Development of PDMS-based flexible dry type SEMG electrodes by micromachining technologies

被引:12
|
作者
Jung, Jung Mo [1 ]
Cha, Doo Yeol [1 ]
Kim, Deok Su [1 ]
Yang, Hee Jun [1 ]
Choi, Kyo Sang [1 ]
Choi, Jong Myoung [1 ]
Chang, Sung Pil [1 ]
机构
[1] Inha Univ, Dept Elect Engn, Inchon 402751, South Korea
来源
关键词
CONTROLLED PROSTHETIC HAND; MUSCLE-ACTIVITY; EMG; SIGNALS; SYSTEM; ROBOT;
D O I
10.1007/s00339-014-8244-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors developed PDMS (polydimethylsiloxane)-based dry type surface electromyography (SEMG) electrodes for myoelectric prosthetic hands. The SEMG electrodes were strongly recommended to be fabricated on a flexible substrate to be compatible with the surface of skin. In this study, the authors designed a bar-shaped dry-type flexible SEMG electrodes comprised of two input electrodes and a reference electrode on a flexible PDMS substrate to measure EMG signals. The space distance between each electrode with a size of 10 mm 9 2 mm was chosen to 18 mm to get optimal result according to the simulation result with taking into consideration the conduction velocity and the median frequency of EMG signals. Raw EMG signals were measured from Brachioradialis, Biceps brachii, deltoideus, and pectoralis major muscles, to drive the application of the myoelectric hand prosthesis. Measured raw EMG signals were transformed to root mean square (RMS) EMG signals using Acqknowledge4.2. The experimental peak voltage values of RMS EMG signals from Brachioradialis, Biceps brachii, deltoideus, and pectoralis major muscles were 2.96 V, 4.45 V, 1.74 V, and 2.62 V, respectively. Values from the dry type flexible SEMG electrodes showed higher peak values than a commercially available wet type Ag-AgCl electrode. The study shows that the PDMS-based flexible electrode devised for measuring myoelectric signals from the surface of skin is more useful for prosthetic hands because of its greater sensitivity and flexibility.
引用
收藏
页码:1395 / 1401
页数:7
相关论文
共 50 条
  • [31] Transparent and flexible AuNSs/PDMS-based SERS substrates for in-situ detection of pesticide residues
    Ma, Xiaoyuan
    Xie, Jie
    Wang, Zhouping
    Zhang, Yin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 267
  • [32] Multi-walled Carbon Nanotube (MWCNT)/PDMS-based Flexible Sensor for Medical Applications
    Park, Kihan
    Tran, Phillip
    Deaton, Nancy
    Desai, Jaydev P.
    2019 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS (ISMR), 2019,
  • [33] Flexible PDMS-based triboelectric nanogenerator for instantaneous force sensing and human joint movement monitoring
    Yu, Junbin
    Hou, Xiaojuan
    Cui, Min
    Shi, Shuzheng
    He, Jian
    Sun, Yawei
    Wang, Chao
    Chou, Xiujian
    SCIENCE CHINA-MATERIALS, 2019, 62 (10) : 1423 - 1432
  • [34] Development and characterization of a PDMS-based masking method for microfabricated Oral drug delivery devices
    Khorshid Kamguyan
    Lasse Højlund Eklund Thamdrup
    Lukas Vaut
    Line Hagner Nielsen
    Kinga Zor
    Anja Boisen
    Biomedical Microdevices, 2020, 22
  • [35] Studies on flexible strain sensor based on AgNWs-PDMS electrodes
    Zhang, Xiao
    Ma, Yanqing
    Ma, Lei
    ICEPT2019: THE 2019 20TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY, 2019,
  • [36] Flexible Pressure Sensor with Ag Wrinkled Electrodes Based on PDMS Substrate
    Cui, Jianli
    Zhang, Binzhen
    Duan, Junping
    Guo, Hao
    Tang, Jun
    SENSORS, 2016, 16 (12):
  • [37] Development and characterization of a PDMS-based masking method for microfabricated Oral drug delivery devices
    Kamguyan, Khorshid
    Thamdrup, Lasse Hojlund Eklund
    Vaut, Lukas
    Nielsen, Line Hagner
    Zor, Kinga
    Boisen, Anja
    BIOMEDICAL MICRODEVICES, 2020, 22 (02)
  • [38] PDMS-based, magnetically actuated variable optical attenuators obtained by soft lithography and inkjet printing technologies
    de Pedro, S.
    Cadarso, V. J.
    Munoz-Berbel, X.
    Plaza, J. A.
    Sort, J.
    Brugger, J.
    Buettgenbach, S.
    Llobera, A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 215 : 30 - 35
  • [39] Assembly and Simple Demonstration of a Micropump Installing PDMS-Based Thin Membranes as Flexible Micro Check Valves
    Tanaka, Yo
    Sato, Kae
    Kitamori, Takehiko
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2009, 5 (05) : 516 - 520
  • [40] Flexible Lead-Free BiFeO3/PDMS-Based Nanogenerator as Piezoelectric Energy Harvester
    Ren, Xiaohu
    Fan, Huiqing
    Zhao, Yuwei
    Liu, Zhiyong
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (39) : 26190 - 26197