Air-assisted solvent terminated dispersive liquid-liquid microextraction (AA-ST-DLLME) for the determination of lead in water and beverage samples by graphite furnace atomic absorption spectrometry

被引:29
|
作者
Chaikhan, Pilaipan [1 ]
Udnan, Yuthapong [1 ,2 ]
Ampiah-Bonney, Richmond J. [3 ]
Chaiyasith, Wipharat Chuachuad [1 ,2 ]
机构
[1] Naresuan Univ, Dept Chem, Fac Sci, Phitsanulok 65000, Thailand
[2] Naresuan Univ, Fac Sci, Ctr Excellence Petr Petrochem & Adv Mat, Phitsanulok 65000, Thailand
[3] Amherst Coll, Dept Chem, Sci Ctr A205, Amherst, MA 01002 USA
关键词
Solvent terminated dispersive liquid-liquid microextraction; Demulsifier; Pb; Air-assisted; Graphite furnace atomic absorption spectrometry; FLOATING ORGANIC DROP; HEAVY-METALS; ENVIRONMENTAL-SAMPLES; ICP-MS; CADMIUM; PRECONCENTRATION; EXTRACTION; SOLIDIFICATION; TEA; CD;
D O I
10.1016/j.microc.2020.105828
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A preconcentration method based on a novel hybrid air-assisted solvent terminated dispersive liquid-liquid microextraction (AA-ST-DLLME) using a domestic fish-tank pump as a bubble generator was developed for the determination of Pb in water and beverage samples by GFAAS. The important parameters for the microextraction process (pH, concentration of complexing agent, type of extracting solvent, type of disperser, type of demulsifier, air-assisted time, and extraction time) were optimized. Under the optimized conditions, the enrichment factor (EF) of 58.9 was achieved, with the preconcentration factor (PF) of 60.0 and the extraction efficiency of 98.2%. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.025 ng/mL and 0.084 ng/mL, respectively. The relative standard deviation (RSD) was 1.02-3.19%. The proposed method was applied for the determination of trace level of Pb in water, fruit juice, and beverage samples. The spiked recovery at three different spiked concentrations were 82.0-117.3%. Results from the analysis of standard reference materials (SLRS-6) were not significantly different at the 95% of confidence level.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of Cadmium and Lead in Human Teeth Samples Using Dispersive Liquid-liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Zhang, Chunyan
    Wang, Yining
    Cheng, Xiangrong
    Xia, Haibin
    Liang, Pei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (07) : 919 - 924
  • [2] Deep eutectic solvent-based air-assisted liquid-liquid microextraction of lead in gasoline samples followed by graphite furnace atomic absorption spectrometry
    Sorouraddin, Saeed Mohammad
    Farajzadeh, Mir Ali
    Dastoori, Hossein
    Okhravi, Tohid
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (06) : 2591 - 2599
  • [3] Application of Dispersive Liquid-Liquid Microextraction with Graphite Furnace Atomic Absorption Spectrometry for Determination of Trace Amounts of Zinc in Water Samples
    Mazloomifar, Ali
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 2013
  • [4] Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry - Ultra trace determination of cadmium in water samples
    Jahromi, Elham Zeini
    Bidari, Araz
    Assadi, Yaghoub
    Hosseini, Mohammad Reza Milani
    Jamali, Mohammad Reza
    ANALYTICA CHIMICA ACTA, 2007, 585 (02) : 305 - 311
  • [5] Application of microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry for ultra-trace determination of lead and cadmium in cereals and agricultural products
    Ataee, Mari
    Ahmadi-Jouibari, Toraj
    Fattahi, Nazir
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) : 271 - 283
  • [6] Preconcentration and determination of ultra trace amounts of palladium in water samples by dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry
    Shamsipur, Mojtaba
    Ramezani, Majid
    Sadeghi, Marzieh
    MICROCHIMICA ACTA, 2009, 166 (3-4) : 235 - 242
  • [7] Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid-Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Liu, Yaqi
    Han, Quan
    Huo, Yanyan
    Yang, Xiaohui
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2024, 46 (05) : 480 - 490
  • [8] Speciation of As(III) and As(V) in water samples by dispersive liquid-liquid microextraction separation and determination by graphite furnace atomic absorption spectrometry
    Liang, Pei
    Peng, Lili
    Yan, Ping
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 47 - 52
  • [9] Optimization of ultrasound-assisted magnetic retrieval-linked ionic liquid dispersive liquid-liquid microextraction for the determination of cadmium and lead in water samples by graphite furnace atomic absorption spectrometry
    Yao, Li
    Wang, Xie
    Liu, Haitao
    Lin, Chaowen
    Pang, Liangyu
    Yang, Junwei
    Zeng, Qingbin
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2017, 56 : 321 - 326
  • [10] Selective Determination of Lead in Complicated Environmental Samples by Displacement Dispersive Liquid-liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Liang, Pei
    Kang, Caiyan
    Wen, Lijuan
    ATOMIC SPECTROSCOPY, 2016, 37 (01) : 30 - 35