Development of PDMS-based flexible dry type SEMG electrodes by micromachining technologies

被引:12
|
作者
Jung, Jung Mo [1 ]
Cha, Doo Yeol [1 ]
Kim, Deok Su [1 ]
Yang, Hee Jun [1 ]
Choi, Kyo Sang [1 ]
Choi, Jong Myoung [1 ]
Chang, Sung Pil [1 ]
机构
[1] Inha Univ, Dept Elect Engn, Inchon 402751, South Korea
来源
关键词
CONTROLLED PROSTHETIC HAND; MUSCLE-ACTIVITY; EMG; SIGNALS; SYSTEM; ROBOT;
D O I
10.1007/s00339-014-8244-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors developed PDMS (polydimethylsiloxane)-based dry type surface electromyography (SEMG) electrodes for myoelectric prosthetic hands. The SEMG electrodes were strongly recommended to be fabricated on a flexible substrate to be compatible with the surface of skin. In this study, the authors designed a bar-shaped dry-type flexible SEMG electrodes comprised of two input electrodes and a reference electrode on a flexible PDMS substrate to measure EMG signals. The space distance between each electrode with a size of 10 mm 9 2 mm was chosen to 18 mm to get optimal result according to the simulation result with taking into consideration the conduction velocity and the median frequency of EMG signals. Raw EMG signals were measured from Brachioradialis, Biceps brachii, deltoideus, and pectoralis major muscles, to drive the application of the myoelectric hand prosthesis. Measured raw EMG signals were transformed to root mean square (RMS) EMG signals using Acqknowledge4.2. The experimental peak voltage values of RMS EMG signals from Brachioradialis, Biceps brachii, deltoideus, and pectoralis major muscles were 2.96 V, 4.45 V, 1.74 V, and 2.62 V, respectively. Values from the dry type flexible SEMG electrodes showed higher peak values than a commercially available wet type Ag-AgCl electrode. The study shows that the PDMS-based flexible electrode devised for measuring myoelectric signals from the surface of skin is more useful for prosthetic hands because of its greater sensitivity and flexibility.
引用
收藏
页码:1395 / 1401
页数:7
相关论文
共 50 条
  • [41] Study of PDMS-based flexible conductive elastomeric composite filled with rGO-CaCO3 nanocomposite
    Mandal, Swaroop Kumar
    Kumar, Deepak
    POLYMER-PLASTICS TECHNOLOGY AND MATERIALS, 2023, 62 (13): : 1776 - 1788
  • [42] Flexible and Stretchable Dry Active Electrodes With PDMS and Silver Flakes for Bio-Potentials Sensing Systems
    Jiang, Yizhou
    Liu, Lili
    Chen, Lin
    Zhang, Yuanyuan
    He, Zishang
    Zhang, Wei
    Zhao, Jun
    Lu, Danzhu
    He, Jie
    Zhu, Hongda
    Gong, Ye
    Zheng, Li-Rong
    Wang, Yuanyuan
    Li, Zhuo
    Qin, Yajie
    IEEE SENSORS JOURNAL, 2021, 21 (10) : 12255 - 12268
  • [43] Non-invasive and Flexible Electrodes Based on Multimaterial Fiber for sEMG Signal Detection
    Fall, C. L.
    Roudjane, M.
    Ghafouri, S.
    Mascret, Q.
    Bielmann, M.
    Tam, S.
    Roy, J. -S.
    Bouyer, L.
    Gosselin, B.
    Messaddeq, Y.
    2018 IEEE LIFE SCIENCES CONFERENCE (LSC), 2018, : 179 - 182
  • [44] PDMS-Based Microfluidic Glucose Biofuel Cell Integrated With Optimized Laser-Induced Flexible Graphene Bioelectrodes
    Rewatkar, Prakash
    Kothuru, Avinash
    Goel, Sanket
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67 (04) : 1832 - 1838
  • [45] A Fabrication Method of Out-of-Plane Stretchable and Flexible Electrodes Based on PDMS
    Chou, Namsun
    Kim, Sohee
    MICRO/NANO MATERIALS, DEVICES, AND SYSTEMS, 2013, 8923
  • [46] Development of a PDMS-based microchip electrophoresis device for continuous online in vivo monitoring of microdialysis samples
    Nandi, Pradyot
    Desaias, Dhara P.
    Lunte, Susan M.
    ELECTROPHORESIS, 2010, 31 (08) : 1414 - 1422
  • [47] Graphene-based flexible dry electrodes for biosignal detection
    Ali, Babar
    Bidsorkhi, Hossein C.
    D'Aloia, Alessandro G.
    Laracca, Marco
    Sarto, Maria S.
    2022 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS (IEEE FLEPS 2022), 2022,
  • [48] PDMS-based flexible and conductive composite films containing modified PEDOT:PSS coated channels as a potential neural conduit
    Buyukuysal, Orhan Gokalp
    Kilic, Busra
    Karaaslan, Cagatay
    Gokcen, Dincer
    Bayram, Cem
    Aydin, Halil Murat
    MATERIALS ADVANCES, 2025, 6 (05): : 1647 - 1666
  • [49] MWCNT-COOH/PDMS based dry ECG electrodes for ambulatory ECG recordings
    Gandhi, Bani
    Raghava, N. S.
    MATERIALS LETTERS, 2022, 307
  • [50] An ECG Acquisition System Prototype Design With Flexible PDMS Dry Electrodes and Variable Transform Length DCT-IV Based Compression Algorithm
    Luo, Ching-Hsing
    Ma, Wei-Jhe
    Juang, Wen-Ho
    Kuo, Shin-Hung
    Chen, Chih-Yuan
    Tai, Pei-Chen
    Lai, Shin-Chi
    IEEE SENSORS JOURNAL, 2016, 16 (23) : 8244 - 8254