The Accuracy of Tests Used to Predict Difficult Airway and a Comparison of Macintosh Laryngoscope to Video Laryngoscope for Intubation

被引:0
作者
Mingir, Tarkan
Kitapcioglu, Dilek
Turgut, Namigar
Yumru, Cengiz
机构
来源
KUWAIT MEDICAL JOURNAL | 2015年 / 47卷 / 03期
关键词
difficult airway; Mackintosh laryngoscope; video laryngoscope; vocal cord; LARYNGEAL MASK AIRWAY; TRUVIEW EVO2;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare TruView EVO2 video laryngoscope (VL) and Macintosh laryngoscope (ML) as regards their success rates in difficult intubation, hemodynamic response and postoperative complications. Design: Prospective study Setting: Training and Research Hospital, Istanbul, Turkey Subjects and Methods: A total of 60 cases were enrolled to the study. Group ML (N = 30) were intubated using ML and Group VL (N = 30) were intubated using TruView EVO2 (TM) VL. Main Outcomes Measures: Cormack-Lehane score was used to evaluate the visualization vocal cords and intubation difficulty. The time required for visualization of vocal cords, total intubation time, difficulty in intubation were also recorded. Results: For all cases, having BMI >30, Mallampati grade > 3, Cormack-Lehane score > 3, short neck, not being able to touch chin to chest, no mandibular protrusion, distance between incisor teeth < 3 cm and, thyromental distance < 7 cm corresponded to the difficult intubation cases of 46.15%. The time period of visualization of vocal cords was significantly longer in Group VL. CormackLehane > 3 and difficult intubation rate was significantly higher in Group ML. The ratio of ones having Mallampati scores of III - IV and Cormack-Lehane scores of I - II was found 17% in Group ML, while the ratio was 30% for Group VL. In all cases, regarding patients having difficult intubation, the success rate of intubation was found as 79.3%. Conclusion: High success rates of intubation were seen with both TruView EVO2 (TM) VL and ML. Either ML or VL can be used in case of difficult intubations.
引用
收藏
页码:201 / 209
页数:9
相关论文
共 17 条
[1]   A comparison of the Truview® blade with the Macintosh blade in adult patients [J].
Barak, M. ;
Philipchuck, P. ;
Abecassis, P. ;
Katz, Y. .
ANAESTHESIA, 2007, 62 (08) :827-831
[2]   CARDIOVASCULAR-RESPONSE TO INTUBATION - A COMPARATIVE-STUDY OF THIOPENTONE AND MIDAZOLAM [J].
BORALESSA, H ;
SENIOR, DF ;
WHITWAM, JG .
ANAESTHESIA, 1983, 38 (07) :623-627
[3]  
Carlino C, 2009, MINERVA ANESTESIOL, V75, P563
[4]   The usefulness of the laryngeal mask airway Fastrach for laryngeal surgery [J].
Chang, Chul Ho ;
Bai, Sun Joon ;
Kim, Mi Kyeong ;
Nam, Sang Beom .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) :20-23
[5]   Validation of a model of graded difficulty in Laerdal SimMan: functional comparisons between Macintosh, Truview EVO2, Glidescope Video Laryngoscope and Airtraq [J].
Darshane, Seema ;
Ali, Mohiidin ;
Dhandapani, Sethuraman ;
Charters, Peter .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (03) :175-180
[6]   Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients [J].
Inal, Mehmet Turan ;
Memis, Dilek ;
Kargi, Murat ;
Oktay, Zumral ;
Sut, Necdet .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (11) :950-954
[7]   The intubating laryngeal mask airway with and without fiberoptic guidance [J].
Joo, HS ;
Rose, DK .
ANESTHESIA AND ANALGESIA, 1999, 88 (03) :662-666
[8]   Comparison of the use of McCoy and TruView EVO2 laryngoscopes in patients with cervical spine immobilization [J].
Joseph, Jiju ;
Sequeira, Trevor ;
Upadya, Madhusudan .
SAUDI JOURNAL OF ANAESTHESIA, 2012, 6 (03) :248-253
[9]   An evaluation of the TruView EVO2 laryngoscope [J].
Li, J. B. ;
Xiong, Y. C. ;
Wang, X. L. ;
Fan, X. H. ;
Li, Y. ;
Xu, H. ;
Ma, Y. ;
Deng, X. M. .
ANAESTHESIA, 2007, 62 (09) :940-943
[10]   Truview video laryngoscope in patients with difficult airways [J].
Matsumoto, Sanae ;
Asai, Takashi ;
Shingu, Koh .
ANESTHESIA AND ANALGESIA, 2006, 103 (02) :492-493