Optimization of derivative kernels for exact cone-beam ROI reconstruction in spiral computed tomography

被引:0
作者
Lauritsch, G [1 ]
Sourbelle, K
Tam, KC
机构
[1] Seimens Med Solut, D-91050 Erlangen, Germany
[2] Univ Erlangen Nurnberg, IMP, D-91054 Erlangen, Germany
[3] Siemens Corp Res Inc, Princeton, NJ 08540 USA
关键词
cone-beam computed tomography (CT); cone-beam filtered backprojection (FBP); algorithms; filter design; finite differences; linogram; local region-of-interest (ROI) algorithm; numerical derivative; ringing artifacts; spiral CT; three-dimensional (3-D) radon inversion; windowed filter kernels;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A recent comparison study showed that exact filtered backprojection (FBP)-based solutions of the long object problem are numerically stable and that their image quality is mostly affected by filter design. In this paper, the impact of the kernel design on image. quality is demonstrated systematically in the case of the local region-of-interest (ROI) algorithm. First of all, the implementation is improved by the use of the Linogram technique to eliminate interpolations in the filter step and to speed up computation. In the case of the local ROI method, favorable kernels for one-dimensional (1-D) partial derivatives have to be designed. Finite differences are fast to compute but cause ringing artifacts. More sophisticated kernels can be designed in a straightforward manner in Fourier space, identifying the window function most appropriate to a given application. No ringing artifacts are observed for the windowed kernels under investigation. In addition, windowed kernels are superior to the finite differences regarding the spatial resolution versus noise properties. For partial derivatives in directions with data truncation the projection data have to be extrapolated before convolution. Alternatively, very short derivative kernels can be used, generally at a decreased image quality. Kernels of different design and length can be combined.
引用
收藏
页码:728 / 732
页数:5
相关论文
共 50 条
  • [31] Virtual and three-dimensional bronchoscopy with spiral and electron beam computed tomography
    Schoepf, UJ
    Seemann, M
    Schuhmann, D
    Bruning, RD
    Becker, C
    Schwaiblmair, M
    Muller, C
    Knez, A
    Haubner, M
    Krapichler, C
    Gebicke, K
    Vogelmeier, C
    Haberl, R
    Englmeier, KH
    Reiser, MF
    RADIOLOGE, 1998, 38 (10): : 816 - 823
  • [32] A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    Al-Ekrish, A. A.
    Ekram, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) : 67 - 75
  • [33] Effect of pitch, collimation and reconstruction interval on low contrast detectability in spiral computed tomography
    Shumaker, DJ
    McNitt-Gray, MF
    Kimme-Smith, C
    Farahani, K
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 603 - 614
  • [34] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL PHYSICS, 2013, 40 (10)
  • [35] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [36] A Preliminary Investigation of 3D Preconditioned Conjugate Gradient Reconstruction for Cone-Beam CT
    Fu, Lin
    De Man, Bruno
    Zeng, Kai
    Benson, Thomas M.
    Yu, Zhou
    Cao, Guangzhi
    Thibault, Jean-Baptiste
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [37] Oblique surface reconstruction to approximate cone-beam helical data in multi-slice CT
    Chen, LG
    Heuscher, DJ
    Liang, Y
    IMAGE RECONSTRUCTION FROM INCOMPLETE DATA, 2000, 4123 : 279 - 284
  • [38] Multiple mesenteric teratomas: usefulness of spiral computed tomography with 3-dimensional reconstruction
    Okada, T
    Sasaki, F
    Onodera, Y
    Oonishi, S
    Ichikawa, N
    Itoh, T
    Todo, S
    JOURNAL OF PEDIATRIC SURGERY, 2006, 41 (04) : 868 - 871
  • [39] Performance evaluation of oblique surface reconstruction algorithm in multi-slice cone-beam CT
    Chen, LG
    Liang, Y
    Heuscher, DJ
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 952 - 963
  • [40] GPU-based iterative cone-beam CT reconstruction using tight frame regularization
    Jia, Xun
    Dong, Bin
    Lou, Yifei
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13) : 3787 - 3807