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
    唐玉海
    韩小年
    于春玲
    孙媛媛
    姚宏
    Academic Journal of Xi'an Jiaotong University, 2006, (02) : 136 - 138
  • [12] A novel flow-injection chemiluminescence system for the determination of guanine
    Yang, M
    Liu, R
    Hou, DY
    Guo, YY
    LUMINESCENCE, 2005, 20 (4-5) : 307 - 310
  • [13] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF THE HYDRAZONES OF AROMATIC KETONES
    AHMED, TEA
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1994, 292 (1-2) : 169 - 174
  • [14] Determination of Three Imidazole Derivatives by Flow-Injection Chemiluminescence
    Sun, Sijuan
    Tang, Yuhai
    Fu, Qiang
    Chen, Jine
    Zhang, Guangbin
    ANALYTICAL LETTERS, 2009, 42 (12) : 1868 - 1881
  • [15] Chemiluminescence determination of ultramicro DNA with a flow-injection method
    Chen, H
    Zhou, M
    Jin, XY
    Song, YM
    Zhang, ZY
    Ma, YJ
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 31 - 36
  • [16] Flow-injection chemiluminescence method for the determination of hydrocortisone and progesterone
    Li, HN
    Ci, YX
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1484 - 1487
  • [17] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905
  • [18] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [19] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [20] Selective determination of human immunoglobulin G by flow-injection chemiluminescence
    Zhou, Min
    Wang, Jiuchun
    Ma, Yongjun
    Fang, Yanjun
    Chen, Junhui
    Chen, Hui
    LUMINESCENCE, 2011, 26 (02) : 142 - 147