Cardiac Output and Left Atrial Pressure Monitoring by Right Ventricular Pressure Waveform Analysis for Potential Implantable Device Application

被引:3
作者
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Chronic monitoring; hemodynamics; implantable device; signal processing; HEMODYNAMIC MONITOR; HEART-FAILURE; FEASIBILITY; MULTICENTER; HUMANS; SYSTEM;
D O I
10.1109/TBME.2009.2023329
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A well-tested and safe implantable device is now available for long-term ambulatory monitoring of the right ventricular pressure (RVP) waveform of congestive heart failure patients. However, cardiac output (CO) and left atrial pressure (LAP) are more useful for assessing cardiac function and managing volume status. We developed a new technique to estimate relative CO change and LAP by long time interval analysis of the RVP waveform. To demonstrate feasibility, we performed four chronic canine experiments in which the RVP waveform and accurate reference measurements were simultaneously recorded during common hemodynamic interventions. The overall root-mean-squared-errors of the estimated relative CO change and LAP were 16.0% and 2.0 mm Hg. For comparison, the corresponding errors for the previously proposed intra-beat RVP waveform analysis techniques were 21% and 160% higher. With further successful testing, the new technique may potentially be employed with an established implantable device for chronic monitoring of essential hemodynamic variables.
引用
收藏
页码:2335 / 2339
页数:5
相关论文
共 15 条
  • [1] Chuang P P, 1996, J Card Fail, V2, P41, DOI 10.1016/S1071-9164(96)80008-X
  • [2] A system for analysis of arterial blood pressure waveforms in humans
    Karamanoglu, M
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1997, 30 (03): : 244 - 255
  • [3] Karamanoglu Mustafa, 2006, Cardiovasc Eng, V6, P83, DOI 10.1007/s10558-006-9014-4
  • [4] Right ventricular pressure waveform and wave reflection analysis in patients with pulmonary arterial hypertension
    Karamanoglu, Mustafa
    McGoon, Michael
    Frantz, Robert P.
    Benza, Raymond L.
    Bourge, Robert C.
    Barst, Robyn J.
    Kjellstrom, Barbro
    Bennett, Tom D.
    [J]. CHEST, 2007, 132 (01) : 37 - 43
  • [5] Ljung L., 1987, System Identification:Theory for the User
  • [6] Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
    Lu, Zhenwei
    Mukkamala, Ramakrishna
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (02) : 598 - 608
  • [7] Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor:: A multicenter, 12-month follow-up study of patients with chronic heart failure
    Magalski, A
    Adamson, P
    Gadler, F
    Böehm, M
    Steinhaus, D
    Reynolds, D
    Vlach, K
    Linde, C
    Cremers, B
    Sparks, B
    Bennett, T
    [J]. JOURNAL OF CARDIAC FAILURE, 2002, 8 (02) : 63 - 70
  • [8] Continuous cardiac output monitoring by peripheral blood pressure waveform analysis
    Mukkamala, R
    Reisner, AT
    Hojman, HM
    Mark, RG
    Cohen, RJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 459 - 467
  • [9] MULLIGAN LJ, 2004, Patent No. 1341439
  • [10] Noordergraaf A., 1978, CIRCULATORY SYSTEM D