Optimization of derivative kernels for exact cone-beam ROI reconstruction in spiral computed tomography

被引:0
作者
Lauritsch, G [1 ]
Sourbelle, K
Tam, KC
机构
[1] Seimens Med Solut, D-91050 Erlangen, Germany
[2] Univ Erlangen Nurnberg, IMP, D-91054 Erlangen, Germany
[3] Siemens Corp Res Inc, Princeton, NJ 08540 USA
关键词
cone-beam computed tomography (CT); cone-beam filtered backprojection (FBP); algorithms; filter design; finite differences; linogram; local region-of-interest (ROI) algorithm; numerical derivative; ringing artifacts; spiral CT; three-dimensional (3-D) radon inversion; windowed filter kernels;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A recent comparison study showed that exact filtered backprojection (FBP)-based solutions of the long object problem are numerically stable and that their image quality is mostly affected by filter design. In this paper, the impact of the kernel design on image. quality is demonstrated systematically in the case of the local region-of-interest (ROI) algorithm. First of all, the implementation is improved by the use of the Linogram technique to eliminate interpolations in the filter step and to speed up computation. In the case of the local ROI method, favorable kernels for one-dimensional (1-D) partial derivatives have to be designed. Finite differences are fast to compute but cause ringing artifacts. More sophisticated kernels can be designed in a straightforward manner in Fourier space, identifying the window function most appropriate to a given application. No ringing artifacts are observed for the windowed kernels under investigation. In addition, windowed kernels are superior to the finite differences regarding the spatial resolution versus noise properties. For partial derivatives in directions with data truncation the projection data have to be extrapolated before convolution. Alternatively, very short derivative kernels can be used, generally at a decreased image quality. Kernels of different design and length can be combined.
引用
收藏
页码:728 / 732
页数:5
相关论文
共 50 条
  • [21] Comparative dosimetry of dental cone beam computed tomography, panoramic radiography, and multislice computed tomography
    Ömer Said Sezgin
    Sadettin Kayipmaz
    Dogan Yasar
    Ahmet Berhan Yilmaz
    Mehmet Halil Ozturk
    Oral Radiology, 2012, 28 : 32 - 37
  • [22] Dual-rotation C-arm cone-beam computed tomography to increase low-contrast detection
    Reshef, Aymeric
    Riddell, Cyril
    Trousset, Yves
    Ladjal, Said
    Bloch, Isabelle
    MEDICAL PHYSICS, 2017, 44 (09) : E164 - E173
  • [23] Cone-beam reconstruction of flat specimens in a super-short scan
    Wang, Xianchao
    Tang, Ziyue
    Zhu, Zhenbo
    Jiang, Chengshun
    INSIGHT, 2015, 57 (10) : 571 - 575
  • [24] Efficient reconstruction from truncated data in circular cone-beam CT
    Wang Xian-Chao
    Yan Bin
    Liu Hong-Kui
    Li Lei
    Wei Xing
    Hu Guo-En
    ACTA PHYSICA SINICA, 2013, 62 (09)
  • [25] Impact of computed tomography (CT) reconstruction kernels on radiotherapy dose calculation
    Vergalasova, Irina
    McKenna, Michael
    Yue, Ning Jeff
    Reyhan, Meral
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 178 - 186
  • [26] A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction
    Dang, Jun
    Gu, Xuejun
    Pan, Tinsu
    Wang, Jing
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (02): : 410 - 418
  • [27] Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT
    Cao, Qian
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Yorkston, John
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20) : 7263 - 7281
  • [28] Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
    Isola, A. A.
    Ziegler, A.
    Schaefer, D.
    Koehler, T.
    Niessen, W. J.
    Grass, M.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2010, 34 (02) : 149 - 159
  • [29] Iterative reconstruction optimisations for high angle cone-beam micro-CT
    Recur, B.
    Fauconneau, M.
    Kingston, A.
    Myers, G.
    Sheppard, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [30] Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization
    Stsepankou, D.
    Arns, A.
    Ng, S. K.
    Zygmanski, P.
    Hesser, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (19) : 5955 - 5970