Determination of manassantin B in rat plasma using a high performance liquid chromatography with fluorescence detection and its quantitative application to pharmacokinetic study

被引:6
|
作者
Lee, Jae-Young [1 ,2 ]
Song, Jae-Hyoung [3 ]
Yoon, In-Soo [4 ,5 ]
Ko, Hyun-Jeong [3 ]
Kim, Dae-Duk [1 ,2 ]
Cho, Hyun-Jong [3 ]
机构
[1] Seoul Natl Univ, Coll Pharm, Seoul 151742, South Korea
[2] Seoul Natl Univ, Pharmaceut Sci Res Inst, Seoul 151742, South Korea
[3] Kangwon Natl Univ, Coll Pharm, 1 Kangwondaehak Gil, Chunchon 200701, South Korea
[4] Mokpo Natl Univ, Coll Pharm, Jeonnam 534729, South Korea
[5] Mokpo Natl Univ, Nat Med Res Inst, Jeonnam 534729, South Korea
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2016年 / 1011卷
基金
新加坡国家研究基金会;
关键词
Manassantin B; Validation; HPLC; Fluorescence detection; Pharmacokinetics; SAURURUS-CHINENSIS; EXTRACT; CELLS; INHIBITORS; LIGNANS; ROOTS;
D O I
10.1016/j.jchromb.2015.12.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive, rapid, and reproducible analytical method of manassantin B in rat plasma by high performance liquid chromatography with fluorescence detection (HPLC-FL) was developed for its application to pharmacokinetic study in rats. Valsartan (VST) was used as an internal standard (IS) in this quantitative analytical method. Manassantin B and VST were extracted by simple and efficient protein precipitation method. Manassantin B was detected at 282/322 nm (excitation/emission) wavelengths using FL detector. The chromatographic separation was obtained with reverse phase C18 column and the mobile phase composed of potassium phosphate buffer containing 0.025% trifluoroacetic acid (pH 2.5; 5 mM) and acetonitrile including 0.025% trifluoroacetic acid (20:80, v/v) at 1.0 mL/min flow rate. The linearity was established at 25.0-10000 ng/mL and the lower limit of detection (LLOD) was 7 ng/mL. The intra- and inter-day accuracy and precision values of manassantin B were within +/- 15% of the theroretical values and <9% from the nominal concentrations, respectively. Accuracy and precision values of manassantin B after stability tests were also within the acceptable ranges. Developed assay was also successfully applied to pharmacokinetic study after intravenous administration of manassantin B in rats. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [11] Determination of Belotecan in the Plasma, Bile, and Urine of Rats by High-Performance Liquid Chromatography with Fluorescence Detection and Its Application to a Pharmacokinetic Study
    Jin, Qing-Ri
    Kim, In-Wha
    Choi, Min-Koo
    Shim, Won-Sik
    Tian, Guang-Yan
    Lee, Soohyun
    Lee, Jonghwa
    Kim, Dae-Duk
    Chung, Suk-Jae
    Shim, Chang-Koo
    ANALYTICAL LETTERS, 2009, 42 (01) : 68 - 83
  • [12] Simultaneous determination of MHD and DMD in dog plasma by high-performance liquid chromatography with fluorescence detection and its application to pharmacokinetic studies
    Li, XY
    Wang, GJ
    Xie, HT
    Wang, R
    Xu, MJ
    Wang, W
    Tao, JN
    Sun, JG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (04) : 958 - 963
  • [13] Determination of wogonin in rat plasma by liquid chromatography and its pharmacokinetic application
    Tsai, TH
    Chou, CJ
    Tsai, TR
    Chen, CF
    PLANTA MEDICA, 1996, 62 (03) : 263 - 266
  • [14] Simultaneous determination of MHD and DMD in dog plasma by high-performance liquid chromatography with fluorescence detection and its application to pharmacokinetic studies
    Xiaoyu Li
    Guangji Wang
    Haitang Xie
    Rui Wang
    Meijuan XU
    Wei Wang
    Jining Tao
    Jianguo Sun
    Analytical and Bioanalytical Chemistry, 2006, 384 : 958 - 963
  • [15] Determination of scopoletin in rat plasma by high performance liquid chromatographic method with UV detection and its application to a pharmacokinetic study
    Xia, Yufeng
    Dai, Yue
    Wang, Qiang
    Liang, Huizheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (02): : 332 - 336
  • [16] Determination of protoapigenone in rat plasma by high-performance liquid chromatography with UV detection and its application in pharmacokinetic studies
    Wei, Anhua
    Zhou, Daonian
    Wu, Guanghua
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1452 - 1456
  • [17] Determination of TJ0711 hydrochloride in rat plasma by high performance liquid chromatography with fluorescence detection and its application to pharmacokinetics
    Fan, Zhaoze
    Si, Luqin
    Xu, Li
    Ma, Yiming
    Hu, Lei
    Qiu, Jun
    Li, Gao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (22): : 2035 - 2038
  • [18] Determination of domperidone in human plasma using high performance liquid chromatography with fluorescence detection for clinical application
    Yoshizato, Tsuneaki
    Tsutsumi, Kimiko
    Kotegawa, Tsutomu
    Imai, Hiromitsu
    Nakano, Shigeyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 86 - 90
  • [19] Determination of Puerarin in Rat Plasma by HPLC with Fluorescence Detection and its Application to Pharmacokinetic Studies
    Luo, Chengfeng
    Yuan, Mu
    Chen, Minsheng
    Liu, Shiming
    Zhu, Liu
    Liu, Xiawen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (03): : 351 - 357
  • [20] Determination of ferruginol in rat plasma via high-performance liquid chromatography and its application in pharmacokinetics study
    Wei, Yuhui
    He, Junquan
    Qin, Hongyan
    Wu, Xin'an
    Yao, Xiaojun
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (10) : 1116 - 1120