Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads

被引:66
作者
Esposito, M
Kennergren, C
Holmström, N
Nilsson, S
Eckerdal, J
Thomsen, P
机构
[1] Univ Gothenburg, Dept Biomat, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
[2] Univ Gothenburg, Dept Cardiothorac Surg, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
[3] St Jude Med AB, Jarfalla, Sweden
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 63卷 / 05期
关键词
endothelium; fibrinogen; immunohistochemistry; laser extraction; pacemakers;
D O I
10.1002/jbm.10306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Immunohistochemical and morphologic techniques were employed to evaluate the tissue response around chronically implanted pacing leads. Seventeen leads were retrieved from 12 patients. Leads were extracted by direct manual traction (1), extraction with sheaths and locking stylets (1), or with by a combination of mechanical tools and Excimer laser sheaths (15). Mean lead implantation time was 5.6 years (range 1-8 years). Frozen sections, 6-8 mum thick, were incubated with antibodies against HLA-DR antigen, endothelial cells, macrophages, T cells, plasma cells, fibrinogen, and interleukin-1beta. Prominent morphologic observations were fibrous encapsulations of the leads. Immunohistochemical analysis revealed a tissue generally devoid of inflammatory and immune cells. The fibrous capsule surrounding the lead was partially or completely covered with a monolayer of CD34 expressing endothelial cells. The results from this study provide useful information in design and material selection for pacemaker leads. Endothelialization of the fibrous encapsulation indicates a functionalization of blood-contacting surfaces around pacemaker materials, thus providing a mechanism for long-term persistence of foreign materials in the blood. The laser method allowed an efficient extraction of pacemaker leads without damage to the studied tissues, as suggested by the presence of immunolabeled cells close to the cut surfaces. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:548 / 558
页数:11
相关论文
共 23 条
  • [1] POROUS ENDOCARDIAL ELECTRODE
    AMUNDSON, DC
    MCARTHUR, W
    MOSHARRAFA, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (01): : 40 - 50
  • [2] STUDIES OF THE TISSUE REACTION INDUCED BY TRANSVENOUS PACEMAKER ELECTRODES .1. MICROSCOPIC EXAMINATION OF THE EXTENT OF CONNECTIVE-TISSUE AROUND THE ELECTRODE TIP IN THE HUMAN RIGHT VENTRICLE
    BEYERSDORF, F
    SCHNEIDER, M
    KREUZER, J
    FALK, S
    ZEGELMAN, M
    SATTER, P
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1753 - 1759
  • [3] COMPARISON OF A POROUS-SURFACED WITH A TOTALLY POROUS VENTRICULAR ENDOCARDIAL PACING ELECTRODE
    BOBYN, JD
    WILSON, GJ
    MYCYK, TR
    KLEMENT, P
    TAIT, GA
    PILLIAR, RM
    MACGREGOR, DC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (04): : 405 - 416
  • [4] Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996
    Byrd, CL
    Wilkoff, BL
    Love, CJ
    Sellers, TD
    Turk, KT
    Reeves, R
    Young, R
    Crevey, B
    Kutalek, SP
    Freedman, R
    Friedman, R
    Trantham, J
    Watts, M
    Schutzman, J
    Oren, J
    Wilson, J
    Gold, F
    Fearnot, NE
    Van Zandt, HJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09): : 1348 - 1357
  • [5] Camerini F, 1971, G Ital Cardiol, V1, P409
  • [6] Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    Candinas, R
    Duru, F
    Schneider, J
    Lüscher, TF
    Stokes, K
    [J]. MAYO CLINIC PROCEEDINGS, 1999, 74 (02) : 120 - 125
  • [7] MORPHOLOGICAL-CHANGES IN HUMAN MYOCARDIUM DURING PERMANENT PACING
    CHATELAIN, P
    ADAMEC, R
    COX, JN
    [J]. VIRCHOWS ARCHIV A-PATHOLOGICAL ANATOMY AND HISTOPATHOLOGY, 1985, 407 (01) : 43 - 57
  • [8] Antibiotic prophylaxis for permanent pacemaker implantation - A meta-analysis
    Da Costa, A
    Kirkorian, G
    Cucherat, M
    Delahaye, F
    Chevalier, P
    Cerisier, A
    Isaaz, K
    Touboul, P
    [J]. CIRCULATION, 1998, 97 (18) : 1796 - 1801
  • [9] A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE
    DONATH, K
    BREUNER, G
    [J]. JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) : 318 - 326
  • [10] CARDIAC PATHOLOGY OF TRANSVENOUS PACEMAKERS IN DOGS
    FISHBEIN, MC
    TAN, KS
    BEAZELL, JW
    SCHULMAN, JH
    HIROSE, FM
    CRILEY, JM
    [J]. AMERICAN HEART JOURNAL, 1977, 93 (01) : 73 - 81